Model: | HPC508 |
---|---|
Brand: | STARK |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Analysis Instrument |
Label: | gas detector , carbon monoxide dete , vehicle emission tes |
Price: |
-
|
Min. Order: | 1 pc |
Live Chat: | Last Online:22 Nov, 2014 |
Introduction
1. HPC-508 automobile exhaust analyzer can be applied to steady-state condition method (ASM method) and simple transient conditions France (Vmas) system equipment package, is a simple method for vehicle inspection conditions dedicated analytical instruments.
2. Equipped with imported professional detector, according to the U.S. BAR-97 with the relevant requirements for the design and manufacture to meet the latest national standard GB18285-2005 in the steady-state condition method of measurement standards and accuracy requirements, measure CO, HC, CO2, O2, NO , λ, and AFR, engine speed, oil temperature, a wide range of standard gas entrance, automatic cleaning function, to meet the Beijing local standards and national standards relating to use requirements.
3.Can also be widely used in motor vehicle exhaust pollution analysis of continuous testing, engine emission analysis studies.
Main Features
1.High-precision, high resolution, the instrument to meet the European I-IV standard emissions testing of vehicles.
2.Auto-zero, automatic cleaning, automatic temperature compensation, pressure compensation.
3.Have the gas line leak inspection, traffic monitoring, HC residue testing, cleaning gas sampling tube cleaning path.
4.With ASM method, pairs of test and normal idle speed idle test a variety of measurement mode, engine speed, oil temperature, and other parameter measurement function.
5.License plate number can be entered and the 2000 set of data storage, reference function, clock display.
6.Can choose long life and high precision infrared (NDIR) NO analysis platform, the reaction rate than the traditional three times faster electrochemical detection principle.
Technical Parameter please see the next page
Item |
Date |
Measuring range
|
HC:0~10000×10-6(ppm)vol CO:0~10×10-2(%)vol CO2:0~20×10-2(%)vol O2: 0~25×10-2(%)vol NOx:0~5000×10-6(ppm)vol λ:0.50~3.00 COcor:0~10×10-2(%)vol Lambda : 0.5~1.5 R.M.P: 0-9999r.m.p OIL TEMP:0-150℃ |
Indication error |
HC: 0 ~ 2000 (ppm) vol±4×10-6(ppm) vol (absolute error) ±3%(relative error) 2001~5000(ppm)vol±4×10-6(ppm) vol (absolute error) ±5%(relative error) 5001 ~ 9999 (ppm) vol ±4×10-6(ppm) vol (absolute error) ±10%(relative error) CO:0 ~ 10.00 (%) vol ±0.02×10-2 (%) vol (absolute error) ±3%(relative error) 10.01 ~ 14.00 (%)vol±0.02×10-2 (%) vol (absolute error) ±5%(relative error) CO2:0 ~ 16.0 (%)vol ±0.3×10-2 (%) vol (absolute error) ±3%(relative error) 16.1 ~ 18.0(%)vol ±0.3×10-2 (%) vol (absolute error) ±5%(relative error) O2:0 ~ 25.00 (%) vol±0.1×10-2 (%) vol (absolute error) ±5%(relative error) NO:0 ~ 4,000 (ppm)vol±25×10-6(ppm) vol (absolute error) ±4%(relative error) 4001~5000(ppm)vol±25×10-6(ppm)vol (absolute error) ±8%(relative error) |
Repeatability |
Repetition error≤+/- 2% |
Stability |
Automatic zero, moment drift less than≤±3% |
Resolution |
HC:1x10-6(ppm)vol CO: 0.01x10-2(%)vol CO2: 0.1x10-2(%)vol O2: 0.01x10-2(%) vol NOx: 1x10-6(ppm)vol Lambda: 0.01 R.P.M:10r.p.m OIL TEMP:0.1℃ |
95% repose time no more than 10 seconds |
|
8min ( Emergency detection can be preheated 3 min) |
|
Output Mode |
Can display, print gas maximum/average/minimum value , test time, date, speed, temperature and COcor value of lambda,can interface with computer networking |
Environment |
Temperature-5 ~ 50 ℃, relative humidity ≤90% |
Power |
AC100-240V 50/60Hz or DC12V ( anthology add power inverter power dissipation of 40VA ) |
Dimensions |
420mm (L) x 340mm (W) x 170mm (H) (with bracket) |
Weight |
About 10kg |