When a common misunderstanding. Here is a manufacturing engineering department of the Suzhou Huasheng fan, anti-corrosion fan who buy the majority of FRP fan optional formula, for reference only.
Fan motor horsepower formula
HP = Pt × Q ÷ 6120 ÷ 0.746 ÷ 0.6
Among them, the .746 is power KW converted to horsepower HP's conversion factor, 0.6 is the efficiency of the fan.
Selected instance
Example:
28000 CMH = 466 CMM
2600 Pa = 260 mmAq
Apply the formula can be drawn:
HP = 260 × 466 ÷ 6120 ÷ 0.746 ÷ 0.6
= 44.2 should be used 50 hp
Example:
33500 CMH = 558 CMM
2600 Pa = 260 mmAq
Apply the formula can be drawn
HP = 260 × 558 ÷ 6120 ÷ 0.746 ÷ 0.6
= 52.9 the selection of 60 hp
Three examples:
47000 CMH = 783 CMM
3000 Pa = 300 mmAq
Apply the formula can be drawn
HP = 300 × 783 ÷ 6120 ÷ 0.746 ÷ 0.6
= 85.7 should be used in the 100 hp
If you have any fan questions or if you have special needs, please feel free to contact us!
Product Image
Img 1
Img 2
Img 3
Img 4
Img 5
Send Inquiry to this Member
Related Products of this Company
This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please
click here.
China Suppliers Quick Searching:
,