36W Open Frame Power Supply
Product Description
·Universal AC input/Full range |
·No load power consumption <0.5W |
·Meet energy star level IV(CEC) |
·Protection: overload/short circuit |
Model |
BNF365050 |
BNF367540 |
BNF369040 |
BNF361230 |
BNF361524 |
BNF361820 |
BNF362415 |
BNF363610 |
Output |
DC voltage |
5.0V |
7.5V |
9.0V |
12.0V |
15.0V |
18.0V |
24.0V |
36.0V |
Rated current |
5.0A |
4.0A |
4.0A |
3.0A |
2.4A |
2.0A |
1.5A |
1.0A |
Current range |
0~5.0A |
0~4.0A |
0~4.0A |
0~3.0A |
0~2.4A |
0~2.0A |
0~1.5A |
0~1.0A |
Rated power |
25W |
30W |
36W |
36W |
36W |
36W |
36W |
36W |
Ripple & Noise |
50mVp-p |
75mVp-p |
90mVp-p |
120mVp-p |
150mVp-p |
180mVp-p |
240mVp-p |
360mVp-p |
Voltage tolerance |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
Line regulation |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
Load regulation |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
Input |
Voltage range |
90~264Vac, 135~370Vdc |
Frequency range |
47~63Hz |
Efficiency |
>70% |
>70% |
>75% |
>80% |
>80% |
>80% |
>80% |
>80% |
Inrush current (max.) |
Cold start 30A/230Vac |
Leakage current(max.) |
<0.25mA/240Vac |
Protection |
Over load |
>110% rate output voltage power for 5.0V~36V |
Protection type:auto-recovery after fault condition is removed |
Short Circuit |
power shutdown |
Protection type:auto-recovery after fault condition is removed |
Environment |
Working Temp. |
-20~+40℃ |
Working Humidity |
20%~90% RH non-condensing |
Storage Temp. Humidity |
-20℃~85℃, 10%~95% RH |
Temp. Coefficient |
±0.05%/℃ (0~50℃) |
Vibration |
10~500Hz, 2G 10min/ cycle,period for 60 min,each along X,Y,Z axes |
Safety & EMC |
Safety Standard |
UL60950-1, EN60950-1 |
Withstand voltage |
I/P-O/P:3KVac, I/P-FG:1.5KVac,O/P-FG:0.5KVac |
Isolation resistance |
I/P-O/P, I/P-FG,O/P-FG: 100M ohms/500Vdc |
EMI condition & radiation |
Compliance to EN55022 class B, FCC part15 class B |
Harmonic current |
Compliance to EN6100-3-2,3 |
EMS immunity |
Compliance to EN6100-4-2 |
Other |
Dimension |
98mm*39mm*23.5mm |
Packing |
-------- |
Note |
1.Al l parameters are specified at 230Vac input, rated load,25℃ 70% RH ambient; |
2.Ripple & Niose are measured at 20Mhz of bandwidth by using a 30mm twisted-pair wire terminated with a 0.1uf & 47uf parallel capacitor |
3.Tolerance: includes set up tolerance, line regulation, load regulation, |
4.Line regulation is measured from low line to high line at rated load, |
5.Load regulation is measured from 0%~100% at rated load |
6.The power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed that is |
still meets EMC derectives |