Model: | Customize |
---|---|
Brand: | Theta |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Electronic Measurment Apparatus |
Label: | weather station , weather sensor , 5 in 1weather sation |
Price: |
-
|
Min. Order: | 1 pc |
Live Chat: | Last Online:28 Jul, 2015 |
MP500 is a compact and lightweight multi-sensor instrument that measures 5 essential weather parameters, which mainly including:
1、Wind speed;
2、Wind direction;
3、Barometric Pressure;
4、Air temperature;
5、Relative humidity.
Multi-parameter measurement
MP500 micro meteorological station uses ultrasonic technology to determine wind speed and direction. Barometric pressure is measured using an capcitive sensor.piezo-resistive technology is used to measure the barometric pressure and air temperature by using diode junction voltage sensor.
High accuracy and free-maintenance
MP500 has has no moving parts, and it is resistant to contamination and corrosion.
MP500 measures accurately and produces reliable data in demanding wind conditions and climates without periodic or on-demand maintenance.
Configurable data output
Analog signal output support voltage and current output optional;
Digital signal output support ASCII and MODBUS communication protocol, communication protocol can be customized according to customer's demand.
General Information | |
IP Class | IP65 |
Dimensions | height 234 mm width 160 mm |
Weight | 1.5Kg |
Analog outputs | 4 … 20 mA,1 … 5V |
Digital outputs | 4 … 20mA or 1 … 5V |
Operating voltage | 12 … 30VDC,50mA typical@ 12VDC |
Operating temperature | -40 … +70℃ |
Operating humidity | 5% … 100%RH |
Connector | Aerospace plug |
Connection cable | 5m |
Technical Data | |
Wind Speed | |
Principle | Ultrasonic |
Measurement range | 0 … 60m/s |
Accuracy | ±0.2 m/s or 2% of reading, whichever is greater |
Resolution | 0.1m/s |
Wind Direction | |
Principle | Ultrasonic |
Measurement range | 0 … 359.9° |
Accuracy | ±2° |
Resolution | 0.1° |
Barometric Pressure | |
Principle | Piezoresistor |
Measurement range | 10 … 1100hpa |
Accuracy | ±0.5hpa |
Resolution | 0.1hpa |
Air temperature | |
Principle | Diode voltage |
Measurement range | -40 … +80℃ |
Accuracy | ±0.2℃ |
Resolution | 0.1℃ |
Relative humidity | |
Principle | Capacitive |
Measurement range | 0 … 100% RH |
Accuracy | ±3% RH |
Resolution | 0.10% |