Product Description

CE Approved ICU Patient Monitor ECG NIBP SPO2 Resp TEMP 

Features

■ Color TFT Screen, waveform  up to 8 channels

■ Light and portable with build-in rechargeable battery

■ UP to 10 kinds of monitor parameters

■ Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis

■ 72 hour storage and review of trend grams and tables, 40 second review of olographic  wavefo rms.

■ Built-in recorder(option)

■ All-round monitor of adult ,pediatric and neonatal.

■ Electrosurgical unit and defibrillation protected

■ Standard parameters: ECG, NIBP, SPO2,  Respiration,  Temperature, Pulse rate

 

■ Option parameters: EtCO2, CO, IBP,  Thermal Printer   


ECG

 

■ 5-lead or 3-lead selectable

■ Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C

■ Lead selection: I; II; III; avR; avL; avF; Vx; CAL

■ Gain selection: 12.5mm/s, 25mm/s, 50mm/s

■ Accuracy: ±1bpm or ±1%, whichever is greater

■ Protection: Withstand 4000VAC/50Hz voltage in  isolation against electrosurgical and defibrillation

■ Calibration signal: 1mV±5%

■ Operation modes: Diagnostic, Monitor, Surgery

■ Alarm range: Adult: 15-300bpm

■ Pediatric/Neonatal: 15-350bpm

■ Alarm range: -2.0mV~2.0mV

■ S-T detection: YES, Arrhythmia analysis: YES

■ Alarm: YES, audible and visual alarm, alarm events recallable

NIBP

■ Method: Oscillometry

■ Operation modes: Manual/Automatic/STAT

■ Measurement unit: mmHg/KPa selectable

■ Measurement types: Systolic, Diastolic, Mean

■ Measurement range: Adult: 10-270mmHg

■ Over-pressure protection: YES

■ Resolution: 1mmHg

■ Accuracy: Mean error and standard deviation   per ANSI/AAMI SP-10

■ Alarm: Systolic,Diastolic,Mean

SpO2

■ Measurement range: 0-100%

■ Accuracy: ±2digit (70~100%);

■ 0~69% unspecified

■ Alarm range: 0-100%

Respiration

■ Method: RA-LL impedance

■ Pediatric/Neonatal: 6-150rpm

■ Alarm range: Adult: 6-120rpm

■ Pediatric/Neonatal: 6-150rpm

■ Apnea alarm: YES

Temperature

■ Resolution: 0.1℃

■ Channel: Dual-channel

■ Alarm range: 0-50℃

 

EtCO2

■ Measurement Mode: Side-stream or mainstream

■ Measurement range: EtCO2: 0-99mmHg

■ Accuracy: CO2 concentration

■ Apnea alarm: YES

 

Option:

CO

■ Method: Thermo-dilution

■ Measurement range: CO: 0.1-20 lit./min.

IBP

■ Channel: 2 channels

■ Pressure transducer: Sensitivity: 5( mV/V/mmHg)

■ Transducer sites: ART, PA, CVP, RAP, LAP, ICP

■ Alarm range: -10~300mmHg


Product Image

 CE approved 12.1 Patient Monitor color display (MK9000) 1
Img 1

Send Inquiry to this Member

Makcom Medical Electronics Co ,.ltd

Hebei Avenue 114, Haigang Zone , Qin huangdao, Heibei, China

Phone:
86-0335-7788304
Fax:
86-0335-7788588
Contact:
Serena (Sales Manager )
Mobile:
13303354359

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Other Electrical & Electronic Made In China Products

,  

Other Electrical & Electronic China Suppliers and China Manufacturers