Product Description
Features:
- Single or Twins Ultrasound transducer
- Data Graph and Trend Table Review of both mother and fetal
- Built-in thermal printer
- Built-in Network capability for connect with central monitoring software
- Programmable alarms
- All the colors and looks or the parameters can be customsized
- Multi-face views, select focus on mother or fetal
- Storage of patient information and data
Performance Specifications:
- Display:8.4" Color TFT
- Resolution:640x480
- Display Mode:Standard View,Fetal View,Mother View
- Indicator:Power indicator light, Alarm sound
- Interface:Socket for connecting fetals FHR, TOCO, and Fetal Movement sensorSocket for connecting mothers ECG, NIBP and SPO2 sensor.Net Socket(RJ45) for communication cable with Central Monitoring Station Sofrware.
- Power Supply:AC 100 ~ 240V, 50/60Hz, Powe < 60VA
- Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours.
- Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 items.
- Alarm:Ajustable High and Low limits. Three level audible and vistual alarm.
- User Configuration:All the color of parameters and waves can be set according to users willing.
Technical specifications:
- Safety
- Meet the requirment of IEC60601 series
- Type of Protection:Class II with internal electirc power supply
- Degree of Protection:BF
- Dimention and Weight
- Dimention:92(W)x82(H)x22(D)mm
- Weight:136g(with battery)
- Operation Environment:
- Temperature:0℃~ +40℃
- Humidity:15% ~ 95%
- Storage Environment:
- Temperature:-20℃~ +60℃
- Humidity:10% ~ 95%
- Patient Range:Pregnant Adult
FHR:
- Ultrasound Frequency:2MHz
- Range:50 ~ 210 bpm
- Resolution:1bmp
- Accuracy:±2bmp
TOCO:
- Range:0 ~ 100%
- Resolution:1%
- Non-linear Error:<=±8%
- Zero control:Manual
FETAL MOVEMENT:
- Manual fetal movement mark
SPO2:
- Measurement Range:0 ~ 100%
- Resolution:1%
- Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion)
- ±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified
- Alarm Range:0% ~ 100%
- Refreshing Rate:1s
Pulse Rate:
- Measurement Range:25 ~ 250 bpm
- Resolution:1bpm
- Accuracy:±3 bpm (non-motion)
- Alarm Range:25 ~ 250 bmp
- Refreshing Rate:1s
ECG:
- Lead mode:3-lead or 5-lead
- Lead selection:I, II, III, AVR, AVL, AVF, V
- HR range:15 ~ 300 bpm
- ECG Waveform:2 channals
- Accuracy:±2bpm or ±2%, which is greater
- S-T segment detection range: -2.0mv ~ +2.0mv
- Arrhythmia analysis: 13 kinds of arrhythmia
- Alarm Range:15 ~ 300 bpm
NIBP:
- Method:Oscillometry
- Mode:Manual/Auto/Contiuous
- Measurement Range:25 ~ 260mmHg
- Atuo Measure Interval: 5, 10, 15, 30, 45, 60, 90 minutes
- Resolution:1mmHg
- Overpressure Protection: 300mmHg
- Alarm range:25 ~260mmHg