Introduction
HPC518 is the world's first three power can be supplied directly using a portable exhaust gas analyzer. Particularly applicable to monitoring of environmental protection, public security, traffic department road check sampling; inspection departments, industrial and mining enterprises in wild and lonely without power supply can be used. At any time, real time, without any place and have no power can be detected. Apparatus for refining aluminium alloy rod box shell, convenient carrying, simple operation.
The apparatus according to the national standard GB18285-2005 " ignition engine exhaust emission limits and methods of measurement ( double idle speed and simple driving mode " )and development of a test apparatus. We determine the technical indicators, also referring to the people's Republic of China communications industry standard JT/T386-2004 " auto emissions tester technical conditions " and other standards. Apparatus suitable for gasoline, liquefied petroleum gas ( LPG ), CNG and alcohol as fuel of engine emission measurement. This product is the use of German imports of movement, science and technology developed by. The performance stability, reliability are in line with international standards ISO3930 or OIML R99 0 level precision. The apparatus with a single idle, idle, double ASM condition measurement.
Main function
1.Use of liquid crystal display,English menu, can display HC, CO, CO2, O2, NOx ( NO+NO2 ),λ, COcor and speed, oil temperature, flow, pressure data.
2. Automatic zero adjustment,automatic temperature compensation, automatic oil-water separator.
3.Adopts imported German O2 infrared detectors, sensors and NOX sensors, vibration resistance, good stability, high accuracy.
4. Can be equipped with automatic built-in printer interface, RS-232A ( or 0-5V simulation interface ).
5.Self-diagnosis, fault when prompted, until the troubleshooting can continue measurement.
6.With time function, can display minutes and seconds, year, month, day, print.
7.With HC residues inspection, automatic cleaning gas leak detection.
8.When measuring instantaneous value end show and print concentration, average /maximum/Minimum value.
9.Can enter the number plate of the car, and can store 2000 cars measurement data, for ready retrieval printing.
10.With single, double idle idle measurement measurement, general measuring three kinds of measurement.
11.With a speed, oil temperature measurement channel.
12.Built-in rechargeable batteries for 8 hours of continuous work.
13.With 220V charger, car cigarette lighter power supply plug and battery holder.
Technical parameters
Item |
Date |
Measuring range
|
HC:0-10000 ×10-6 (ppm)vol ( petrol, hexane equivalent ) Or C3H8: 0-20000 ×10-6(ppm)vol ( liquefied petroleum gas as fuel, propane equivalent ) CO:0 ~ 10× 10-2 (% ) vol CO2:0~20 ×10-2 (% ) vol O2:0~25 × 10-2 (% ) vol NOx:0~5000 ×10-6 ( ppm ) vol λ: 0.5~1.5 COcor:0 ~10× 10-2 (% ) vol R.M.P:0-9999r.m.p OIL TEMP:0-150 ℃ |
Indication error |
HC ± 10× 10-6 (ppm)vol (absolute error ) or± 5% ( relative error) CO ± 0.03× 10-2 ( % )vol (absolute error ) or± 5% ( relative error) CO2 ± 0.5× 10-2 ( % )vol (absolute error ) or± 5% ( relative error) O2 ± 0.1× 10-2 ( % )vol (absolute error ) or± 5% ( relative error) NOx ± 25× 10-6 (ppm)vol ( absolute error ) or± 4% ( relative error) The above error in one of the requirements to meet. |
Repeatability |
Repetition error≤+/- 2% |
Stability |
Automatic zero, moment drift less than≤±3% |
Resolution |
HC:1×10-6(ppm)vol CO:0.01×10-2(%)vol CO2:0.1×10-2(%)vol O2:0.01×10-2(%)vol NOx:1×10-6(ppm)vol λ:0.01 |
95% repose time no more than 10 seconds |
|
8min ( Emergency detection can be preheated 3 min) |
|
Output Mode |
Can display, print gas concentration maximum value, average value, the minimum value of the license plate number, test time, date, speed, temperature and COcor value of lambda,, can interface with computer networking |
Environmental conditions |
Temperature-5 ~ 50 ℃, relative humidity ≤90% |
Service Time |
The oxygen sensor and the nitrogen oxygen sensor in air in life expectancy for two years and 14 months. ( over the duration of accuracy will drop ) |
Power |
Built-in battery powered directly use By an on-board DC12V direct power use (without any power supply inverter ) AC100-240V 50/60HZ |
Power |
<50VA |
Dimensions |
520mm (L)× 360mm ( W)× 250mm (H) |