Home > Products > Electronics & Electricity > Electronic Instrument > Electronic Measurment Apparatus

600000 Counts, True RMS, dual display, 4-wire Measurement digital multimeter 1600000 Counts, True RMS, dual display, 4-wire Measurement digital multimeter 2600000 Counts, True RMS, dual display, 4-wire Measurement digital multimeter 3
  • 600000 Counts, True RMS, dual display, 4-wire Measurement digital multimeter 1
  • 600000 Counts, True RMS, dual display, 4-wire Measurement digital multimeter 2
  • 600000 Counts, True RMS, dual display, 4-wire Measurement digital multimeter 3

600000 Counts, True RMS, dual display, 4-wire Measurement digital multimeter

Model:HT5156
Brand:HENKI
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Electronic Measurment Apparatus
Label:dmm , multimeter , digit
Price: -
Min. Order:1 pc
Inquire Now Add to Basket

Member Information

Detail

HENKI TECH CO., Ltd.

Free MemberTaiwan, China
Live Chat:Last Online:24 Mar, 2014

Product Description


The HT5156 is a bench-type, dual-display digital multimeter with a price well worth its value. It provides a broad range of features and measurement functions which meet various requirements in manufacturing and R&D environments.


 


The 600000 counts HT5156 provides real-time measuring and readback function. It also features high brightness/contract VFD, 4-wire resistance measurement technique and 0.02% DCV measuring accuracy.


 


 


For those who need to control and take preset measurements with a PC, the built-in USB and RS-232C interfaces provide an easy connection between the PC and DMM. The USB and RS-232C interfaces can be controlled remotely via industry standard SCPI commands, which ensure an easy integration with different programming environments.


 


Product Features:


1. 600000 Counts Display


2. 22 Built-in Measurement Functions: DCV, ACV, DC+ACV, DCI, ACI, DC+ACI, 2Wohm, 4Wohm,Diode Test, Continuity Beeper, Capacitance, Frequency, Period. %Duty Cycle, Temperature, dB, dBm, Math(MX+B, %, 1/X), MAX/MIN, Auto Hold, REL, Compare


3. Auto or Manual Ranging


4. VFD Dual Display


5. 0.02% DCV Accuracy


6. ACV Measuring Frequency Up to 100KHz


7. Current Measurement Range with High Energy Fuse Protection


8. AC or AC+DC True RMS


9. 2000 Points Data-Logging Function


10. Selectable Measurement Rate


11. External Trigger Function


12. Standard RS-232C and USB interface


13. Option: GPIB(IEEE-488.2) interface


 


Electrical Specifications


Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23°C ± 5°C & less than 75% relative humidity.


True RMS voltage & current accuracies are specified from 5 % to 100 % of range or otherwise specified. Maximum Crest Factor < 1.8:1 at full scale & < 3.6:1 at half scale, and with frequency components within the specified frequency bandwidth for non-sinusoidal waveforms.


  


DCV 


Range                                                            Accuracy


600.000 mV, 6.00000V, 60.0000V                 0.02%+20d


600.000V                                                             0.04%+20d


1000.00V                                                             0.05%+20d


Input Impedance: 10MW


 


DC Current


Range                                              Accuracy                               Burden Voltage


600.000mA                                     0.15%+200d                        0.11mV/mA(typical)


6000.00mA                                     0.1%+200d


60.0000mA                                     0.15%+200d                         1.8mV/mA(typical)


600.000mA                                     0.15%+300d


6.00000A                                                0.5%+200d                           26mV/A(typical)


10.0000A 1)                                    0.5%+200d


 1) ≤10A continuous, >10A ~ 20A for 30 second max with 5 minutes cool down interval


 


True RMS AC & AC+DC Voltage 


Range                                                      Accuracy 1)


20Hz -- 45Hz


600.000mV, 6.00000V, 60.0000V          1.5%+600d


600.000V, 1000.00V                               Unspec'd


45Hz -- 300Hz


600.000mV                                             0.3%+200d


6.00000V, 60.0000V                               0.8%+200d


600.000V, 1000.00V                               0.4%+400d


300Hz -- 5kHz


600.000mV                                            0.3%+100d


6.00000V, 60.0000V, 600.000V            0.4%+400d


1000.00V (@ 300Hz ~ 1kHz only)     0.8%+400d


5kHz -- 20kHz


600.000mV                                     0.5%+200d


6.00000V, 60.0000V                       0.8%+200d


600.000V                                                0.5%+200d


1000.00V                                                Unspec'd


 


20kHz -- 100kHz


600.000mV                                     2.5%+400d


6.00000V, 60.0000V                       4.0%+400d 2)


600.000V                                                Unspec'd


1000.00V


1) From 5% to 10% of range: accuracy % of reading (or in dB) + 1800d


2) From 10% to 15% of range: accuracy % of reading (or in dB) + 1000d


Input Impedance: 10MW, 50pF nominal (80pF nominal for 500mV range).


