Home > Products > Electronics & Electricity > Power Supply & Distribution > UPS

HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 1HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 2HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 3HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 4HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 5
  • HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 1
  • HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 2
  • HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 3
  • HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 4
  • HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 5

HRD Online Three Phase HF UPS 380/400/415Vac 10-120kVA

Model:PW
Brand:HRD, MOTU
Origin:Made In China
Category:Electronics & Electricity / Power Supply & Distribution / UPS
Label:400Vac UPS , three phase UPS , 60kVA UPS power
Price: US $2100 / pc
Min. Order:1 pc
Inquire Now Add to Basket

Member Information

Detail

Shenzhen HRD SCI & TECH CO., LTD

Free MemberGuang Dong - China
Live Chat:
Last Online:26 May, 2015

Product Description

HRD Onoline Three Phase HF UPS 380/400/415Vac 10-120kVA 

1. Perfect Applications:

Internet Servor, Internet Data Center, Medium-scale network system / computing center, bank and securities, business server group, Medium-scale office automation, precision equipment, etc.

3 Phase UPS brands 10 - 120kva with 0.9PF.jpg

2. Complete Digital Control Technology:

Fully digital control with two DSPs, all the subsystems are digital controlled including the IGBT rectifier, inverter, charger, discharger.

3. Excellent electrical properties:

True online double conversion instruction offers the safe and effective power protection for various loads, with strong output load capacity.

4. High input power factor, green and energy-saving: 

Input end with PFC and input PF of the whole UPS up to 0.99.

5. Dual AC input source supportable: 

Allowable AC and bypass 2 input ac source.

6. Strong environmental adaptability: 

Wide input voltage and frequency range, adaptation to all kinds of climatic and geographical environment.

7. Comprehensive protection measures: 

Surge Protection, short circuit protection, and other protection to ensure the reliability of UPS. IGBT and SCR adopts the advanced EUPEC power module. The adoption of advanced technology (IGBT driving technology, IGBT soft over-current shutdown) improves the reliability and safety of inverter.

8. Similar modular design: 

Each phase main board are designed like rack for easy assembling and maintenance, inbuilt battery pack plug-in design for easy use. 

9. Intelligent battery management (ABM):

Adopting the intelligent battery management. Intelligent interval three-stage charging process( constant current,constant voltage, float charging and charger shut off, when battery voltage decrease to a lower level, charger restarts to work). Automatic temperature compensation,( -0.11% per °C ), to extremely extend battery life by 30% and minimize the maintaining work.

33PHASE UPS.jpg

Online detecting battery status, the max battery charging current can set by end users according to the battery features, to avoid any damage caused by the big charging current; Back up time displayed on the LCD screen. Periodic self-test battery, detecting the battery problems timely. With battery inverse connection, over voltage / current protection, to protect the battery.

10. Superior network monitoring capabilities 

Communication port (RS232, USB, and so on) connecting with computer, SNMP card optional.

11. Easy-maintenance design: 

a) Adopts the full front maintenance design, reducing the restrictions on the installation space, and saving the space of computing center; 

b) Modular design class, convenient and easy site maintenance;

c) With manual maintain bypass;

d) Battery replacement without disrupting the UPS running;

e) Historical records search function, events up to1,000 items.

12. Friendly interface with Large LCD with multi language display (7 languages) 

Large LCD display and LED statu s indication; Abundant information display of UPS English, Spanish, Portugese, Russion.

