Intelligence PDU 1
  • Intelligence PDU 1

Intelligence PDU

Model:MFT-NP3V-H12NFE
Brand:MFT
Origin:Made In China
Category:Electronics & Electricity / Telecommunication & Broadcasting / Network Communications Equipment
Label:Intelligence PDU , Switch PDU , Metered PDU
Price: -
Min. Order:1 pc
Inquire Now Add to Basket

Member Information

Detail

Maxfor Technology Co.,Ltd

Free MemberGuang Dong - China
Last Online:20 Jul, 2014

Product Description

Model:  MFT-NP3V-H12NFE

Configuration
Installation Mode: Vertical Installation
Output Standard: 16A IEC320 C19 Socket (4ways), IEC320 C13 Clip-on Socket (8ways)
Rated Input Current: 32A
Input Standard:  32A(2P+E) Industry plug
Cable Dimension:   3×6.0mm2×2M
 

Functions
Remote Access Method:

Supply the Standard romote management function which basic on Web, SNMP and Telnet management interface for customers, Customers can access, set and manage NPDU through the website.
 

Remote Monitoring Function:

1. Total load Current and Voltage.
2. Total Electric Energy use level in Unit time.
3. Total load power and power factor.
4. The current,Voltage and Power of each output unit.
5. The inside humidity,smog, access control and water logging status of the cabinet( need to match sensor).
 

Remote Control Function:

1. Each output unit open and close controlling.
2. The time setting of output unit open&close in turn, interval, delay.
3. The time setting of out put timing open, close.
4. when give an alarm for overload, the system prompt operation info that Wheather cut down output power or not.
 

Alarm Threshold Setting Function:

1. The total load current,a upper limit/lower limit threshold value.
2. The load current of each output unit, a upper limit/lower limit threshold value.
3. Temperature and humidity,a upper limit/lower limit value.


Overload,Overrun give a Alarm automatic function:

1.The Total load current over rated.
2.The Each output unit load current over rated.
3.Temperature and humidity over rated(should match with  sensor.
4.Smog occurence( need to match sensor).
5.Water logging occurence( need to match sensor).
6.Access control open occurence( need to match sensor).


Alarm Threshold Setting Function:

1. Local control panel indicator flicker, speaker buzzing.
2. Web Interface give an alarm, PC speaker buzzing.
3. Sending E-mail to system adminstrator automaticlly.
4. Logic output port output level signal.
5. Sending message to system adminstrator through mobile phone.(Binding mobile phone through E-mail)
6. SNMP send Alarm status messages.
 

Inquery

1. Operating Log query.
2. Alarm log query.
 

Others: User Rights Setting.


Product Image

Intelligence PDU 1
Img 1

Send Inquiry to this Member

Maxfor Technology Co.,Ltd

ROOM 706,7/F,BUILDING 7, YINGSHUI VILLAGE 2 ZONE, MINLE, LONGHUA DIST, SHENZHEN,518131 CHINA

Phone:
86-755-28132323
Fax:
86-755-28097922
Contact:
Selina Lee (Sales Manager)
Mobile:
13728695377

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Network Communications Equipment Made In China Products

,  

Network Communications Equipment China Suppliers and China Manufacturers