CUMMINS 100kw Diesel Generator Set for landuse
Product Description
Model EGL100D
Continous output(50Hz) 100KW/125KVA
Standby output(50Hz) 110KW/138KVA
Rated frequency(Hz) 50/60
DIESEL ENGINE
Engine model DCEC Cummins 6BTAA5.9-G2
No. of cylinders 6(in-line)
Displacement(L) 5.9
Induction system Exhaust turbocharged, air-air inter-cooling
Combustion system PN type fuel pump
Bore*Stroke(mm) 102*120
Compression ratio 17.5:1
Rated speed(rpm) 1500
Maximum power(KW/HP) 130/176
speed control system High precision elelectrical speed governor
Exhaust system exhaust smoke level(m3/min) 19.44
Exhaust temperature(°C) 495
Maxium exhaust back pressure(kPa) 10
Induction system Maxium intake pressure(kPa) 6.35
Air consumption(m3/min) 8.7
Air flow(m3/min) 190
Fuel system 100% load fuel consumption(L/H) 33
Lubrication system The total capacity of oil(L) 16.4
Oil consumption(g/kwh) ≤4
Oil sump capacity(L) 14.2
Rated oil pressure(kPa) 345
Cooling system Coolant capacity
(engine and radiator)(L) 16
Thermostat opening temperature(°C) 82-95
Maximum water temperature(°C) 104
ALTERNATOR
Alternator model(Stamford) UCI274E
Alternator model(Marathon) MP-104-4
Alternator model(Engga) EG225-100N
Phase 3
Winding connection 4 wire 3 phase ,Y type
Starter battery capacity(Ah) 165*2
Starter battery voltage(V) 24
No. of bearings 1
Power factor 0.8
Protection class IP23
Altitude requirement(m) ≤1000
Excitation mothod Brushless
Insulation class /temperature class H/H
Steady-state voltage reguation ≤±1%
Alternator capacity 140KVA
Alternator efficiency 91.70%
Cooling air flow(m3/s) 0.514
UNIT SPECIFICATION
voltage regulate range ≥±5%
Steady-state voltage reguation ≤±1%
Transient voltage deviation(100% sudden power reduction) ≤+25%
Transient voltage deviation(sudden power incremen) ≤-20%
Voltage stabilization time (100% sudden power reduction)(S) ≤6
Voltage stabilization time (sudden power increment) (S) ≤6
Steady-state frequency regulation 0-5% adjustable
Frequency volatility ≤0.8%
Transient frequency deviation (100% sudden power reduction) ≤+12%
Transient frequency deviation (sudden power increment) ≤-10%
Frequency recovery time(100% sudden power reduction)(S) ≤5
Frequency recovery time (sudden power increment)(S) ≤5
Size
Open type external dimension of base fuel tank(mm) 2400*870*1600
Net weight(kg) 1700
Slient type Silent type external dimension(mm) 3230*1170*1800
Weight(kg) 2300