Home > Products > Chemicals > Other Chemicals

Accu-Tell® Multi-Drug Saliva Rapid Test Cassette 1Accu-Tell® Multi-Drug Saliva Rapid Test Cassette 2Accu-Tell® Multi-Drug Saliva Rapid Test Cassette 3Accu-Tell® Multi-Drug Saliva Rapid Test Cassette 4
  • Accu-Tell® Multi-Drug Saliva Rapid Test Cassette 1
  • Accu-Tell® Multi-Drug Saliva Rapid Test Cassette 2
  • Accu-Tell® Multi-Drug Saliva Rapid Test Cassette 3
  • Accu-Tell® Multi-Drug Saliva Rapid Test Cassette 4

Accu-Tell® Multi-Drug Saliva Rapid Test Cassette

Model:-
Brand:-
Origin:Made In China
Category:Chemicals / Other Chemicals
Label:Testing Instrument , Rapid Test , Drug of abuse test
Price: -
Min. Order:500 pc
Inquire Now Add to Basket

Member Information

Detail

Accubiotech Co.,Ltd

Free MemberBeijing - China
Live Chat:Last Online:08 May, 2020

Product Description

Accu-Tell® Multi-Drug Saliva Rapid Test Cassette

Multi-Drug Rapid Test Urine Cup

Accu-Tell® Multi-Drug Saliva Rapid Test Cassette for AMP/MET/COC/OPI/THC/PCP/MTD/MDMA/OXY/COT/BZO/KET/6-MAM is a lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in saliva.

CATALOG

Product Name

Specimen

Catalog No.

Quantity per box

Multi-2 Drug Saliva Cassette

Saliva

ABT-DOA-B142

15T

Multi-3 Drug Saliva Cassette

Saliva

ABT-DOA-B143

15T

Multi-4 Drug Saliva Cassette

Saliva

ABT-DOA-B144

15T

Multi-5 Drug Saliva Cassette

Saliva

ABT-DOA-B145

15T

Multi-6 Drug Saliva Cassette

Saliva

ABT-DOA-B146

15T

Multi-7 Drug Saliva Cassette

Saliva

ABT-DOA-B147

15T

Multi-8 Drug Saliva Cassette

Saliva

ABT-DOA-B148

15T

Multi-9 Drug Saliva Cassette

Saliva

ABT-DOA-B149

15T

Multi-10 Drug Saliva Cassette

Saliva

ABT-DOA-B150

15T

 

INTENDED USE 

ACCU-TELL® Multi-Drug Rapid Test Panel for AMP/MET/COC/OPI/THC/PCP/MTD/MDMA/OXY/COT/BZO/KET/6-MAM is a lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in saliva at the following cut-off concentrations:

Test

Calibrator

Cut-off (ng/mL)

Amphetamine (AMP)

d-Amphetamine

50

Methamphetamine (MET)

d-Methamphetamine

50

Marijuana (THC)

THC-COOH

12

Marijuana (THC)

THC-COOH

50

Phencyclidine (PCP)

Phencyclidine

10

Cocaine (COC)

Benzoylecgonine

20

Opiates (OPI)

Morphine

40

Methadone (MTD)

Methadone

30

Oxycodone (OXY)

Oxycodone

20

Cotinine(COT)

Cotinine

30

Methylenedioxymethamphetamine (MDMA)

d,l-Methylenedioxymethamphetamine

50

Benzodiazepines(BZO)

Oxazepam

20

Ketamine(KET)

Ketamine

50

6-Monoacetylmorphine(6-MAM)

6-Monoacetylmorphine

10

 

This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) and gas chromatography/tandem mass spectrometry (GC/MS/MS) are the preferred confirmatory methods. Professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated.

 

TEST PROCEDURE of Drug Metabolites Rapid Test 

Allow the test cassette, specimen, and/or controls to reach room temperature (15-30°C) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.

1. Bring the pouch to room temperature before opening it. Remove the test from the sealed pouch and use it within one hour.

Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated.

2. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid.  Discard the collector.  Snap the cap shut on the collection chamber.

3. Place the test cassette on a clean and level surface.  Unscrew cap cover from the collection chamber.  Invert the collection chamber and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette and start the timer.  Avoid trapping air bubbles in the specimen well. Place screw cap on the collection chamber. See illustration above.

 We are Drug Of Abuse Rapid Tests Supplier.

 

LIMITATIONS

1. ACCU-TELL® Multi-Drug Saliva Rapid Test Cassette provides only a qualitative, preliminary analytical result. A secondary analytical method must be used to obtain a confirmed result. Gas chromatography/mass spectrometry (GC/MS) or gas chromatography/tandem mass spectrometry (GC/MS/MS) is preferred confirmatory methods.

2. A positive test result does not indicate the concentration of drug in the specimen or the route of administration.

3. A negative result may not necessarily indicate a drug-free specimen. Drug may be present in the specimen below the cutoff level of the assay.

Note: The above information is for reference use only. Please refer to the product insert provided with the products before use.


Payment Terms:TT, LC

Product Image

Accu-Tell® Multi-Drug Saliva Rapid Test Cassette 1
Img 1
Accu-Tell® Multi-Drug Saliva Rapid Test Cassette 2
Img 2
Accu-Tell® Multi-Drug Saliva Rapid Test Cassette 3
Img 3
Accu-Tell® Multi-Drug Saliva Rapid Test Cassette 4
Img 4

Send Inquiry to this Member

Accubiotech Co.,Ltd

Building 10, No. 28 Yuhua Road

Phone:
86-010-80484980
Fax:
Contact:
Andy Wang (manager)
Mobile:
18618286059

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Other Chemicals Made In China Products

,  

Other Chemicals China Suppliers and China Manufacturers