Model |
HF6K |
HF10K |
||
Rated Power |
VA/W |
6kVA/4.2kW |
10kVA/7kW |
|
Input |
Nominal Voltage |
220VAC |
||
Voltage Range |
176 ~ 276VAC |
|||
Frequency Range |
46 ~ 54Hz |
|||
Power Factor |
0.98 |
|||
Connection |
Hardwired |
|||
Output |
Voltage |
220VAC/230VAC/240VAC ± 1% |
||
Frequency |
Sync with input frequency. If input frequency is out the range of 46Hz – 54Hz(57Hz – 63Hz), the output frequency is 50Hz(60Hz) × (1±0.2%)Hz. 50Hz or 60Hz×(1±0.2%)Hz 〔 battery mode 〕 |
|||
Waveform |
Sine Wave |
|||
Power factor |
0.7 |
|||
Voltage Distortion |
2% under linear load |
|||
Overload Capability |
105% ~ 130% for 10 min., ³ 130% for 1 min. |
|||
Current Crest Ratio |
3:1 max. |
|||
Connection |
Hardwired |
|||
Battery |
Type |
Sealed, Maintenance free, Lead-Acid |
||
Quantity |
20 pieces |
|||
Back-up time (full load) |
7 min |
5 min |
||
Recharge time |
8 hrs to 90% of capacity after full load discharge |
|||
Transfer time |
0 ms |
|||
LED OR LCD |
Status |
Load level/Battery level, Battery , Utility power, Inverter, Bypass, Overload, Fault |
||
Audible alarm |
Bypass |
Alarm beeps every two minutes |
||
Battery discharge |
Alarm beeps every four seconds, every second if battery low |
|||
Overload |
Alarm beeps two for every second |
|||
Fault |
Alarm beeps continuously |
|||
Acoustic noise |
At 1 meter distance |
£ 55 dB |
||
Communications |
DB-9 Port |
RS232 serial interface |
||
Intelligent Slot |
Options: WebPower, AS400 or WinPower CMC |
|||
Environmental |
Operating temperature |
0 ~ 40 ° C |
||
Operating humidity |
20% ~ 90% non-condensing |
|||
Weight |
Net (kg) |
84 |
180 |
|
Dimensions |
W x D x H (mm) |
260 * 555 * 710 |
340 * 640 * 980 |
Model |
HF6KS |
HF10KS |
||
Rated Power |
Volt-Amps/Watts (VA/W) |
6kVA/4.2kW |
10kVA/7kW |
|
Input |
Nominal Voltage |
220VAC |
||
Voltage Range |
176 ~ 276VAC |
|||
Frequency Range |
46 ~ 54Hz |
|||
Power Factor |
0.98 |
|||
Connection |
Hardwired |
|||
Output |
Voltage |
220VAC/230VAC/240VAC ± 1% |
||
Frequency |
Sync with input frequency. If input frequency is out the range of 46Hz – 54Hz(57Hz – 63Hz), the output frequency is 50Hz(60Hz) × (1±0.2%)Hz. 50Hz or 60Hz×(1±0.2%)Hz 〔 battery mode 〕 |
|||
Waveform |
Sine Wave |
|||
Power factor |
0.7 |
|||
Voltage Distortion |
2% under linear load |
|||
Overload Capability |
105% ~ 130% for 10 min., ³ 130% for 1 min. |
|||
Current Crest Ratio |
3:1 max. |
|||
Connection |
Hardwired |
|||
Battery |
Type |
Sealed, Maintenance free, Lead-Acid |
||
Nominal DC Voltage |
240VDC |
|||
Back-up time |
Depends on the capacity of the external battery bank |
|||
Connection |
External Battery Socket |
|||
Transfer time |
0 ms |
|||
LED OR LCD |
Status |
Load level/Battery level, Battery , Utility power, Inverter, Bypass, Overload, Fault |
||
Audible alarm |
Bypass |
Alarm beeps every two minutes |
||
Battery discharge |
Alarm beeps every four seconds, every second if battery low |
|||
Overload |
Alarm beeps two for every second |
|||
Fault |
Alarm beeps continuously |
|||
Acoustic noise |
At 1 meter distance |
£ 55 dB |
||
Communications |
DB-9 Port |
RS232 serial interface |
||
Intelligent Slot |
Options: WebPower, AS400 or WinPower CMC |
|||
Parallel Port |
up to three units in parallel for power redundancy and load sharing |
|||
Environmental |
Operating temperature |
0 ~ 40 ° C |
||
Operating humidity |
20% ~ 90% non-condensing |
|||
Weight |
Net (kg) |
45 |
92 |
|
Dimensions |
W x D x H (mm) |
260 * 555 * 710 |
340 * 640 * 980 |