Multi-parameter Touch-screen Monitor

Model:JH200
Brand:-
Origin:Made In China
Category:Home Supplies / Personal Care Appliance
Label:patient monitor , oximeter , pulse oximeter
Price: US $900 / pc
Min. Order:1 pc
Inquire Now Add to Basket

Member Information

Detail

Z AND Y INTERNATIONAL CO., LIMITED

Free MemberBeijing - China
Live Chat:Last Online:01 Jul, 2013

Product Description

Features:

Can monitor six parameters: ECG,RESP,NIBP,SPO2,TEMP,Pulse Rate.

1. 20 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titration table;

2. Efficient resistance to interference of defibrillator and electrosurgical cautery;

3. SPO2 can testing for 0.1% Weak;

4. RA-LL impedance Respiration;

5. Trend Coexist Display;

6. OxyCRG DyNamic View Display;

7. Options of printing, IBP, VGA and EtCO2;

8. UP to 4 hours working capacity of built_in Li-ion rechargeable battery;

9. 8.4" high resolution color TFT LCD Touch-Screen display;

10. Large volume of tabular and graphic trends information storage and easy to recall;

11. Anti-ESU, anti- defibrillator;

12. 6 Standard parameters:ECG,RESP,NIBP,SPO2,1_TEMP,PR/HR;

13. Capture dynamic waveforms.


Standard Packing List:

Main unit

5-lead ECG cable ( including RESP/Surface TEMP sensor)

Adult finger SpO2 sensor

Adult NIBP cuff

NIBP extension tube

AC Adapter

ECG electrodes

Operation instruction

Touch Pen

Wall bracket

Selectable Accessory:

Child finger SPO2 sensor

Child NIBP cuff

Neonate NIBP cuff


H.S.Code:90181930

Dimension:240X170X70mm

Net Weight:1.40kg

Gross Weight: 3.00kg

Package Size: 29.0X22.0X25.0cm

Color: White
Technical specification




Product Specification

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection: I, II, III, avR, avL, avF, V,

Waveform: 2 ch

Lead mode: 3 Leads ( R, L, F or RA, LA, LL)

Lead selection: I, II, III,

Waveform: 1 ch

Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto

HR and Alarm

Range

Adult: 15 ~ 300 bpm

Neo/Ped: 15 ~ 350 bpm

Accuracy: ± 1% or ± 1bpm,which great

Resolution: 1 bpm

Sensitivity: > 200 (uV P-P)

Differential Input Impedance: > 5 MΩ

CMRR

Monitor: > 105 dB

Operation: > 105 dB

Diagnosis: > 85 dB

Electrode offset potential: ±300mV

Leakage Current: < 10 uA

Baseline Recovery: < 3 S After Defi.

ECG Signal Range: ±8 m V ( Vp-p )

Bandwidth

Surgery: 1 ~ 15 Hz

Monitor: 0.5 ~ 35 Hz

Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p), Accuracy:±5%

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available

Review: Available



RESPARATION

Method: Impedance between R-F(RA-LL)

Differential Input Impedance: >2.5 MΩ

Measuring Impedance Range:0.3~5.0Ω

Base line Impedance Range: 0 – 2.5 KΩ

Bandwidth: 0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range

Adult: 0 ~ 120 rpm

Neo/Ped: 0 ~ 150 rpm

Resolution: 1 rpm

Accuracy: ±2 rpm

Apean Alarm: 10 ~ 40 S



NIBP

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and alarm range

Adult Mode

SYS: 40 ~ 270 mmHg

DIA: 10 ~ 215 mmHg

MEAN: 20 ~ 235 mmHg

Pediatric Mode

SYS: 40 ~ 200 mmHg

DIA: 10 ~ 150 mmHg

MEAN:20 ~ 165 mmHg

Neonatal Mode

SYS: 40 ~ 135 mmHg

DIA:10 ~ 100 mmHg

MEAN:20 ~ 110 mmHg

Resolution Pressure:1mmHg

Accuracy Pressure Maximum Mean error: ±5mmHg

Maximum Standard deviation: ±8mmHg

Overpressure Protection

Adult Mode: 297±3 mmHg

Pediatric Mode: 240±3 mmHg

Neonatal Mode: 147±3 mmHg



SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100% ±2 %

0% ~ 69% unspecified

Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate

Measuring and Alarm Range: 20~300bpm

Resolution: 1bpm

Accuracy: ±2bpm



TEMPERATURE

Channel: 1

Measuring and Alarm Range: 0 ~ 50 °C

Resolution: 0.1°C

Accuracy: ±0.1°C

Actualization interval: about 1 Sec.

Average Time Constant:<10 Sec.

Product Image

Multi-parameter Touch-screen Monitor 1
Img 1
Multi-parameter Touch-screen Monitor 2
Img 2
Multi-parameter Touch-screen Monitor 3
Img 3
Multi-parameter Touch-screen Monitor 4
Img 4

Send Inquiry to this Member

Z AND Y INTERNATIONAL CO., LIMITED

Beijing Changping District Long Yuesan Huilongguan district

Phone:
86-15711128827
Fax:
86
Contact:
jason guo (manager)
Mobile:
15711128827