Model: | TY-LR87 |
---|---|
Brand: | TianYing |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Electronic Measurment Apparatus |
Label: | laser rangefinder , laser range finder , rangefinder |
Price: |
-
|
Min. Order: | 3 pc |
Live Chat: | Last Online:17 May, 2024 |
China TianYing TY-LR87 1570nm 25km eye safe laser rangefinder module of 5 Hz fulfils as independant sensor unit the requirements of modern optronic reconnaissance and target tracking systems that require a high repetition rate of measured ranges from fast moving targets.
Depending on weather conditions, measurement frequency of 5 Hz can be up to a few minutes, measuring accuracy is 1m, working high temperature is +70ºC.
The LRF-25km leveraged the lastest technology to construct this remarkably compact, exceptionally accurate rangefinder, hence customer enable very easy integration into ships, land vehicles or aeroplanes platforms, inclduing camera system, fire-control system etc.
25km 5Hz continuous 1570nm Eye Safe Laser Rangefinder Features:
1) Typical ranging capability up to 25km of 5Hz.
2) Variable repetition rate up to 5 Hz continuous at +60ºC.
3) Range accuracy < +/-1 m for target ranges.
4) Option fan air flow cooling.
5) ANSI Z136.1-2007/ICE 60825-1:2007 Class 1M or Class 3R Eye-Safe.
6) Miniaturized design, weight 2.5 kg with house.
25km 5Hz continuous 1570nm Eye Safe Laser Rangefinder Recommended Use:
1) Optronic surveillance and reconnaissance.
2) Target tracking systems and anti-aircraft systems.
3) Fire control systems for land, air and sea targets.
4) For determination of flight altitudes on airports.
5) To measure the distance of ships from the coast.
6) In general for applications of position determination of dynamic objects.
25km 5Hz continuous 1570nm Eye Safe Laser Rangefinder Mainly Specification:
Model | TY-LR87 |
Transmitter | |
Laser Type | OPO |
Wavelength | 1570nm |
Measuring rate(programmable) | 5Hz work 30 seconds and rest 30 seconds cycle at +60ºC. |
Pulse energy | ≥12mJ |
Beam divergence | ≤ 1 mrad, typical 0.8mrad, option 0.5mrad. |
Laser classification | 1M or 3R |
Extinction Ratio | >47 dB (85% reflectivity at 500m target) |
Cooling | Option fan air flow. |
Receiver | |
Detector | Avalanche Photo Diode Detector (APD). |
Range data | |
Ranging capability | 25km of building/large craft in 23.5km visibility; |
≥ 13km of 30% albedo 5m² aircraft in 23.5 km visibility(normal 14.5km). | |
Accuracy | ≤ +/-1m |
Electrical interface | |
Data interface | RS422 |
Power | 20 - 30V DC |
Environmental conditions | |
Operation Temperature | -40ºC~+70ºC |
Mechanical interface | |
Size | ≤ 2000 cubic centimeters |
Weight | ≤ 2.5kg with house |
* - Note | *Product design and Technical information is subject to change without notice
** Depending on the region of sale. |
Question:
1, Why many 20km/30km/40km laser rangefinder can not measure tank 10km in standard 23.5km visibility?
Because their 20km/30km/40km is theory data or high reflection large target in ideal visibility condition, even reflection need beyond 80% and visibility need beyond 50km.
2, Why many NATO target 10% reflection 12km laser rangefinder can not measure tank 10km in standard 23.5km visibility?
Because their 10% reflection is not real performance data, 2.3m x 2.3m NATO target is not real tank, or their NATO target effective size is different; normal 2.3m x 2.3m target real albedo is 50% or more.
About test land standard, normal big target typical 20km LRF with 25km visibility, then, normal this LRF can measure 2.3m x 2.3 target about 15km or more, then, 30% albedo 2.3m x 2.3m target is about 10km ~ 12km.
Also, starting state and stable state measuring range is different too, such as 15mJ-25mJ LRF, starting state is 25mJ, typical stable state is only 15mJ, only many companies are only said starting state, for example, said single pulse laser energy is at least 25mJ.
3, Why many laser rangefinder do not show measurement rate details?
Because max rate and continuous rate technology demand is different, such as max 12.5Hz 10 sec to 60 sec, maybe then 5Hz is max 1 min to 3 min with cycle.
Also, when rate have more different, such as 1Hz-5Hz, 1Hz-10Hz, 1Hz-20Hz, 5Hz-25Hz etc, then their working distance have more different too.
About 1.5µm eye safe laser rangefinder, if 1Hz is 10km, then, normal 5Hz is only balance about 80%~ 85%, normal 10Hz is only balance about 70%~80%, when this LRF laser energy is very low, then attenuation speed will accelerate.
4, Why normal mid-long range high rate laser rangefinder do not use for Erbium-glass laser?
Because normal Erbium-glass laser energy is too low, high rate continuous measuring time is too short, especially at extreme operating temperatures.
In fact, if Erbium-glass laser want to meet demand, energy need at least 2mJ, normal need 5mJ to 8mJ.
Then, Erbium-glass is not competitive with OPO and Raman shifted.
5, Why many laser rangefinder price is very cheap?
Because performance is different, for example: one LRF is used for bad cable, messy interface, messy wiring etc, then the LRF cost can reduce, even reduce much, but no warranty on performance.
If used for same performance, then our price is very cheap. that is why many laser rangefinder do not show their real main performance data.
Embed HTML Code: |
HD800 2MP 12.5mm~800mm coaxial zoom no chromatic aberration CCTV camera see 19km house and communication pole with NIR SWIR HD800 2MP 12.5mm~800mm coaxial zoom no chromatic aberration CCTV camera see 6km rock and light pole with NIR SWIR HD800 2MP 12.5mm~800mm coaxial zoom no chromatic aberration NIR CCTV camera see 40km lighthouse(42km) on the islands, we have done simultaneous field tests, many 1000mm and 1200mm focal length lens plus 2x extender CCTV cameras can not see this island with the disance, including famous brands, then do not mention the lighthouse too, only their price is cheap. Hig accurate coaxial zoom defog surveillance security CCTV camera align target with NIR |
---|---|