 

20KVA UPS Power Supply in South Africa 1.jpg

  • Technical Specification: 

Model

PW3310

PW3315

PW3320

PW3330

PW3340

Rating Power

10kVA/9kW

15kVA/13.5kW

20kVA/18kW

30kVA/27kW

40kVA/36kW

AC Input

Rated voltage

380/400/415Vac(Line-Line)

Input connection

3phase +N+PE

Power factor

Above 0.999

THDi

Less 2%

Voltage range

-40%~+25%

Frequency

40-70Hz

Bypass    

+/- 15%(settable)

Output

Power factor

0.9 (lag)

voltage precision

380/400/415Vac±0.5%

Dynamical

voltage transient

Less 5% ( 0~100% load step)

THDU

THD less 0.6%( linear load ),3%(non-linear load)

Crest Factor

3:1

Frequency

tracking range

50/60Hz±3Hz

Output

Frequency precision

 

±0.05%(Battery mode) , ±3hz(Line mode)

phase displacement

120±0.5°(Balance or imbalance load )

Voltage unbalance

+/-3%( 100% unbalance load)

Frequency

tracking rate

Less 1Hz/s

Overload capability

110%: 1hour, 110%<Load<125%, transfer to bypass after 10 minutes

125%<Load<150%, transfer to bypass after 1mins;

above 150%, transfer to bypass after 200ms

Bypass overload

Below125%  long time operation

125%<Load<150%,10mins;above 150% 1S

System

System efficiency

Above 92%(Line and battery mode)

98%(ECO mode)

Display

 Touch screen LCD+LED

 

 

EMC

IEC62040-2

IEC61000-4-2 (ESD)

IEC61000-4-3 (RS)

IEC6100-4-4 (EFT)

IEC6100-4-5 (Surge)

Noise (1m)

50- 60dB

Insulating resistance

Above 2M (500VDC)

Insulating intensity

(input, output to PE) 2820Vdc, leakage current lower than 3.5mA, no flashover in 1min

Surge protection

Meet the requirement of IEC60664-1class,endure surge of 1.2/50us+8/20us higher than 6KV/3KA

IP class

IP20

Battery configuration

Installation(dc)

             +/-216Vdc( 168/192/216/240Vdc settable from LCD screen)

Battery type

Free Maintenance Lead Acid (Gel battery or Ni-Cd)

Long run

Battery to be connected external

Inbuilt battery

36pcs *7ah

36pcs *7ah

36pcs *9ah

72PCS*7ah

72pcs*9ah

Connection

Bottom cable connection in front

Charger

1-15A,ABM technology (settable from LCD)

Physical

Unit Dimension

(Long-run)

390*850*977MM

 (W*D*H)

500×717×1150 MM

(W*D*H)

Unit Dimension

(Inbuilt batt.)

390*850*977MM

 (W*D*H)

500×717×1550 MM

(W*D*H)

Weight (KG)

(Long -run)

110/130

130/150

152/172

160/190

160/190

Weight (KG)

(Inbuilt Batt.)

182/202

202/222

216/236

331/361

367/397

10kva and 15kva:inbuilt 36pcs 7ah

20kva: inbuilt 36pcs 9ah

(72pcs 7ah)

(72pcs 9ah)

 

Model

PW3360

PW3380

PW33100

PW33120

Rating Power

60kVA/54kW

80kVA/72kW

100kVA/90kW

120kVA/108kW

AC Input

Rated voltage

380/400/415Vac(Line-Line)

Input connection

3phase +N+PE

Power factor

Above 0.999

THDi

Less 2%

Voltage range

-40%~+25%

Frequency

40-70Hz

Bypass    

+/- 15%(settable)

Output

Power factor

0.9 (lag)

voltage precision

380/400/415Vac±0.5%

Dynamical

voltage transient

Less 5% ( 0~100% load step)

THDU

THD less 0.6%( linear load ),3%(non-linear load)

Crest Factor

3:1

Frequency

tracking range

50/60Hz±3Hz

Output

Frequency precision

 

±0.05%(Battery mode) , ±3hz(Line mode)

phase displacement

120±0.5°(Balance or imbalance load )

Voltage unbalance

+/-3%( 100% unbalance load)

Frequency

tracking rate

Less 1Hz/s

Overload capability

110%: 1hour, 110%<Load<125%, transfer to bypass after 10 minutes

125%<Load<150%, transfer to bypass after 1mins;

above 150%, transfer to bypass after 200ms

Bypass overload

Below125%  long time operation

125%<Load<150%,10mins;above 150% 1S

System

System efficiency

Above 94%(Line and battery mode)

