Model: | JR9100-003G-4-9 |
---|---|
Brand: | - |
Origin: | Made In China |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | 380V Variable Freque , Variable Frequency D , Frequency Inverter |
Price: |
-
|
Min. Order: | - |
Live Chat: | Last Online:30 May, 2018 |
Chapter 2 Product Information
2.1 Naming and nameplate identification
2.1.1 naming rule
JAC580N- 004G - 4 - 5020A
JAC580N frequency
|
Enclosure No. |
indentification | Voltage level |
4 | three-phase 380V |
S2 | Single-phase 220V |
2 | Three-phase 220V |
Indentification | Adaptive motor type |
G | General type |
Indentification | 0.4 | 0.75 | ... | 400 |
Adaptive motor(KW) | 0.4 | 0.75 | ... | 400 |
2.2Introduction of various parts of the converter
JAC580N series converter is the plastic structure type.the external diagram is shown below.
2.3 Basic technical specification
Table 2-1 Technical specification of 580N series frequency converter
Item | Specification | ||
Standard functions | Maximum frequency | Vector control: 0~500Hz; V/F control: 0~500Hz | |
Carrier frequency | 0.8kHz~12kHz
The carrier frequency is automatically adjusted based on the load features. |
||
Input frequency
resolution |
Digital setting: 0.01Hz
Analog setting: maximum frequency x 0.025% |
||
Control mode | • Open-loop vector control (SVC)
• Closed-loop vector control (FVC) • Voltage/Frequency (V/F) control |
||
Starting torque | • G type: 0.5 Hz/150% (SVC); 0 Hz/180% (FVC)
• P type: 0.5 Hz/100% |
||
Basic functions |
Speed range | 1:100 (SVC) | 1:1000 (FVC) |
Constant-speed accuracy | ± 0.5% (SVC) | ± 0.02% (FVC) | |
Overload capacity | • G type:60s for 150% of the rated current
• P type: 60s for 120% of the rated current. |
||
Torque boost | • Fixed boost
• Customized boost 0.1%-30.0% |
||
V/F curve | • Straight-line V/F curve
• Multi-point V/F curve •N-power V/F curve (1.2-power, 1.4-power, 1.6-power, ,1.8-power, square) |
||
V/F separation | Two types: complete separation; half separation | ||
Acceleration /deceleration curve | • Straight-line ramp
• S-curve ramp Four groups of acceleration/deceleration time with the range of 0.0-6500.0s |
||
DC braking | DC braking frequency: 0.00Hz~maximum frequency
Braking time: 0.0s~36.0s Braking action current value: 0.0%-100.0% |
||
JOG control | JOG frequency range: 0.00-50.00 Hz
JOG acceleration/deceleration time: 0.0-6500.0s |
||
Operation | Command source | Operation panel, control terminal and serial communication port are given
Switch in various methods |
|
Frequency source | Various frequency sources: digital reference, analog voltage reference, analog current reference, pulse reference and serial port reference. The switching can be conducted in various methods | ||
Auxiliary frequency source | 10 kinds of auxiliary frequency source. The auxiliary frequency jog and frequency synthesis can be achieved flexibly | ||
Input terminal | Standards:
7 digital input terminals, among which one support maximum high-speed pulse input of 100kHz 2 analog input terminals, among which one only supports voltage input of 0 ~10V and the other supports voltage input of 0 ~10V or current input of 4 ~20mA Expansion capability: 3 digital input terminals 1 analog input terminal, which supports voltage input of -10V ~10V and supports PT100/PT1000 |
||
Output terminal | Standards:
1 high-speed pulse output terminal (The open collector type is optional), supporting 0~100kHz square signal output 1 digital output terminal 1 relay output terminal 1 analog output terminal, supporting current output of 0~20mA or voltage output of 0~10V Expansion capability: 1 digital output terminal 1 relay output terminal 1 analog output terminal, supporting current output of 0~20mA or voltage output of 0~10V |
||
Display and keyboard operation | LED display | Display the parameter | |
Key lock and function selection | Realize partial or all key lock and define the action range of some keys to prevent misoperation | ||
Protection function | Short circuit test of electrified motor, input/output default phase protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection, etc. |