7kW rectifier AC input 220V to DC output 100-750V battery charger for Lithium battery/Lead Acid Battery Charging
Product Introduction:
SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 50 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.
Unique function:
Main features:
Product Parameters (SINGLE PHASE INPUT)
Model |
SD75020S |
|
AC input |
Input phase |
Single phase L/N or L1/L2 + PE |
Voltage rage |
187-260Vac |
|
Rated voltage |
220Vac |
|
Frequency range |
50Hz/60Hz |
|
Maximum current |
<32A |
|
DC output |
DC Voltage range |
50~750Vdc |
Output power |
7KW@ voltage >350VDC |
|
Output DC current (A) |
1~20A (can set) |
|
Output DC current range(A) |
10~300A (customizable) |
|
Steady voltage precision |
<±0.5% |
|
Steady current precision |
≤±1% (rated range of 20% ~ 100% for output load) |
|
Load regulation rate |
≤±0.5% |
|
Grid regulation rate |
≤±0.1% (testing range is 320V ~ 530V) |
|
Startup overshoot |
≤±3% |
|
Power factor and THD |
Power factor |
≥0.95 Full-load output power of @20%~50% |
≥0.98 Full-load output power of @50%~100% |
||
≥0.99 Full-load output power, input nominal voltage and frequency of @100% |
||
THD |
≤5% Full-load output power of @50%~100% |
|
Efficiency |
≥94.5%, @750V, 50%~100% load current, under rated input voltage |
|
Protection function |
input overvoltage Protection |
Over Under Voltage automatic shutdown and restart when voltage return normal |
Output overvoltage protection |
Over Under Voltage automatic shutdown and restart when voltage return normal |
|
Over-temperature protection |
Automatic shutdown. Automatic restart when the temperature return to normal |
|
Short circuit protection |
Automatic shutdown and lock, need power off to restart to unlock |
|
Noise |
≤65dB(A) (1m away) |
|
Application place |
Indoor (IP20) |
|
Environmental conditions |
Operating temperature |
-40°C ~ +75°C, derating is required when the temperature is above 55°C. |
Storage temperature |
-40℃ ~ +70℃ |
|
Relative humidity |
≤95%RH, No condensation |
|
Cooling way |
Forced air cooling |
|
Altitude |
2000m, derating is required when the altitude is above 2000 m |
|
Mechanical parameters |
Size |
87Mm (H) ×178mm (W) ×385mm (D) |