Home > Products > Consumer Electronics & Lighting > Water Heater

air to water heat pumpinverter heat pumpR32 heat pumphot water heat pumpR32 EVI inverter heat pump RS10V/L 5R32 EVI inverter heat pump RS10V/L 6R32 EVI inverter heat pump RS10V/L 7R32 EVI inverter heat pump RS10V/L 8R32 EVI inverter heat pump RS10V/L 9R32 EVI inverter heat pump RS10V/L 10R32 EVI inverter heat pump RS10V/L 11R32 EVI inverter heat pump RS10V/L 12R32 EVI inverter heat pump RS10V/L 13R32 EVI inverter heat pump RS10V/L 14R32 EVI inverter heat pump RS10V/L 15
  • air to water heat pump
  • inverter heat pump
  • R32 heat pump
  • hot water heat pump
  • R32 EVI inverter heat pump RS10V/L 5
  • R32 EVI inverter heat pump RS10V/L 6
  • R32 EVI inverter heat pump RS10V/L 7
  • R32 EVI inverter heat pump RS10V/L 8
  • R32 EVI inverter heat pump RS10V/L 9
  • R32 EVI inverter heat pump RS10V/L 10
  • R32 EVI inverter heat pump RS10V/L 11
  • R32 EVI inverter heat pump RS10V/L 12
  • R32 EVI inverter heat pump RS10V/L 13
  • R32 EVI inverter heat pump RS10V/L 14
  • R32 EVI inverter heat pump RS10V/L 15

R32 EVI inverter heat pump RS10V/L

Model:RS10V/L
Brand:Hiseer
Origin:Made In China
Category:Consumer Electronics & Lighting / Water Heater
Label:R32 heat pump , inverter heat pump , hot water heat pump
Price: -
Min. Order:5 pc
Inquire Now Add to Basket

Member Information

Detail

Guangzhou Hiseer Air conditioning Co.,Ltd

Biz MemberGuang Dong - China
Live Chat:
Last Online:28 Oct, 2022

Product Description

R32 making up 50% of the  R410A refrigerant , R32 has a GWP of 675 (one third that of R410A), is highly energy efficient and is easy to recycle. Plus, the volumetric capacity of R32 is around 20% higher than that of R410A, which means system refrigerant volumes are lower. R32 is a single component refrigerant, meaning it is easier to reuse and to recycle. It is also relatively inexpensive to produce, is easier to handle because it doesn’t separate and utilises familiar technology, keeping costs similar.

R32: The Benefits:

  • Low GWP of 675

  • High efficiency refrigerant

  • F–Gas phasedown compliant

  • Less refrigerant volume requirement compared to R410A

  • Affordable & readily available

  • A single component refrigerant

  • Easy to handle, reuse and recycle

  • Used in our newest, state–of–the–art products

 

With a Hiseer R32 EVI inverter heat pump. you still get the performance and efficiencies needed for the buildings, using refrigerants and equipment that delivers a much lower GWP overall.

 

Model Number RS10V/L-QPNHV
Heating performance Min. Nominal  Max.
Heat output/Power consumption/COP at A7/W35℃  kW 2.60/0.54/4.74 9.55/2.20/4.34 10.20/2.46/4.15
Heat output/Power consumption/COP at A2/W35℃  kW 4.10/0.86/4.51 8.80/2.28/3.86 9.40/2.48/3.79
Heat output/Power consumption/COP at A-7/W35℃  kW 3.60/1.29/2.79 7.18/2.24/3.21 7.60/2.42/3.14
Heat output/Power consumption/COP at A-10/W35℃ kW 3.20/1.28/2.50 6.78/2.25/3.01 7.20/2.43/2.96
Heat output/Power consumption/COP at A-15/W35℃ kW 2.16/1.28/1.67 6.13/2.38/2.58 7.20/2.94/2.45
Heat output/Power consumption/COP at A7/W45℃   kW 3.75/1.00/3.75 11.23/3.07/3.66 11.98/3.32/3.61
Heat output/Power consumption/COP at A2/W45℃  kW 4.19/1.47/2.85 10.15/3.12/3.25 10.82/3.51/3.08
Heat output/Power consumption/COP at A-7/W45℃   kW 3.24/1.81/1.79 8.21/3.19/2.57 8.75/3.75/2.33
Heat output/Power consumption/COP at A-10/W45℃ kW 3.04/1.81/1.68 7.56/3.21/2.36 8.06/3.63/2.22
Heat output/Power consumption/COP at A-15/W45℃ kW 2.65/1.90/1.39 6.49/3.24/2.00 6.92/3.52/1.97
Heat output/Power consumption/COP at A7/W55℃   kW 3.19/1.05/3.04 10.35/3.48/2.98 11.04/3.92/2.81
Cool output/Power consumption/EER at A35/W7℃ kW 1.72/0.57/3.00 6.00/2.45/2.45 6.43/2.75/2.34
Nominal running current at A7/W35 A 9.8
Auxiliary electric heater  KW   3  
Max operating current  (aux. heater running) A 16 (29)
Max. power consumption (aux. heater running) KW   3.7 ( 6.7)  
Power Supply   220-240V/1phase/50Hz
Compressor   Panasonic EVI twin rotary
Condenser   Brazed plate heat exchanger
Nominal flow heating medium m3/h 1.64
Internal pressure drop at nominal flow kPa 19
Nominal air flow m3/h 3000
Nominal fan output  W 110
Max outlet heating medium temperature 55
Refrigerant R32 filling weight kg 1.8
Dimensions (HxWxD) mm 1005 x 1060 x 420 
Pipe connector   G1' external thread
Net Weight kg 102
Operating ambient temp. range Heating -25~35
Cooling 10~43
Sound power level LWA dB(A) 61
The above data is tested by EN14511. A7/W35℃ means air temp. 7℃,outlet water temp. 35℃  
The Sound power level is tested by EN12102        

 

 

 

Product Image

air to water heat pump
Img 1
inverter heat pump
Img 2
R32 heat pump
Img 3
hot water heat pump
Img 4
R32 EVI inverter heat pump RS10V/L 5
Img 5
R32 EVI inverter heat pump RS10V/L 6
Img 6
R32 EVI inverter heat pump RS10V/L 7
Img 7
R32 EVI inverter heat pump RS10V/L 8
Img 8
R32 EVI inverter heat pump RS10V/L 9
Img 9
R32 EVI inverter heat pump RS10V/L 10
Img 10
R32 EVI inverter heat pump RS10V/L 11
Img 11
R32 EVI inverter heat pump RS10V/L 12
Img 12
R32 EVI inverter heat pump RS10V/L 13
Img 13
R32 EVI inverter heat pump RS10V/L 14
Img 14
R32 EVI inverter heat pump RS10V/L 15
Img 15

Send Inquiry to this Member

Guangzhou Hiseer Air conditioning Co.,Ltd

xicheng industry zone,renhe town,guangzhou china

Phone:
86-20-61171400
Fax:
86-20-61168929
Contact:
Jerry He (sales)
Mobile:
13798056642

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Water Heater Made In China Products

,  

Water Heater China Suppliers and China Manufacturers