| Model: |
2316PLUS |
| Brand: |
HONEYWELL |
|
|
| Details Information : |
|
Number of Zones
Sixteen fully programmable hardwired zones,
including a 2 wire powered zone for smoke
detectors; plus 3 keypad-activated panic soft
zones.
Zone Types
Entry/Exit, Entry/Exit with double Delay time,
Alarm, Alarm with walkthrough, 24-Hours; with
options by zone for Chime, Delay Before Dial,
Shunt, Restoral and Day annunciation.
Signal Reporting
By zone: Alarm, Isolate, Trouble, Restore.
By user : Cancel, Openings, Closings, Duress.
Unit status : AC Failure, Low Battery, Failure To
Communicate, Watchdog Reset, Completed
Programming, Bell Fuse Fail.
Zone Timing
Entry delay programmable from 10-300 sec.
Exit delay programmable from 10-150 sec.
User Codes
Thirty-two 2-digit to 5-digit user codes with
independent authority levels; programmable by
master code (User #1); opening/closings by
User ID.
Engineer Access Code
6-digit code required for all programming;
cannot be used to set or unset the system.
Timed Guest Combination
User #8 code can be used as timed guest
combination; valid for up to 15 consecutive
days.
Unique Call-Back Process
Programmable call-back scheme prevents
unauthorised access; also allows SYS 2316 to
bypass most call-waiting and answering
machines.
Pirate-Guard?/DIV>
When programmed, SYS 2316 will not revert to
default engineer access code at power loss.
Cabinet Dimensions
Zinc-plated CRS 0.8 mm steel; accommodates
optional wall and cover tamper switches
313x268x79 mm (HxWxD)
Weight : 3.2 kg
Circuit Type
NO/NC; EOL; supervised with timed siren; or
supervised with latched siren.
Power Input
16.5 Vac, 25 VA.
Standby Battery
12 V, 7.0 Ah sealed-acid battery.
External Siren Output
10.5 ~ 13.5 Vdc @ 750 mA.
Total Auxiliary Power
500 mA, regulated.
Digital Communicator
Three 18-digit phone numbers; two for
Event/Status Reporting; one for Remote
Programming (RPS); Pulse or Touch Tone?/DIV>
dialing option.
Reporting
Dual, split or back-up.
Receiver Formats
- Fast ?2300 Hz;
- Slow ?1400 Hz;
- SumCheck 1400 Hz;
- SumCheck 2300 Hz;
- Ademco DTMF 1400 Hz; CFSK III.
Message Formats
3/1 Extended, 4/2, CFSK III, SumCheck, 4+2
Ademco.
Approvals
Information on approvals, to be requested from
|
|
click for larger image