Measuring range: 0.5MPa ~ 1.4MPa
Power supply: 16~32VDC
Output signal: current output, resistance output (equivalent to mechanical type)
Overloaded pressure: 3.3MPa
Atmospheric pressure: 86~108kPa
Environment humidity: 0~98%
Compensation temperature: -40~+120 ℃
Working temperature: -40~+150 ℃
Reaction time: no more than 2ms.
Accuracy class:
Zero point error ±2%FS (full temperature range)
Measuring range error ±2 %FS (full temperature range)
Vibrating influence: Vibration from any direction with a frequency of 10~100Hz and acceleration of 25g would not result in an error exceed the sensor error range.
Installation position influence: :°
Structure: water-proof, dust-proof
Life span: 107 times force circulation
Installation: install it directly onto the flowing tube or on the container.
Power supply influence:
Power supply voltage in the range of 16 ~ 32VDC, error within ±0.2% of measuring range.
Weight: Max. 100g