Model: | NGW113-500 |
---|---|
Brand: | Boxiang |
Origin: | Made In China |
Category: | Industrial Supplies / Machinery / Transmission |
Label: | reducer NGW113-500 , speed reducer NGW113 , gear speed reducer N |
Price: |
US $3000
/ pc
|
Min. Order: | 1 pc |
Live Chat: | Last Online:24 Mar, 2014 |
Main features of speed reducer NGW113-500
1. Light weight, small size.
2. Wide transmission power range, from 1KW to 1300KW.
3. Using carbide-face technology, long service lifetime, wide application.
4. It is above 2 times lighter in weight, 2-3 times smaller than ordinary cylinder gear speed reducer.
5. High transmission efficiency. Single stage efficiency is 0.97. Two-stage is 0.94. Three-stage is 0.91.
Working conditions of speed reducer NGW113-500
1. Maximum rotating speed of high speed shaft doesn't exceed 1500r/min.
2. Gear periphery speed doesn't exceed 10m/s.
3. Suitable for normal-reverse rotation.
4. Working temperature -40℃-50℃.
Wide applications of speed reducer NGW113-500
Widely used in metallurgy, mine, chemical industry, construction materials, hoisting, transportation, textile, paper making, food, plastic, rubber, engineering machinery, and energy industry.
Company introduction of speed reducer NGW113-500
We have been in speed reducer industry since 1999. We're a manufacturer of different speed reducers. We're devoted to provide professional s estions and great service to every our client.
We have established partnership with customers from India, Belgium, Malaysia, Burma, Finland, Tunisia, Ukraine, Canada etc. Looking forward to cooperating with your esteemed company.
Maintenance period |
|
1. Check oil temperature | Everyday |
2. Check abnormal noise of gear units | |
3. Check oil level | Every month |
4. Check leakage | |
5. Analyse water | Every 400 working hours. At least 1 year. |
6. Replace oil first time after start up | Every 400 working hours |
7. Afterward oil replacement | Every 18 months or 5000 working hours. |
8. Clean oil filter | Every 3 months |
9. Clean breather screw | |
10. Clean fan, fan shield and housing | At the same time as replacing oil |
11. Check residues in cooling coil | Every 2 years and the same time as replacing oil |
12. Check air-cooling devices | At the same time as replacing oil |
13. Check water-cooling devices | |
14. Check tightening bolt | After first replacing oil, every 2 times of replacing oil |
15. Make an over all check | Every 2 years and coincide with replacing oil |
Model | NGW series |
Certificate | ISO9001:2008, ZJQC |
Stage | Three |
Tooth surface hardness | Hard |
Layout form | Coaxial type |