Model: | EJA110 |
---|---|
Brand: | Yokogawa |
Origin: | Made In Japan |
Category: | Electronics & Electricity / Electronic Instrument / Pressure Gauge |
Label: | pressure transmitter , pressure guage , pressure measuring |
Price: |
-
|
Min. Order: | 1 pc |
Live Chat: | Last Online:01 Apr, 2015 |
Differential Yokogawa EJA 110 Pressure Transmitter
The high performance differential Differential Yokogawa EJA 110 Pressure Transmitter can be used to measure liquid, gas, or steam flow as well as liquid level, density and pressure. It outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure.
The EJA Series is available with BRAIN, HART, FOUNDATION fieldbus or PROFIBUS PA communication protocols.
Feature
-- Excellent performance and stability:
The Yokogawa 4-20ma Differential Pressure Transmitter EJA110A uses a formed from monocrystal silicon, a perfect material which has no hysteresis in pressure or temperature changes. The sensor minimizes overpressure, temperature change, and static pressure effects, and thus offers unmatched long-term stability.
-- Compact and light-weight design
Half the weight of conventional models thanks to miniaturization of the casing with the amplifier ASIC, pressure cell structure, and flange. The ASIC uses the minimum number of parts and improves the reliability of the amplifier.
-- Fieldbus communication capability
Fieldbus is a digital two-way communication system. It is a revolutionary technology for configuring instrumentation control systems and a promising successor to the standard 4 to 20 mA analog communication used in most field instruments today. manufactures.
Specific
specification | |||||
EJA110A Differential Pressure Transmitter | |||||
L Capsule | M Capsule | H Capsule | V Capsule | ||
Range | -10 to 10 kPa | -100 to 100 kPa | -500 to 500 kPa | -0.5 to 14 MPa | |
(-40 to 40 inH2O) | (-400 to 400 inH2O) | (-2000 to 2000 inH2O) | (-70 to 2000 psi) | ||
Span | 0.5 to 10 kPa | 1 to 100 kPa | 5 to 500 kPa | 0.14 to 14 MPa | |
(2 to 40 inH2O) | (4 to 400 inH2O) | (20 to 2000 inH2O) | (20 to 2000 psi) | ||
Accuracy | ±0.075% | ±0.065% | ±0.065% | ±0.065% | |
Degrees of protection | IP67, NEMA 4X, and JIS C0920 immersion proof | ||||
Certificates | FM, CENELEC ATEX, CSA, IECEx | ||||
Output | 4 to 20 mA DC, FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication | ||||
Supply voltage | BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) | ||||
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model) | |||||
Ambient temperature | -40 to 85 deg C (-40 to 185 deg F) (general use type) | ||||
-30 to 80 deg C (-22 to 176 deg F) (with integral indicator) | |||||
Process temperature | -40 to 120 deg C (-40 to 248 deg F) (general use type) | ||||
Maximum working pressure | 16MPa(2300psi) | ||||
3.5MPa(500psi) for L capsule with special materials | |||||
Mounting | 2-inch pipe mounting | ||||
Wetted parts material | Capsule | SUS316L(Diaphragm material is Hastelloy C-276), | |||
Hastelloy C-276, Tantalum, Monel | |||||
Cover flange | SUS316, Hastelloy C-276, Monel | ||||
Housing | Cast aluminum alloy or SUS316 equivalent stainless steel (optional) |