12.1" Patient Monitor ICU Monitor NIBP RESP SPO2

Model:RPM-9000A
Brand:Risingmed
Origin:Made In China
Category:Electronics & Electricity / Other Electrical & Electronic
Label:Patient Monitor , ICU Monitor
Price: US $950 / pc
Min. Order:1 pc
Inquire Now

Member Information

Detail

Product Description

Features:   
  • Ergonomic design, portable, convenient for use
  • 12.1" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
  • Unique digital SPO2 technology can work accurate during motion and low perfusion
  • Anti AC & high-frequency electrosurgical & defibrillators interference
  • Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
  • Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
  • ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
  • Audible & visual alarm available, adjustable
  • Patient information management function
  • Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
  • Flexible data storage & transfer/software upgrading based on USB
  • Wired/wireless networking with central monitoring system, up to 64 beds in one group
  • Built-in 3 trace thermal recorder for printing real-time and historical data
  • Multi-language i.e. English, Spanish, French, Italian, Turkish, German, Russian etc.
  • Super long life rechargeable dual lead-acid battery (optional) upto 4 hours of working time
  • Suitable for adult, pediatrics and neonate patients
Standard configuration:            
  • ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable lead-acid battery
Optional:            
  • Dual TEMP
  • Dual IBP
  • ETCO2 (side stream) 
  • Thermal recorder
  • Wall mount
  • Trolley
Specification:
 
 
ECG
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate: 
Scope: 15 times/minute to 300 times/minutes
Accuracy:  ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period. 
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.   
Accuracy: Error rate < 20%         
Undetected rate < 20% 
ST section 
Scope:     ±0.8mV
Precision : 
±0.05mV
SpO2
Detection scope:   0%-100%
Accuracy         ±1%     90%-100%               
                 ±2%      70%-89% 
NIBP 
Theory Electric oscillator 
Cuff gassing time   less than 15 seconds
First-time gassing pressure: dynamic state 24kPa
180 mmHg
Manual selection: 9.3kPa
70 mmHg),13.3kPa100 mmHg),16.0kPa120 mmHg
18.6kPa
140 mmHg),20.0kPa150 mmHg),21.3kPa160 mmHg),
Automatic detection period: 1 minute to 240 minutes 
Stop size
1 min1 min -10min, 5min(10 min -30min), 10min(30 m
in -90min) and 30min
90 min -240min
Detection scope: 
Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure               2.7kPa
31.3kPa       20mmHg235mmHg
Detection accuracy 
Static pressure: ±3mmHg
Pulse rate:  ±2%
Resp
Chest impedance method or concentration of carbon dioxide at end of respiration 
Scope of chest impedance method     0 time/minute – 100 minutes/minute 
Precision of chest impedance method  time/minute 
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg
0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute
including baby
Detection precision of respiration rate: ±1 time/minute 
Temp
Single/double path 
Type:    Vascular/surface temperature 
Scope:    20
50
Accuracy:  ±0.2
Invasive blood pressure (optional)
Single/double path 
Type: direct and continuous detection 
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
Pa(100mmHg) above ±2%
Frequency response
DC-12Hz
Input resistance: not less than 500kΩ
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage
5V (DC)
Accuracy of sensor: ±2
Isolation voltage: 4 kV

Product Image

12.1" Patient Monitor ICU Monitor NIBP RESP SPO2 1
Img 1
12.1" Patient Monitor ICU Monitor NIBP RESP SPO2 2
Img 2
12.1" Patient Monitor ICU Monitor NIBP RESP SPO2 3
Img 3

Send Inquiry to this Member

Beijing Risingmed medical company

Suite 506, Longguan Zhiye Building Changping district Beijing

Phone:
86-010-51290013
Fax:
86
Contact:
Anita Liu (Sales )
Mobile:
15101596603

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Other Electrical & Electronic Made In China Products

,  

Other Electrical & Electronic China Suppliers and China Manufacturers