The original quality goods OMRON E2EH X3D1 -- T
Product Description
Dc line 2 (E2EH - / X/D) Size M12M18M30 Shielding shielding Project model E2EH X3D/E2EH - X7D mind E2EH - X12D 3 mm7mm12mm detection distance Set distance * 10 ~ 2.4 mm0 mm0 ~ 5.6 ~ 5.6 mm Should be differential detection distance is less than 15% Magnetic metal detectable objects (non-magnetic metal detection distance is shorter.) Standard testing objects iron 12 * 12 * 1 mm iron 21 * 21 * 1 mm iron 36 * 36 * 1 mm * 2500 hz300hz100hz response frequency Power supply voltage (using the voltage range) DC12 ~ 24 v ripple (p - p) below 10% (DC10 ~ 32 v but above 100 ℃, the maximum 24 v) Leakage current 0.8 mA Control switch output capacity of 3 ~ 100 ma, + 100 ~ + 110 ℃ for 3 ~ 50 ma.* 3 polar residual voltage type: 3 v below, nonpolar (E2EH - X/D/T) for the below 5 v * 3 (when load current is 100 ma, cable 2 m long) Lamp type D1: action (red), set to display (yellow), D2: action show (yellow) Mode of action (close to the test object) D1 type: NO, D2 type: NC, for details please see the Catalog of "input and output circuit diagram" sequence diagram Surge protection circuit of absorption, load short circuit protection When environmental temperature range: 0 ~ + 100 ℃ (0 ~ + 110 ℃, 1000 hours) * 4 Save: 25 ~ + 70 ℃ (without freezing and condensation) : work environment humidity range, save time by 35 ~ 95% RH (no condensation) The influence of the temperature of 0 ~ + 70 ℃ temperature range of detection distance change is within plus or minus 10% at 23 ℃, + 70 ~ + 100 ℃ temperature range change detection distance is within plus or minus 15% at 23 ℃, + 100 ~ + 110 ℃ temperature range change detection distance is within 15% ~ + 20% at 23 ℃ The influence of the voltage at the rated supply voltage range of plus or minus 15%, ratedImpact (durable) 1000 m/s2 X, Y, Z direction 10 times each IEC standard IP67 protection structure, standard IP69K DIN40050-9 * 5 Connection wire draw out type (standard cable 2 m long), plug and socket type The quality (after packing) wire leads to about 80 g, 145 g, 220 g Connectors, about 30 g about 55 g 125 g Material shell, fastening nut (SUS316L stainless steel) Test surface of PBT, Conductor heat-resisting PVC (wire drawn type) Attachment specification
Product Image
Send Inquiry to this Member
Related Products of this Company
This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please
click here.
China Suppliers Quick Searching:
,