Product Description
Accuracy:
Liquid: ±1.0% of reading
Gas: ±1.0% of reading
Vapor Steam: ±1.5% of reading
Materials:
Housing: Standard - 304 Stainless Steel
Shedder Bar: 1Cr18Ni9Ti
Converter housing and case cover: Aluminum Alloy
Output Signal: (Where applicable)
Sensor: Pulse signal (Low Level: ≤1V; High Level: ≥6V)
Transmitter: 4 to 20 mA DC current signal
Signal Transmission Distance: ≤500 m
Electrical Connections: ISO M20×1.5 Female
Explosion Proof Level:
Standard: ExdIIBT6
Protection Level: IP65
Vibration: ≤1.0 g
Ambient:
Temperature: -10℃ to +55℃
Pressure: 86 to 106 KPa
Relative Humidity: 5% to 90%
Power Supply:
Sensor: +12V DC (Optional: +24V DC)
Transmitter: +24V DC
Field Display Type: Integral 3.2V Lithium Battery or +24V DC
Fluid Temperature and Pressure:
Temperature: Standard: -20℃ to +70℃
Optional: -20℃ to +250℃; -20℃ to +350℃
Pressure: Fluid pressure should be limited according to flange rating.
Product Image
Send Inquiry to this Member
Related Products of this Company
This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please
click here.