Home > Products > Electronics & Electricity > Optical Fiber, Cable & Wire > Electric Wire & Cable

Nuclear power cable-Cable for Nuclear Power Station 1Nuclear power cable-Cable for Nuclear Power Station 2Nuclear power cable-Cable for Nuclear Power Station 3Nuclear power cable-Cable for Nuclear Power Station 4Nuclear power cable-Cable for Nuclear Power Station 5
  • Nuclear power cable-Cable for Nuclear Power Station 1
  • Nuclear power cable-Cable for Nuclear Power Station 2
  • Nuclear power cable-Cable for Nuclear Power Station 3
  • Nuclear power cable-Cable for Nuclear Power Station 4
  • Nuclear power cable-Cable for Nuclear Power Station 5

Nuclear power cable-Cable for Nuclear Power Station

Model:-
Brand:BAOSHIDA
Origin:Made In China
Category:Electronics & Electricity / Optical Fiber, Cable & Wire / Electric Wire & Cable
Label:Nuclear power cable , BAOSHIDA , manufacture
Price: US $80 / meter
Min. Order:1 meter
Inquire Now Add to Basket

Member Information

Detail

ShanDong BaoShiDa Cable Co.,Ltd

Free MemberShan Dong - China
Live Chat:Last Online:05 Jan, 2017

Product Description

Application 
The product is authorized as per the standard of RCC-E and IEE383 to use for exterior cable in the nuclear power station and other locales where there is high requirements for electric physics flame resistance of cables.

Type and Name


Type

Name

HEJE-K3

Cross-linked polyolefin insulated PO sheathed LSOH flame-retardant power cable for nuclear power stations

HKEJE-K3

Cross-linked polyolefin insulated PO sheathed LSOH flame-retardant control cable for nuclear power stations

HKEJEP-K3

Cross-linked polyolefin insulated PO sheathed LSOH copper braided shielded flame-retardant control cable for nuclear power stations

HKEJEP2-K3

Cross-linked polyolefin insulated PO sheathed LSOH copper strip shielded flame-retardant control cable for nuclear power stations

HKEJEP3-K3

Cross-linked polyolefin insulated PO sheathed LSOH ELE shielded flame-retardant control cable for nuclear power stations

HKEJEP3P-K3

Cross-linked polyolefin insulated PO sheathed LSOH ELE and copper braided shielded flame-retardant control cable for nuclear power stations

HDJEJEP-K3

Cross-linked polyolefin insulated PO sheathed LSOH copper braided shielded flame-retardant measuring cable for nuclear power stations

HDJEJEP2-K3

Cross-linked polyolefin insulated PO sheathed LSOH copper strip shielded flame-retardant measuring cable for nuclear power stations

HDJEJEP3-K3

Cross-linked polyolefin insulated PO sheathed LSOH ELE shielded flame-retardant measuring cable for nuclear power stations

HDJEJEP3P-K3

Cross-linked polyolefin insulated PO sheathed LSOH ELE and copper braided shielded flame-retardant measuring cable for nuclear power stations

HDJEJPE-K3

Cross-linked polyolefin insulated PO sheathed LSOH copper braided pair twist shielded flame-retardant measuring cable for nuclear power stations

HDJEJPEP-K3

Cross-linked polyolefin insulated PO sheathed LSOH copper braided pair twist and collectively shielded flame-retardant measuring cable for nuclear power stations

HDJEJP2EP2-K3

Cross-linked polyolefin insulated PO sheathed LSOH copper strip pair twist shielded flame-retardant measuring cable for nuclear power stations

HDJEJP3E-K3

Cross-linked polyolefin insulated PO sheathed LSOH ELE pair twist shielded flame-retardant measuring cable for nuclear power stations

HDJEJP3EP3-K3

Cross-linked polyolefin insulated PO sheathed LSOH ELE pair twist and collectively shielded flame-retardant measuring cable for nuclear power stations

