Home > Products > Electronics & Electricity > Electronic Instrument > Air & Gas Flowmeter

Coriolis Mass Flow Meter 1
  • Coriolis Mass Flow Meter 1

Coriolis Mass Flow Meter

Model:-
Brand:KCCV
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Air & Gas Flowmeter
Label:flow meter , flowmeter , flow instrument
Price: -
Min. Order:10 pc
Inquire Now Add to Basket

Member Information

Detail

Jiangsu KCCV Co.,LTD

Free MemberJiang Su - China
Live Chat:Last Online:27 Dec, 2013

Product Description

1. Introduction

KC-CMFI Coriolis Mass Flow Meters patented and developed by our company are the leading meters for precision flow measurement. And with good reason, KC meters offer the most accurate measurement available for virtually any process fluid, while exhibiting exceptionally low pressure drop. KC meters offer direct mass flow, volume flow, density, and temperature measurement of liquids and slurries — without the need for additional equipment, manual calculations, or estimations.

KC meters are designed for unsurpassed performance in even the harshest operating environments. They have no moving parts, and any special mounting or flow conditioning requirements. Every KC meter is available with stainless steel wetted parts and a wide variety of process connections to meet your every need.

KC meters carry hazardous area approval for P. R. China.

 

2. Principles of Measurement

The structure of KC-CMFI Coriolis Mass Flow Meters was consisted of a pair of bended tubes. The principle is to detect Coriolis force forced a pair of tubes from inner mass flow by fluid.

A new force—Coriolis force would be appear while two conditions met: (1) vibrating with normal frequency in a pair of bended tubes, (2) fluid flowing in tubes. This force was produced upon synthesis from vibrating force and flowing force by fluid in tubes. And tubes would be wresting symmetric the center line because the force forced. Two displacement sensors on sides of tubes detect the force and output electric signals. The signals regulated, mass flow directly produced.

 

3. Technical Specifications of Products

3.1 Technical Specifications

Table of Technical Specifications (Table 1)

 

Titles

Technical Specifications

Mass flow accuracy

±[0.2% +zero stability /flow rate×100%]

Mass flow repeatability

±(1/2) ×[0.2% +zero stability /flow rate×100%]

Density range

0.2 g/cm33.5g/cm3

Density accuracy

±0.002g/cm3

Temperature range

-60℃+200℃

Temperature accuracy

±1℃

Output of current loop

4mA20mA

Output of frequency/pulse

0Hz10kHz

Contactor capacity of a Batch Control relay

24V/0.1A

Contactor form

normal open (would be changed to normal close while special order)

 

3.2 Other Specifications

Environmental Specifications (Table 2)

Titles

Specifications

Temperature range of fluid

-40℃+200℃

Environmental temperature range

0℃+40℃

Environmental humidity

≤90% RH, non condensation

Atmospheric pressure range

86kPa106kPa

Power supply of transmitters

Essential safety Voltage: AC(220±10%)V,(50±5%)Hz

Composite Voltage: DC (24±10%) V

Power consumed

15W

 

Specifications (Table 3)

Specs

Line Sizes (mm)

Flow Range(t/h)

Calibration Range(t/h)

Max. Tube Pressure (MPa)

Zero Stability (t/hr)

Velocity  Parameter

(h m/t s)

DN6

6

00.9

0.90.9

4.0

0.00016

19.65

DN10

10

03.5

0.353.5

4.0

0.0002

4.912

DN15

15

08

0.88

4.0

0.0011

2.183

DN25

25

020

220

4.0

0.002

0.902

DN40

40

052

5.252

4.0

0.003

0.334

DN50

50

080

880

4.0

0.006

0.197

DN80

80

0200

25200

2.5

0.01

0.0873

DN100

100

0320

32320

2.5

0.015

0.0544

 

 

3.3 Explosion-proof Identification Code

Teble of Explosion-proof identification code (Table 4)

Form of Explosion-proof

Identification Code

Essential safety

Exib[ib]IIBT4

Composite

Exdib[ib]IIBT4

 

 

4. Conditions required of installation

To guarantee the accuracy, conditions required when installation should be met, because the mass flow meter type of KC-CMFI is a high precision instrument:

(1) The sensor (primary meter) and the transmitter (secondary meter) do not install in strong magnetic interferential area. Or, measuring signals would be disturbed, and debase the accuracy;

(2) There is must not any other vibrator on line installed the sensor (primary meter);

(3) If install outside of door, PLS pay attention circumstance temperature not to exceed the range of meter, and should consider to build a weatherproof shield to avoid blowing and drenching, for increasing lifetime of flow meter.

(4) The transmitter (secondary meter) of essential safety should mount in safety area or appropriate control room.

(5) A shield cable with ten core lines connects the sensor (primary meter) and the transmitter (secondary meter) of essential safety.

The output cable of the transmitter (secondary meter) of composite is a shield cable with ten core lines.

Five meters long of the cable is normal option in package by our company. Customs can deal special order for longer cable, but not exceed 200 meters.

 


Product Image

Coriolis Mass Flow Meter 1
Img 1

Send Inquiry to this Member

Jiangsu KCCV Co.,LTD

No.379,Shenhua Road,Jinhu,Jiangsu,China

Phone:
86-517-86989599
Fax:
86-517-86989299
Contact:
Renee Wang (Sales Manager)
Mobile:
15183599

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Air & Gas Flowmeter Made In China Products

,  

Air & Gas Flowmeter China Suppliers and China Manufacturers