12HP Industrial Water Cooled Type Water Chillers
Product Description
12HP Industrial Water Cooled Type Water Chillers
Description of the Standard Water Cooled Chillers,
The water chiller is to provide a cooling process in plastic molding, to improve quality of molded products and shorten period of injection molding cycles.
1. Famous brand new compressors, high efficient shell condensers and evaporators -- excellent cooling, quiet with low electric consumption.
2. P.I.D. Microprocessor control-easy to operate accurately maintains temperature range from 3 to 50.
Working Principle of the Water Chillers,
Specification of the Standard Water Cooled Chillers,
Model
Unit
RS-L12W
RS-L15W
RS-L20W
RS-L25W
RS-L30W
RS-L40W
RS-L50W
RS-LF12A
RS-LF15A
RS-LF20A
RS-LF25A
RS-LF30A
RS-LF40A
RS-LF50A
Capacity
KW
34.3
45
61
69
92
122
136
Kcal/h
29498
38700
52460
59340
79120
104920
117476
Compressor
Input power
KW
10
4.5x3
9x2
10x2
9x3
9x4
9.4x4
Related power
HP
6x2
5x3
10x2
12.5x2
10x3
10x4
12.5x4
Power
3HP-380V/50HZ(200V/220V/415V 50HZ/60HZ)
Evaporator
Type
Water tank with coil(Shell and Tube)
Pipe diameter
inch
2"
2"
2.5"
2.5"
3"
3"
3"
Refrigerant
Type
R22
Quantity
kg
5
7.5
11
11
12
18
18
Water Condenser
Type
Pipe diameter
inch
2"
2"
2.5"
2.5"
3"
3"
3"
Cooling Water
Flow
m3/h
5.03
7.1
8.84
10.06
13.6
17.75
21.9
Air Condenser
Type
Finned copper tube+ Low noise outer rotor fan
Fan power
W
550x2
750x2
550x3
750x3
800x3
800x3
800x4
Water tank
capacity
Liter
110
200
350
350
420
420
420
Pump
Power
KW
0.75
1.5
1.5
2.2
2.2
4
4
HP
1
2
2
3
3
5
5
Distance
m
13
15
15
16
16
16
16
Flow Rate
L/min
200
360
360
650
650
700
700
Safety
Protection
High and low Pressure Protection,Over Load Protection,Over Temperature Protection,Phase Sequence Protection etc.
Dimensions (L*W*H)
Water Cooled
mm
1270*650*
1413
1270*650
*1413
1880*880
*1650
1880*880*
1650
1880*880*
1650
2150*1080*
1950
2150*1080*
1950
Air Cooled
mm
1550*830* 1543
1850*1000* 1640
2150*1000* 1820
2400*1150* 1740
2600*1150* 1940
2150*2000* 1820
2400*2250 *1840
Note: Voltage: 3,380V,60Hz;
1.Cooling Capacity is calculated based on: inlet/outlet chilled fluid temperature:12/7,inlet/outlet cooling water temperature:30/35.
2.Working condition: Chilled fluid temperature: from 5 to 35. Inlet/outlet chilled fluid Temperature difference: from 3 to 8
Cooling water temperature: from 18 to 37, Inlet/outlet cooling water Temperature difference: from 3.5 to 10.
We reserve the right to change specifications without prior notice.
OEM Service of the Water Chiller,
http://www.rs-plastics-machinery.com
Product Image
Img 1
Send Inquiry to this Member
Related Products of this Company
This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please
click here.