 


True AC & AC+DC Current


Range                                     Accuracy                                 Burden Voltage


50Hz – 60Hz


600.000mA                             0.5%+500d                             0.11mV/mA(typical)


6000.00mA


60.0000mA                                                                             1.8mV/mA(typical)


600.000mA


6.00000A                                                                                        26mV/A(typical)


10.0000A 1)


40Hz – 1kHz


600.000mA                             0.7%+500d                           0.11mV/mA(typical)


6000.00mA


60.0000mA                                                                             1.8mV/mA(typical)


600.000mA


6.00000A                                                                                        26mV/A(typical)


10.0000A 1)


1kHz – 10kHz


600.000mA                             2.0%+500d                           0.11mV/mA(typical)


6000.00mA


60.0000mA                                                                             1.8mV/mA(typical)


600.000mA


6.00000A                                                Unspec'd                       26mV/A(typical)


10.0000A 1)


1) ≤10A continuous, >10A ~ 20A for 30 second max with 5 minutes cool down interval


 


Ohms (2W, 4W)


Range                                                      Accuracy


600.000W                                               0.07%+20d


6.00000kW


60.0000kW                                             0.1%+20d


600.000kW


6.00000MW                                            0.5%+60d


60.0000MW                                            2.0%+60d


Open Circuit Voltage: 1.2VDC typically (3VDC typically for 500W range)


1)From 0% to 10% of range: Specified accuracy + 30d


 


Diode Tester


Range                      Accuracy               Test Current                 Open Circuit Voltage 


2.00000V                1%+10d                 0.4mA (Typical)            3.5 VDC (Typical) 


 


Continuity Beeper


Range                                                      Accuracy 


600.000W                                               0.07%+90d+xW


 


Capacitance


Range                            Accuracy 1)


60.000nF                         0.8%+30d


600.00nF                         0.8%+30d  


6.0000mF                        1.5%+30d


60.000mF                        2.5%+30d


600.00mF                        3.5%+50d


9.9999mF                        5.0%+50d 


 1) Accuracies with film capacitor or better


 


Hz Line Level Frequency


Function Range           Sensitivity (Sine RMS)             Measurement Range


600mV                                100mV                                          10Hz ~ 200kHz


6V                                          0.6V                                              10Hz ~ 200kHz


60V                                        6V                                                 10Hz ~ 100kHz


600V                                      60V                                               10Hz ~ 100kHz


1000V                                    600V                                             10Hz ~ 10kHz


600mA, 6000mA                 300mA                                          10Hz ~ 10kHz


60mA, 600mA                      30mA                                            10Hz ~ 10kHz


6A, 10A                                  3A                                                  10Hz ~ 3kHz


Accuracy: 0.02%+4d


  


Hz Logic Level Frequency 


Range                                                                      Accuracy


5.0000Hz--1.00000MHz                                         0.002%+4d 


Sensitivity: 2.5Vp square wave


 


%Duty Cycle


Range                                                                      Accuracy


0.100% -- 99.990%                                                 3d/kHz+20d


Input Frequency: 5Hz -- 500 kHz, 5V Logic Family


 


Temperature


Range                                                                      Accuracy


-100.0°C to 1000.0°C                                             0.3%+1.5°C


-148.0°F to 1832.0°F                                              0.3%+3.0°F


Thermocouple range & accuracy not included


 


Math Functions


dB, dBm, Math(MX+B, %, 1/X), Max/Min(Max, Min, Max-Min, Avg),


REL, Hold, Compare, Filter, Store, Recall


Display                                                           5x7 dot matrix VFD Display


Interface                                                        Standard RS-232,USB. Optional GPIB(SCPI)


Power Source                                               AC100/110/220/230V,±10%,50/60Hz


Dimension & Weight                                    262(W)x104(H)x367(D)mm, Approx. 4.4Kg


Order Information


HT5156                                                           600,000 Counts Dual Display Digital Multimeter


Opt-01                                                             GPIB(IEEE-488.2) Interface


Product Image

600000 Counts, True RMS, dual display, 4-wire Measurement digital multimeter 1
Img 1
600000 Counts, True RMS, dual display, 4-wire Measurement digital multimeter 2
Img 2
600000 Counts, True RMS, dual display, 4-wire Measurement digital multimeter 3
Img 3

Send Inquiry to this Member

HENKI TECH CO., Ltd.

11F., NO 27, LN. 1, YI-AN RD., ZHONGHE DIST., NEW TAIPEI CITY, TAIWAN

Phone:
886-2-29481208
Fax:
886-2-29481209
Contact:
Sean Yang (Sales Manager)
Mobile:
922028981

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Electronic Measurment Apparatus Made In China Products

,  

Electronic Measurment Apparatus China Suppliers and China Manufacturers