Home > Products > Electronics & Electricity > Power Transmission Equipment & Transformer

Gas Insulated Capacitor Voltage Transformer 1Gas Insulated Capacitor Voltage Transformer 2
  • Gas Insulated Capacitor Voltage Transformer 1
  • Gas Insulated Capacitor Voltage Transformer 2

Gas Insulated Capacitor Voltage Transformer

Model:TYDL 220/√3 - 0
Brand:SIHU
Origin:Made In China
Category:Electronics & Electricity / Power Transmission Equipment & Transformer
Label:Gas Insulated VT , Capacitor VT , Voltage Transformer
Price: -
Min. Order:1 pc
Inquire Now Add to Basket

Member Information

Detail

Guangdong Sihui Instrument Transformer Works Co., Ltd.

Free MemberGuang Dong - China
Live Chat:点击这里给我发消息Last Online:17 Mar, 2015

Product Description

Product Name: Gas Insulated Capacitor Voltage Transformer.

Technical Parameters for TYDL 220/√3 - 0.005H SF6 Capacitor Voltage Transformers

1 Rated primary voltage 220/√3kV

2 Highest voltage for equipment 252kV

3 Rated frequency 50(60)Hz

4 Rated insulation level 252/460/1050kV

5 Rated secondary voltage

a) Measuring secondary winding 0.1/√3kV

b) Protective secondary winding 0.1/√3kV

c) Residual voltage winding 0.1kV

6 Rated operating pressure of gas SF6 is 0.40MPa

7 Minimum operating pressure of the gas SF6 is 0.35MPa

8 Rated output and relative accuracy class (cosΦ=0.8 lag) see Table 1

Table 1 Rated Output and Relative Accuracy Class of Instrument Transformer

 

Winding Measuring Winding Protective Winding Residual Voltage Winding
Terminals Marking 1a-1n 2a-2n 3a-3n da-dn
Accuracy Class 0.2 0.5 0.5 3P 0.5 3P 3P
Rated Output (VA) 100 - 150 - - - 300
- 150 - 250 - - 300
75 - 100   - 75 300

 

Notes:

A. The Windings quantity, rated output and accuracy listed above can be designed according to the requirements of the clients;

B. Thermal limit load of each protective winding is 2000 VA.

9 The system earthing mode is effectively earthed neutral system

10 Arcing distance ≥2320mm

11 Creepage distance of outer insulation see Table 2

Table 2 Creepage Distance of Outer Insulation

Pollution Protection Class

Class II

Class III

Class IV

Creepage Distance (mm)

≥5040

≥6300

≥7812

 

12 Rated capacitance (CN) of the capacitor voltage divider is 0.005μF; Rated capacitance (C1N) of the high voltage capacitor of the capacitor divider is 0.006546114μF;

Rated capacitance (C2N) of the intermediate voltage capacitor of the capacitor divider is 0.0211695μF.

13 The capacitance tolerance of the capacitor divider CN shall not exceed -5%~+10% of rated capacitance; the capacitance tolerance of the high voltage capacitor C1 shall not exceed -5%~+10% of rated capacitance; the capacitance tolerance of the intermediate voltage capacitor C2 shall not exceed ±5% of rated capacitance.

14 The voltage ratio of a capacitor divider shall not exceed ±5% of its rated value.

Notes: Detailed technical data and outline and stallation drawing can be provided under request.


Payment Terms:TT/LC
Packing:wooden cases
Lead Time:30dyas
Loading Info:Good are always delivered on time.We have our own transportation department.Good can be delivered whenever they are ready.

Product Image

Gas Insulated Capacitor Voltage Transformer 1
Img 1
Gas Insulated Capacitor Voltage Transformer 2
Img 2

Send Inquiry to this Member

Guangdong Sihui Instrument Transformer Works Co., Ltd.

No. 8 Fuhua Road , Dongcheng Street , Sihui City , Guangdong Province, China

Phone:
86-758-3233639
Fax:
86-758-3231206
Contact:
Willie (Technology )
Mobile:
13435857965

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Power Transmission Equipment & Transformer Made In China Products

,  

Power Transmission Equipment & Transformer China Suppliers and China Manufacturers