Model: | LPV-20 |
---|---|
Brand: | MEANWELL |
Origin: | Made In China |
Category: | Electronics & Electricity / Power Supply & Distribution / Other Power Supply & Distribution |
Label: | MEAN WELL , LED POWER SUPPLY , CONSTANT VOLTAGE |
Price: |
US $7.9
/ pc
|
Min. Order: | 50 pc |
Last Online:13 Mar, 2012 |
MODEL |
LPV-20-5 |
LPV-20-12 |
LPV-20-15 |
LPV-20-24 |
|
OUTPUT |
DC VOLTAGE |
5V |
12V |
15V |
24 |
CONSTANT CURRENT OPERATION VOLTAGE Note7 |
|
|
|||
CURRENT RANGE |
0 ~ 3A |
0 ~ 1.67A |
0 ~ 1.33A |
0 ~ 0.84A |
|
RATED CURRENT |
3A |
1.67A |
1.33A |
0.84A |
|
RATED POWER |
15W |
20W |
20W |
20.2W |
|
RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
|
VOLTAGE ADJ. RANGE |
|
||||
CURRENT ADJ. RANGE |
|
||||
VOLTAGE TOLERANCE Note.3 |
5.0% |
||||
LINE REGULATION |
1.0% |
||||
LOAD REGULATION |
2.0% |
||||
SETUP, RISE TIME NOTE.6 |
500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load |
||||
HOLD UP TIME (Typ.) |
50ms/230VAC 16ms/115VAC at full load |
||||
INPUT |
VOLTAGE RANGE |
90 ~ 264VAC 127 ~ 370VDC |
|||
FREQUENCY RANGE |
47 ~ 63Hz |
||||
POWER FACTOR |
|
||||
EFFICIENCY (Typ.) |
77% |
81% |
83% |
83% |
|
AC CURRENT (Typ.) |
0.55A/115VAC 0.35A/230VAC |
||||
INRUSH CURRENT (Typ.) |
COLD START 35A/115VAC 70A/230VAC |
||||
LEAKAGE CURRENT |
0.25mA / 240VAC |
||||
PROTECTION |
OVER CURRENT |
110 ~ 150% rated output power |
|||
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||
SHORT CIRCUIT |
|
|
|
|
|
OVER VOLTAGE |
5.75 ~ 6.75V |
13.8 ~ 16V |
17.5 ~ 21V |
28 ~ 32V |
|
Protection type : Shut off o/p voltage, clamping by zener diode |
|||||
OVER TEMPERATURE |
|
||||
|
|||||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +70 (Refer to output load derating curve) |
|||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||
STORAGE TEMP., HUMIDITY |
-40 ~ +80 , 10 ~ 95% RH |
||||
TEMP. COEFFICIENT |
0.03%/ (0 ~ 50 ) |
||||
VIBRATION |
10 ~ 500Hz, 2G 12min./1cycle, period for 60min. each along X, Y, Z axes |
||||
SAFETY &EMC(Note 4) |
SAFETY STANDARDS |
UL879, UL1310 Class 2, CAN/CSA C22.2 No. 223-M91, IP67 approved ; design refer to TUV EN60950-1, EN61347-2-13 |
|||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC |
||||
ISOLATION RESISTANCE |
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH |
||||
EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
||||
HARMONIC CURRENT |
Compliance to EN61000-3-2 Class A,EN61000-3-3 |
||||
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A |
||||
OTHERS |
MTBF |
786.5Khrs min. MIL-HDBK-217F (25 ) |
|||
DIMENSION |
118*35*26mm (L*W*H) |
||||
PACKING |
0.22Kg; 60pcs/14.2Kg/0.62CUFT |
||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. |