Home > Products > Chemicals > Chemical Reagent

No Image

    Gentamicin Residue Rapid Inspection kit

    Model:-
    Brand:Glory science co.,ltd
    Origin:Made In Hong Kong S.A.R
    Category:Chemicals / Chemical Reagent
    Label:Gentamicin kit , Gentamicin , Gentamicin Rapid kit
    Price: US $380 / kit
    Min. Order:50 kit
    Inquire Now Add to Basket

    Member Information

    Detail

    Glory Science Co., Ltd.

    Free MemberZhe Jiang - China
    Live Chat:Last Online:25 Nov, 2016

    Product Description


    Gentamicin Residue Rapid Inspection Device is a rapid, one step test for the qualitative detection of Gentamicin in tissue samples, include meat, shrimp, fish etc.. The whole time of assay is only approx. 10~15min.


     


    2. SUMMARY


     


    Gentamicin(GEN), one kind of  broad-spectrum antibiotic, is effcetive to treat the infectious disease. It has been widely used in different lines of poltry, cattle, agriculture and beekeeping at present. But Gentamicin(CAP) can do harm to human body, it will inhibit the hematopoiesis function of marrow, thereby induce not only the Aplastic Anemia and agranulocytopenia, but also induce disease of human beings’ gastrointesinal tract and affect the nervous system.


     


    Radioimmunologic or gas chromatographic method is applied for Gentamicin residue. Howerver, enzyme immunoassays shows considerable advantages over conventional methods. Radioactive materials are no longer required, and the time is  less than the gas chromatographic method.


    TheGentamicin Residue Rapid Inspection Device is rapid test for qualitivie detection of Gentamicin in specimens at the sensitivity of 50μg/kg (ppb). The major advantages of the one step test device are that the result can be observed by visual and no additional material is needed.


     


    3. PRINCIPLE


     


    The basis of the test is the antigen-antibody reaction. The one step test device is a competitive immunoassay in which the detector reagent consists of colloidal gold particles coated with affinity purified anti-Gentamicin antibodies. The capture reagent in the assay is a Gentamicin-protein conjugate, which is immobilised on the membrane of the test device. In the test procedure, specimens migrate over the membrane. The more analyte present in the sample, the more effectively it will compete with the Gentamicin immobilised on the membrane for binding to the limited amount of antibodies of the detector reagent. Gentamicin, if present in the specimen above 50μg/kg, will thus prevent the binding of the detector reagent to the Gentamicin immobilised on the membrane, resulting in a positive result.


     


    Send Inquiry to this Member

    Glory Science Co., Ltd.

    1/F, 160 Hehuayuan, Lianhua Street, Hangzhou, Zhejiang, China

    Phone:
    86-571-86752285
    Fax:
    Contact:
    Victor (trade assistant)
    Mobile:
    15356140698

    Related Products of this Company

    This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
    To report fraudulent or illegal content, please click here.

    China Suppliers Quick Searching:

    Chemical Reagent Made In China Products

    ,  

    Chemical Reagent China Suppliers and China Manufacturers