98%(ECO mode)

Display

 Touch screen LCD+LED

 

 

EMC

IEC62040-2

IEC61000-4-2 (ESD)

IEC61000-4-3 (RS)

IEC6100-4-4 (EFT)

IEC6100-4-5 (Surge)

Noise (1m)

50- 60dB

Insulating resistance

Above 2M (500VDC)

Insulating intensity

(input, output to PE) 2820Vdc, leakage current lower than 3.5mA, no flashover in 1min

Surge protection

Meet the requirement of IEC60664-1class,endure surge of 1.2/50us+8/20us higher than 6KV/3KA

IP class

IP20

Battery configuration

Installation(dc)

  +/-216Vdc( +/-168/192/216/240Vdc ,settable from LCD screen)

Battery type

Free Maintenance Lead Acid (Gel battery or Ni-Cd)

Connection

Bottom cable connection in front

Charger

10-40A( settable from LCD screen)

Physical

Unit Dimension

(UPS)

600×850×1680 MM (W*D*H)

735×850×1680 MM (W*D*H)

Unit Dimension

(Packing)

954×704×1857 MM (W*D*H)

954×839×1857 MM (W*D*H)

Weight N/G (KG)

240/280

260/300

320/360

340/380

Packaging & Shipping

 20KVA UPS Power Supply in South Africa.jpg3 Phase UPS System 10 - 120kva 5.jpg

Three Phase 10 kva UPS 10kw with Similar Modular Design 4.jpg

  

Three Phase 10 kva UPS 10kw with Similar Modular Design.jpg

 

Online Numeric UPS 208v 3phase UPS.jpg

Our Services

  1. 1.5% spare parts of quantity with delivered with UPS
  2. Software is optional for three Phase HF UPS Power 50kva with Bypass
  3. OEM/ODM: allowing to use the customer logo based on order quantity
  4. Warranty for 2 years from shipment date
  5. If any part fails within warranty and needs repairing or replacing, please send part or board back to us (you pay for the freight), Or you provide the exact details information as per our requriment, and we offer you free spare parts and send to you ( you pay the freight fee)

20KVA UPS Power Supply in South Africa 3 .jpg

 

FAQ

20KVA UPS Power Supply in South Africa 4.jpg

What is the difference between high frequency UPS and low frequency UPS?

Item

High frequency UPS

Low frequency UPS

Input PF

0.99

0.7

Efficiency

85-90%

75-85%

Power density

Higher

Lower

Power device capacity

Less

More

Weight

Light

Heavy

Dimension

Compact

Bigger

Price

Lower

Higher

Overload ability

Normal

Better

Anti input sugar capacity

Normal

Better

Output anti-crush , short circuit capacity

Normal

Better

N-G voltage

Bad

Better

Output component

More

Less

Damage extent of device when it’s fail

Higher

Lower

Stability

Normal

Better

 

Certifications

 20KVA UPS Power Supply in South Africa 5 .jpg

Company Information

20KVA UPS Power Supply in South Africa 1.jpg

20KVA UPS Power Supply in South Africa2.jpg

Trade Shows

2014 GITEX

208vac UPS Made in China for South America.jpg

After-Sales Service

HRD high qualtiy UPS successfully installed

for the National Grand Theatre of AlgeriaRack Mount UPS with 1 Hour Backup.jpg


Product Image

HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 1
Img 1
HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 2
Img 2
HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 3
Img 3
HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 4
Img 4
HRD Online Three Phase HF UPS 380/400/415Vac  10-120kVA 5
Img 5

Send Inquiry to this Member

Shenzhen HRD SCI & TECH CO., LTD

No. 7 building Changxing high-tech industrial park, Shajing town Bao'an district, Shenzhen, China

Phone:
86-0755-81737467
Fax:
86-0755-81737252
Contact:
Penny (Sales)
Mobile:
13265429579

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

UPS Made In China Products

,  

UPS China Suppliers and China Manufacturers