Operating Properties 
1、Max. permissible continuous operating temperature of conductor: Not exceeding 90℃.
2、Max. temperature of conductor will not exceed 250℃ when short-cut(in 5 seconds).
3、The temperature when laying the cable should not below 0℃.
4、Insulated with 
5、The density for braided copper screen should be no smaller than 80%.
6、The thermal life for cable should confirm to the requirement that the cable life should be no less than 40 years.
7、Finished cables should pass the test of bundling burning test of Class B specified in GB/T18380.3-2001.
8、Smoke density of finished cables’ burning test should confirm to the requirements of GB/T17651.
9、Release air test for finished cables’ insulation and sheath should confirm to the requirements of GB/T17650.2.

Range of Production


Type

Number of cores

Nominal cross sectional area mm2

HEJE-K3

2~5

1.5~300

HKEJE-K3

 

 

2~37

 

 

0.5~2.5

HKEJEP-K3

HKEJEP2-K3

HKEJEP3-K3

HKEJEP3P-K3

HDJEJE-K3

HDJEJEP-K3

 

 

2cores group:2~15 pairs 
3cores group:2~14 pairs

 

 

0.75、1.0、1.5

HDJEJEP2-K3

HDJEJEP3-K3

HDJEJEP3P-K3

HDJEJPEP-K3

HDJEJP2EP2-K3

HDJEJP3EP3-K3

Max. DC Resistance of conductor at 20℃:


Nom. cross-sectional
of conductor

DC.
resistanceΩ/km

Nom. cross-sectional
of conductor

DC.
resistanceΩ/km

Nom. cross-sectional
of conductor

DC.
resistanceΩ/km

mm²

 copper

 mm²

 copper

 mm²

 copper

0.75

24.5

16

1.15

150

0.124

1

18.1

25

0.727

185

0.0991

1.5

12.1

35

0.524

240

0.0754

2.5

7.41

50

0.387

300

0.0601

4

4.61

70

0.268

400

0.047

6

3.08

95

0.193

500

0.0366

10

1.83

120

0.153

--

--

Current carrying capacity of cable 
Cross-linked polyolefin insulated sheathed LSOH flame-retardant power cable for Nuclear Power Stations


Nom. cross- 
sectional area mm²

 

2 cores

 

3 cores

 

4 cores

 

5 cores

1.5

20

20

27

28

2.5

26

27

35

36

4

34

35

45

46

6

43

44

57

58

10

75

65

70

64

16

100

85

90

84

25

140

115

130

115

35

175

145

165

141

50

210

175

200

172

70

270

220

258

218

95

340

270

320

269

120

400

315

380

313

150

460

360

440

359

185

530

420

505

405

240

625

500

603

451

300

--

580

700

497

400

--

640

795

543

500

--

760

880

--

Operating conditions when laying the cable 
1、Max. operating temperature of conductor: XLPE insulated: 90℃. 
2、Surrounding temperature:40℃.

Correction factors at different ambient air temperatures


ambient air temperature

20

25

30

35

Rating factor

1.18

1.14

1.1

1.05

ambient air temperature

40

45

50

Rating factor

1

0.95

0.89

Product Name: Cable for Nuclear Power Station

 


Product Image

Nuclear power cable-Cable for Nuclear Power Station 1
Img 1
Nuclear power cable-Cable for Nuclear Power Station 2
Img 2
Nuclear power cable-Cable for Nuclear Power Station 3
Img 3
Nuclear power cable-Cable for Nuclear Power Station 4
Img 4
Nuclear power cable-Cable for Nuclear Power Station 5
Img 5

Send Inquiry to this Member

ShanDong BaoShiDa Cable Co.,Ltd

No.8 Kaiyuan Road Jinan city Shandong province,China 250101

Phone:
86-531-88681868
Fax:
86
Contact:
Marina (export trader)
Mobile:
88681868

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Electric Wire & Cable Made In China Products

,  

Electric Wire & Cable China Suppliers and China Manufacturers