Model: | GDGS |
---|---|
Brand: | GOLD |
Origin: | Made In China |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | factor tester transf , Dielectric Loss Tang , transformer power fa |
Price: |
US $568
/ pc
|
Min. Order: | 1 pc |
Live Chat: | Last Online:22 Apr, 2021 |
Introduction
1. GDGS Automatic Transformer Power Factor Tester, Transformer Tan Delta Tester is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in.
2. It can also supply high voltage source for testing.
3. Frequency can be changed to 50Hz, 47.5Hz\52.5Hz、45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz; thus, it can avoid interference of power frequency.
Auto./manual |
Fully- automatic |
Accuracy |
Cx: t(1%RDG+5pF) |
PF: t(1%RDG+0.04%) |
|
Capacitance range |
Internal HV: 3pF~ 60000pF/ 10kV, 60pF~1uF/ 0.5kV |
External HV: 3pF~0.3uF/10kV |
|
Resolution: 0.0001pF, 4 digital |
|
Interference ratio |
Interference current is no more than 2 times of the test current |
PF range |
No limit, resolution 0.001%, C/L/R specimen test |
Input current range |
10uA-1A |
Internal HV |
0.5-10kV / 200mA (max) |
HV accuracy |
±(reading*1%+ 10V) resolving 1V |
Frequency select |
60Hz single point, locked |
55Hz/65Hz double point, locked |
|
Test time |
40S typical |
Power supply |
180V~270V 50Hz/ 60Hz auto |
Dimension |
550*490*580mm |
Specification
Introduction
Features:
Simple operation, the instrument is equipped with a high-end full touch LCD screen, super touch interface, each process is very clear, the operator does not need additional professional training can be used. Click on it to complete the whole process of measurement, is a very ideal intelligent dielectric loss measurement equipment.
The instrument is equipped with a calendar chip and large capacity memory, the test results can be stored in chronological order, at any time to view the history, and can print output.
The instrument can use high pressure, high voltage, standard, standard, positive connection method and reverse connection method, self excitation method and other methods can do testing; high voltage in standard high voltage conditions (greater than 10kV) dielectric loss.
The instrument can also test the full sealed CVT (capacitor voltage transformer) C1, C2 dielectric loss and capacitance, to achieve the C1, C2 simultaneous test. The instrument can also test the CVT ratio and voltage angle difference.
The instrument can accurately measure the dielectric loss and capacitance of CVT without dismantling the CVT high voltage lead.
The instrument can be used to measure the dielectric loss and capacitance value of C0 on the upper end of CVT.
The inverter and sampling circuit of the instrument are all controlled by digital, and the output voltage is adjustable continuously.
The instrument has many protection measures, such as input voltage fluctuation, output short circuit, over voltage, over current and temperature. The instrument also has the grounding detection function to ensure that no grounding equipment is not allowed to boost.