Home > Products > Electronics & Electricity > Power Supply & Distribution > Other Power Supply & Distribution

GAC load sharing module LSM672N 1GAC load sharing module LSM672N 2GAC load sharing module LSM672N 3GAC load sharing module LSM672N 4GAC load sharing module LSM672N 5GAC load sharing module LSM672N 6GAC load sharing module LSM672N 7GAC load sharing module LSM672N 8GAC load sharing module LSM672N 9GAC load sharing module LSM672N 10GAC load sharing module LSM672N 11GAC load sharing module LSM672N 12
  • GAC load sharing module LSM672N 1
  • GAC load sharing module LSM672N 2
  • GAC load sharing module LSM672N 3
  • GAC load sharing module LSM672N 4
  • GAC load sharing module LSM672N 5
  • GAC load sharing module LSM672N 6
  • GAC load sharing module LSM672N 7
  • GAC load sharing module LSM672N 8
  • GAC load sharing module LSM672N 9
  • GAC load sharing module LSM672N 10
  • GAC load sharing module LSM672N 11
  • GAC load sharing module LSM672N 12

GAC load sharing module LSM672N

Model: LSM672N
Brand:GRAIGAR
Origin:Made In China
Category:Electronics & Electricity / Power Supply & Distribution / Other Power Supply & Distribution
Label:load sharing module , LSM672N , GAC load sharing
Price: US $130 / pc
Min. Order:1 pc
Inquire Now Add to Basket

Member Information

Detail

Shenzhen Graigar Technology Co., Limited

Biz MemberGuang Dong - China
Live Chat:
点击这里给我发消息Last Online:20 Oct, 2023

Product Description

LSM672N Load Sharing Module Diesel Generator Electronic Load Controller 

 

 

 

 

 

1)Description----

 

The function of the Load Sharing Module is to proportionally share load between two or more generator sets while the system frequency is held constant.As an accessory to the electronic Governing System,the PER 672 measures the true power current ,and throught a parallel cable interconnection,continuously controls the governor system.

 

 

2)Performance:


Load SharingAdjustable to within +/-2% between sets 
Performance.Isochronous and droop paralleling and power control 
Reverse Power Monitor.Adjustable from 0.5-20% with a 2 second inverse time constant 
Forward Power MonitorONtrip point adjustable from 20-100%                        
                                            OFFtrip point adjustable from 0-80%                   
                                               Normally open contacts with a 2 second inverse time constant

3)Power Output:

Signal.0 to 7.5 Volts DC representing 0-100% load 
All performance specifications are based on 5 amps from the current transformer(CT) Secondaries at full load unity P.F.

 

4)Power input :
AC input signals.. 208 or 416 volt nominal line to line and 5 amp CTs with a minimum 6.25 VA rating. Internal 0.25 ohm burden resistors 
Line to line voltagesper table below             
HZ      LOW RANGE       HIGH RANGE            
50      140-250 VAC         260-420 VAC             
60      170-260 VAC         340-500 VAC            
400     170-260 VAC         340-500 VAC

DC Supply..18-36 VDC(Transient and reverse voltage protected)
 DC Power Consumption.70 ma continuous

5)Weight: 2.41kg

 

6)Relative products:

 

PER672

PER6714

Power Input  AC Input Signals  208 or 416 Volt nominal line to and 5Amp Cts with a minimun 6.25VA 
 Rating internal 0.25 ohm burden resistors 
 Line to line Voltages  Per table below
 DC Supply  18-36 VDC (Transient and reverse voltage protected) for 12 VDC 
 Applicationis use LSM 672-12
 Polarity  Negative ground (case isolated)
 DC Power Consumption  70 ma continuous
 Power output Signal  0-7 Volts based on 5amps of C.T .output
Performance  Load sharing   Adjustable to within ±2% between sets
 Performance  Isochronous and droop paralleling and power contol
 Reverse Power Monitor  Adjustable from 0.5-20% with a 2 second inverse time constant
 Forward power Monitor  "ON" trip point adjustable from 20-100%/ "OFF" trip point adjutable 
 From 20-100%. Normally open contacts with a 2 second inverse time 
 Constant
 Power output Signal  0 to 7.5 Volts DC representing 0-100% load. All performance 
 Specifications are based on 5A from the current transformer(CT) 
 Secondaries at full load unity P.F.
 Droop Range   1-5% regulation
Environmental  Temperature Range  -40 to +175°F(-40°+85 °C)
 Relative Humidity  100%- Circuit board heavily conformal coated
 All Surface Finishes  Fungus Proof and Corrosion Resitant
Reliability  Testing  100% Functional Tested
 Vibration  1g @ 20-100HZ
 Shock  10gs
physical   Dimensions  See Diagram 1
 Weight  5.2 Lbs (2.36Kgs)
 Mounting  Any position, Vertical Preferred

Product Image

GAC load sharing module LSM672N 1
Img 1
GAC load sharing module LSM672N 2
Img 2
GAC load sharing module LSM672N 3
Img 3
GAC load sharing module LSM672N 4
Img 4
GAC load sharing module LSM672N 5
Img 5
GAC load sharing module LSM672N 6
Img 6
GAC load sharing module LSM672N 7
Img 7
GAC load sharing module LSM672N 8
Img 8
GAC load sharing module LSM672N 9
Img 9
GAC load sharing module LSM672N 10
Img 10
GAC load sharing module LSM672N 11
Img 11
GAC load sharing module LSM672N 12
Img 12

Send Inquiry to this Member

Shenzhen Graigar Technology Co., Limited

Xinfu Building,Center Road,Shajing Street,Baoan District

Phone:
86-0755-27541660
Fax:
86-0755-23728063
Contact:
Leo Lee (Sales Manager)
Mobile:
15967476818

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Other Power Supply & Distribution Made In China Products

,  

Other Power Supply & Distribution China Suppliers and China Manufacturers