1. General Information
1.1 Ballast identification HYQ 2×14-35/220-240 L358D-C
1.2 Designed for lamp T5-E 14W×2/ T5-E 21W×2/ T5-E 28W×2/ T5-E
35W×2 conform to IEC60081
1.3 Number of lamps 2 pieces
1.4 Operation with one lamp removed Ballast not working
1.5 Suitable for luminaries Luminaries of class I
2. Input (Mains) Specifications
2.1 Nominal voltage 220-240V
2.2 Nominal frequency 50/60Hz
2.3 Min. AC voltage for starting 0℃~50℃,190V start-up;-10℃~50℃,220-240V start-up
2.4 AC operation on 198~253V
2.5 Rated input power ≤84W ,230V
2.6 Power factor ≥0.93 ,230V
3. Application environment temperature&humidity
3.1 Lowest application environment temperature (Inside the luminaries) -15℃
3.2 Highest application environment temperature (Inside the luminaries) 60℃
3.3 Highest temperature of ballast case when working normally 80℃
3.4 Lowest application environment humidity (Inside the luminaries) 15%
3.5 Highest application environment humidity (Inside the luminaries) 70%
4. Safety Requirements
4.1 Marking IEC/EN 61347-1、GB19510.1
4.2 Protection against contact with live parts IEC/EN 61347-1、GB19510.1
4.3 Terminals IEC/EN 61347-1、GB19510.1
4.4 Provisions for earthing IEC/EN 61347-1、GB19510.1
4.5 Moisture resistance and insulation IEC/EN 61347-1、GB19510.1
4.6 Dielectric strength IEC/EN 61347-1、GB19510.1
4.7 Fault conditions IEC/EN 61347-1、GB19510.1
4.8 Protection of associated components IEC/EN 61347-2-3、GB19510.4
4.9 Abnormal conditions IEC/EN 61347-2-3、GB19510.4
4.10 Creepage distances and clearances IEC/EN 61347-1、GB19510.1
4.11 Screws,current-carring parts and connections IEC/EN 61347-1、GB19510.1
4.12 Resistance to heat, fire and tracking IEC/EN 61347-1、GB19510.1
4.13 Resistance to corrosion IEC/EN 61347-1、GB19510.1
5. ElectromagneticCompatibility (EMC)
5.1 Limits for harmonic current emissions IEC/EN 61000-3-2、GB17625.1
5.2 Limits and methods of measurement of radio IEC/EN 55015、GB17743
disturbance characteristics of electrical lighting
and similar equipment
5.3 Equipment for general lighting purpose-EMC IEC/EN61547、GB/T18595
Immunity requirements
6. Installation and Wiring
6.1 Terminals Push-in type with test contact
6.2 Cross section of wires (mm²)(any lead) 0.5~0.75mm2
6.3 Max. allowed lamp cable length (m) 2m
6.4 Min distance ballast to ballast (cm) 5cm
7. Ballast Case
7.1 Case material and identification Metal、L358D-C
7.2 Approx. dimensions (mm) MaxL1358×W30×H21mm
7.3 Mounting hole distance (mm) L2348mm
7.4 Mounting screws M4 max.
7.5 Ground connection via Functional connection by push-in wire
8. Certifications
8.1 Certifications VDE,ENEC CB,CE,SAA,C-tick,Nemko,ROHS
(All the certificate is belong to Shenzhen Hengyao Lighting Technology,.Co.only)
9. Other Requirements
9.2 Emergency application applicable foremergency equipment
9.3 Switch Suitable for induction switch lighting device
Model name: