.Introduction
ETCR4000A Intelligent Double Clamp Digital Phase Volt-Ampere Meter is a well-developed full-automatic, multi-functional, digital, intelligentmeter specifically designed for field testing, which is a overall upgrade product based on mechanical knob phase volt-ampere meter, can simplify operation and reduce the possibility of misoperation, featuring high accuracy, high stability, low power consumption, easiness to use and so on. It can directly measure AC voltage and AC current without opening the measured circuit, phases between three voltages, three currents and phase between the voltage and current; in addition, the power factor and power of the circuit can be indirectly measured, it can also be used to distinguish three-phase sequence, transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc. Applyto electric power, petroleum chemical industry, metallurgy, railway, and meteorology, industrial and mining enterprises, scientific research institutions, measuringsector and so on, especially for the electricity billing system and relay protection system, and electricity measurement, electricity check, power inspection for power marketing department. Assembling, relay protection, differential detection, start experiment, substation overhaul, or power practical training, skills match for biotech department.
ETCR4000A Intelligent Double Clamp Digital Phase Volt-Ampere Meter has well designed shell mould made of newest material, attaches with shakeproof, skidproof, high insulation sheath, has a 240dots×160dots LCD screen, all the test data display on the screen simultaneously, vector diagram indication, and looks exquisite and comfortable. Meter equipped with USB-RS232 interface, can store 500 sets of data, through the system software upload stored data to the computer, implementing online real-time monitoring and historical inquires, dynamic display. Can read, save, report, print history data, etc. Its small mouth clamps are suitable for line densely places.
.Technical Specifications
1Base Conditions and Working Conditions
Influence Quantity
Base Condition
Working Condition
Remark
Ambient Temperature
23±1
-1040
----
Ambient Humidity
40%60%
80%
----
Signal Waveform
sine wave
sine wave
β=0.01
Signal Frequency
50HZ±1HZ
45HZ65HZ
----
Meter Working Volt
9V±0.1V
9V±1.5V
----
Current Amplitudein Phase/Frequency/Phase Sequence Test
1A±0.2A
2mA20A
----
Voltage Amplitudein Phase/ Frequency/ Phase Sequence Test
100V±20V
10V600V
----
Current Amplitudein Power / Power Factor Test
1A±0.2A
20mA20A
----
Voltage AmplitudeinPower / Power Factor Test
100V±20V
10V600V
----
External ElectricMagnetic Field
To be avoided
Measured Wire Position
Measured wire at approximately the geometric center of the clamp
2Intrinsic Error and Performance Indicators under Base Conditions
Category
Measurement Range
Resolution
Intrinsic Error
Voltage
AC 0.0V600V
0.01V
±(1.5%rdg+3dgt)
Current
AC 0.0mA20.0A
0.1mA
±(1.5%rdg+3dgt)
Phase
0.0°360°
0.
±1°
Active Power
0.0W12kW
0.1W
±(3%rdg+3dgt)
Reactive Power
0.0VAR12kVAR
0.1VAR
±(3%rdg+3dgt)
Apparent Power
0.0VA12kVA
0.1VA
±(3%rdg+3dgt)
Frequency
45HZ65HZ
0.01HZ
±(2%rdg+3dgt)
Power Factor
-1+1
0.001
±0.03
3General Specification
Function
Simultaneous measurement of two AC voltage, current, phase between voltage, phase between current, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, distinguish transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc.
Power
DC9V alkaline batteries1.5V AA×6
Consumption
About 70mA at most with enabled backlight, battery working continuously for about 14 hours
About 40mA with disabled backlight, battery working continuously for about 20 hours
Display Mode
LCD display, 240dots×160dots
Meter Size
Length, Width, Height196mm×92mm×54mm
acuminate current clamp:7.5mm×13mm
Measurement Range
(automatic shift)
AC Voltage0.00 V600V (automatic shift)
AC Current0.0mA20.0A (automatic shift)
Phase0360°
Frequency45.00Hz65.00Hz
Active Power0.0W12kW
Reactive Power0.0W12kVAR
Apparent Power0.0W12kVA
Power Factor-1+1
Resolution
VoltageAC 0.01V
CurrentAC 0.1mA
Phase0.1°
Frequency0.01Hz
Active Power0.1W
Reactive Power0.1VAR
Apparent Power0.1VA
Power Factor0.001
Sample Rate
About 2 times/second
Data Hold
Press HOLD key to keep data, "DH" symbol appears
Data Storage
1500 sets
RS232 Interface
USB-RS232 interface, download data to computer for analysis and management
Automatic Shutdown
Automatic shutdown about 15 minutes later after launching to reduce battery consumption
Backlighting
Suitable for dark place and nightly use
Voltage Detection
Low battery symbol “      " appears to remind the replacement of battery when the battery voltage drops below 7.2V.
Weight
Main Unit about 550gwith battery),acuminate current clamp about 170g×3, round current clamp about 1853, test line about 250g
Test Line Length
1.5m
Current Clamp Length
2m×φ5mm
Working Temperature and Humidity
-1040 below 80%Rh
Storage Temperature and Humidity
-1060 below 70%Rh
Input Impedance
Testing voltage the input impendence is 2MΩ
Withstand Voltage
Withstand 1000V/50Hz sine wave AC voltage for 1 minute between the meter lines and shell; Withstand 500V/50Hz AC voltage sine wave for 1 minute between the two voltage inputs
Insulation
≥100MΩbetween meter lines and shell or between the two voltage inputs
Structure
Double insulation, with insulation vibration-proof sheath
Safety Specifications
IEC61010-1 CAT 600V, IEC61010-031, IEC61326, 2 class of pollution
Accessories
Main Unit: 1 pc; Meter Box: 1 piece; Current Clamp: 3 pcs; Test Line: 4 pcs(2 yellow, 2black); RS232 Data Line: 1 pc; Disk: 1 pc; Battery: 6 pcs(alkaline dry battery: 1.5V AA); User Manual: 1 pc; Guarantee Card: 1 pc; Certification: 1 pc.

Product Image

ETCR4000A Intelligent Double Clamp Digital Phase Volt-Ampere Meter 1
Img 1

Send Inquiry to this Member

Guangzhou ETCR Electronic Technology Co., Ltd.

F-3F, No.4 Pengshang Zhifu Road, Jiahe, Baiyun District, Guangzhou, Guangdong, 510440, China.

Phone:
86-020-62199554
Fax:
86-020-62199551
Contact:
James Vu (Sales Assistant)
Mobile:
62199554

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Electricity Meter & Instrument Made In China Products

,  

Electricity Meter & Instrument China Suppliers and China Manufacturers