Model: | Neurocare-FM-70 |
---|---|
Brand: | Neurocare |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Other Electronic Instrument |
Label: | maternal monitor , doppler detector , fetal monitor |
Price: |
US $900
/ pc
|
Min. Order: | 1 pc |
Live Chat: | Last Online:23 Nov, 2013 |
Neurocare-FM-700 is a high-tech fetal & maternal monitor. It offers a reliable, high-performance solution for fetal monitoring needs in the clinic and hospital, from pre-natal check-ups to antepartum monitoring of high-risk pregnancies. PFM-700 Series is your best partner from Antepartum through Intrapartum till Delivery.
Features
l Unique notebook design, better protection to the screen and easier to carry
l 10.4 inch TFT LCD high-brightness display (1024*768), folding up from 0-135 degree
l Four working interface, big font display
l 12-crystal pulse doppler ultrasound probe contributes a better monitoring performance, with water-proof probe as optional
l Automatic and manual fetal movement detection
l Outstanding heart rate offset mode for twin monitoring, more convenient to observe
l Heartbeat overlapping detection and alarming system
l Event marker makes it easy to annotate the fetal movement status or other event on the chart
l 24 hours waveform and data storage
l Built-in rechargeable lithium battery can last up to 2 hours
l Support wired or wireless central monitoring system
Specification
Operation environment |
Power requirements AC100-240CV |
|
Power 50VA |
||
Performance Specifications |
Display 10.4inch(1024*768pixel)color TFT-LCD |
|
Indicator visual on-display and integrated, alarm light ,audible alarm |
||
Battery internal rechargeable Li-ion battery power |
||
Alarm visual on-display and integrated, alarm light ,audible alarm |
||
Memory 24-hours memory for fetal traces |
||
Printer American standard/international standard, paper Width 110mm;1/2/3cm/min real-time printing speed paper Z-fold, thermosensitive Record message ID, name, age, date, time, print speed etc |
||
CMS Wired/wireless connection to central monitoring system. Up to 64 units. |
||
Ultrasound(FHR) |
Measurement range US |
30 to 240 bmp |
Resolution display printer |
1bmp 1bmp |
|
jitter@200bmp |
≤3bmp |
|
Display update rate |
0.25second |
|
Beat to bea change(max ) for ultrasound |
28bmp |
|
US frequency |
1MHZ±5%HZ |
|
TOCO |
Measurement Method |
Strain gauge sensor element |
sensitivity |
1unit=25g |
|
Resolution |
1unit |
|
Measurement range |
500units |
|
Baseline setting |
0,5,10,15 can be selective |
|
Update rate |
0.25units |
|
Auto offset correction |
3 second after connecting transducer |
|
Auto zero adjust |
TOCO value is set to zero negative following measure value for 5 seconds negative |
|
Auto Fetal Movement(AFM) |
technique |
Pulsed Doppler ultrasound |
range |
0-100% |
|
Resolution |
1% |
|
Automatic fetal movement actograph |
||
Manual fetal movement marker |
||
Maternal NIBP (MNIBP) |
Operation mode |
Manual/automatic/STAT |
Measurement unit |
mmHg/ka selectable |
|
Test interval |
0-480 minutes |
|
accuracy |
Max, std deviation:8mmHg, max.mean error. ±5mmHg |
|
Measurement range |
Systolic 30 t0 270mmHg:diastolic:10 to 245mmHg:Mean: 20 to 255mmHg |
|
Pulse rate range |
20-250bmp |
|
Over-pressure protection |
Yes |
|
Maternal Spo2 (MSpo2) |
Measurement range |
0%-100% |
Resolution |
1% |
|
Pulse rate range accuracy |
±3% |
Configuration
Standard Configuration
1.FHR, TOCO, FM
2.Twins FHR, TOCO, FM
3.FHR, TOCO, FM, SPO2, NIBP
4.Twins FHR, TOCO, FM, SPO2, NIBP
Optional Configuration
1.Waterproof ultrasound probe
2.Wired/wireless central monitoring system
3.Fetal acoustic stimulator
4.Trolley / wall mounting / carrying bag