MEWOI9000G Flexible Coil Leakage Current Monitoring Recorder
Product Description
TECHNICAL SPECIFICATION
Functions |
Field-line testing, monitoring, recording AC leakage current and Large current |
Power source |
DC6V, alkaline battery LR06 1.5V×4 |
Testing Method |
By integrating the output voltage signal , you can restore the real input current |
Inner diameter |
(φ300mm(Optional,Can be customized) |
Range |
0.00A-20.000KA |
Resolution |
10mA |
Accuracy |
±2%±3dgt(cable in the center of the coil,23℃±2℃) |
Coil Length |
1000mm((Can be customized)) |
Current Frequency |
50Hz~60Hz(The measured current frequency,Automatic Identification) |
LCD Display |
LCD:128dots×64dots |
LCD Size |
44mm×27mm |
Host Dimension |
W*L*H75mm×170mm×30mm
|
Diameter |
φ7.5mm(Suitable for narrow cable-intensive sites) |
Weight |
Host(240g),Flexible Coil(150g) |
Electric field interference |
no magnetic saturation, high linearity, strong anti-interference ability |
Position error |
cable in the center of the coil,don't put the cable at the split area,error doubles or more at the split area |
Sampling Rate |
2 samples/s |
Data storage |
4200 sets (data loss does not occur after power failure or replacing the battery) |
Time Setting |
Recording internal adjustable from 1 to 60 min, If set to 0 min, the auto-store function is turned off |
Recording Time |
Continuously operate for about 100hours at the power-saving mode |
Line Voltage |
Line with a voltage up to AC600V |
Overflow Display |
The “OL” symbol is displayed when a measured value is beyond the measurement range |
Battery. Voltage |
A Low-Battery symbol is displayed and the user should replace the battery with a new one when the battery voltage drops to 4.6V to 4.8V. In this case, the measured values are still accurate. |
Rated Power |
about 5mA at the power-saving mode, maximum current consumption: 20mA |
Lead Length |
2m |
Temperature and Humidity |
Working: -10℃~40℃;below 80%rh |
Storage: -10℃~60℃;below 70%rh |
Insulation Resistance |
Higher than 100MΩ, 1000V |
Safety Codes |
IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard) |
Accessories |
Host: 1 PCS, Flexible Coil: 1 PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS,Batteries:LR06:4pcs |
Payment Terms: | T/T ,western-union,paypal |
| |
Product Image
Send Inquiry to this Member
Related Products of this Company
This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please
click here.