Product Description
MODEL |
SKY |
300W |
500W |
10kW |
50kW |
100kW |
Input |
Power tracking window range [Vdc] |
150 to 600 |
200 to 600 |
350 to 700 |
Max open circuit voltage [Vdc] |
800 |
800 |
800 |
Min DC voltage for feed-in [Vdc] |
1500 |
200 |
350 |
Max DC current [Adc] |
10 |
20 |
34 |
120 |
217 |
Output |
Nominal power rating [kW] |
3.0 |
5.0 |
10 |
50 |
100 |
Max AC line current [Aac] |
15 |
25 |
16.7 |
83.6 |
167 |
AC operating voltage [Vac] |
1-Phase 220VAC |
1-Phase 220VAC |
Frequency [Hz] |
50 / 60 Hz |
Conversion efficiency [%] |
98 |
98 |
94 |
96 |
97 |
Additional |
DC/AC isolation |
No |
Yes |
Cooling |
Natural air |
Forced air cooled |
DC reverse polarity protection |
Yes |
Ground fault protection |
|
Integrated ground fault detector/interrupter (GFDI) |
Grounding |
|
Negative ground (optional positive ground configuration) |
Visual displays |
Mono graphical LCD with 4 button |
Included accessory interfaces |
RS485 / Ethernet(Optional) |
Ambient temperature range |
0℃ - + 50℃ |
Thermal protection |
Yes |
Noise emissions [dB] |
<45 |
<55 |
<60 |
<65 |
Relative humidity range [%] |
0-90% (non condensing) |
Max. altitude |
1000m without de-rating |
Night consumption [W] |
<5 |
<15 |
<30 |
Protective functions (Input) |
Over voltage, Over current, Over heat |
Protective functions (Output) |
Over/Under voltage, Over/Under frequency, Anti-Islanding |
Warranty standard |
3years (Extensions available) |
Hardware |
Enclosure environmental rating |
IP65 / NEMA4 |
IP22 / NEMA3R |
IP22 / NEMA3R |
Dimensions (H, W, D) [mm] |
450 X 350 X 160 |
1475 X 555 X 805 |
1800 X1 200 X 905 |
Weight [kg] |
25 |
200 |
1100 |