Winner 2008 wet laser particle size analyzer

Model:Winner 2008 A/B
Brand:Winner
Origin:Made In China
Category:Industrial Supplies / Other Industrial Supplies
Label:particle analyzer
Price: US $11598 / pc
Min. Order:1 pc
Inquire Now Add to Basket

Member Information

Detail

Jinan Winner Particle Instrument Stock Co., Ltd.

Free MemberShan Dong - China
Live Chat:Last Online:13 Oct, 2023

Product Description

 

Product Description

Winner2008A full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01μm to 2000μm, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.

 

Main Features

(1)Winner Patent -Optical path design
Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Double spectrum design make its precision achieves from 0.01um to 1200μm,and Dual-laser orthogonal light make use of the semiconductor auxiliary laser extend the test angle from 45 degree to 135 degree, ensure receive all the angles of signals.

(2) Expand Size Range
measurement range significantly expanded to 0.01um, particularly suitable for small samples of the user, the sub micron particle test results reached the international level

(3)Full built-in dispersion system
The ultrasonic dispersion, mechanical stirring and circulation channel reasonable integrated in the interior of the instruments, ensure the uniform dispersion and distribution of particles in the testing process, effectively avoid uneven distribution, large particle deposition phenomenon caused by long pipe line of outside dispersion system , to ensure the accuracy of the test results.

(4)Intelligent Operation mode
With intelligent automatic mode of operation, to achieve a key test, as long as according to the prompt addition of sample, click the "test", all processes including water-supply, dispersion, circulation, testing, cleaning, data record, data analysis, save and print are automatically completed, not only reduce the testing workload, but also eliminate the interference of human factors, to further improve the accuracy and authenticity of testing results.

(5)Automatic Optical path alignment system

The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.1um, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.


(6)Authoritative calibration method
In the entire test range using the national standard materials for calibration, only a year calibration once the instrument can. Calibration method is simple and quick.

(7) Unconstrained free fitting technique

Winner original unconstrained free fitting technology, particle size analysis is not affected by any functional constraints, can be a true reflection of the distribution of particles.

 

Specification

Model Name

Winner2008A

Winner2008B

Standard

ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009

Principle

MIE scattering principle

Measuring Range

0.01μm-2000μm

0.01μm-1200μm

Channels Number

127

120(different photo detectors & optical light path)

Accuracy error

≤0.5% (Deviation of D50 on national standard sample)

Repeatability error

≤0.5% (Deviation of D50 on national standard sample )

Light source

High performance He-Ne Laser (λ= 632.8nm, P>2MW)
Lifetime>25000hours


Dispersion
Method

Ultrasonic

Frequency:40KHz Power:35W, Time: ≥1S ,Anti-dry function

Stir

Revolutions Speed: 0-3000RPM (Adjustable)

Circulate

Rated Flow:8L/min Rated Power:10W

Sample Pool

Volume:350mL

Micro-
Sample Pool

Volume: 10mL ( Available)

Operation Mode

Full automatic/ manual control, freely choose

Resolution

Free distribution truly reflect particle size distribution

Optical bench alignment system

Japan Canon lens, Full automatic,precision is up to 0.1um

Software function

Analysis mode

Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.

Statistic Method

Volume Distribution, Quantity Distribution

Statistic Comparison

Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.

User-defined Analysis

Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries

Test Report

Word, Excel,Photo( Bmp), Text etc

Multiple-language Support

Multiple language Support

Intelligent operation

Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor

Testing speed

<2min/time

Outer dimension

L104cm*W44cm*H54cm

Net weight

58Kg

 

 

Principle

Test Operation Interface

Demo Test Report

Quality Assurance

1. Strictly conforming to ISO9001-2000 quality management system.2. Strict control from purchasing materials, process inspection to final particle size distribution test.

3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected completely before sale.
5.Laser particle size analyzer will be processed preventing -shake test before delivery.

 

After Sale Service

1.Operation demo video CD will be offered.

2. Offer free-training service.

3. The quality assurance date is 1 year since finishing payment, Technology support will be provided for life. And after that, we will collect the cost if provide repair accessories.

4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).

5. We offer the components with favorable price and perdurable maintenance.


Product Image

Winner 2008 wet laser particle size analyzer 1
Img 1
Winner 2008 wet laser particle size analyzer 2
Img 2
Winner 2008 wet laser particle size analyzer 3
Img 3
Winner 2008 wet laser particle size analyzer 4
Img 4
Winner 2008 wet laser particle size analyzer 5
Img 5

Send Inquiry to this Member

Jinan Winner Particle Instrument Stock Co., Ltd.

Unit 2, East, Building F, North District, University Science and Technology Park, No. 750 Shunhua Road, Lixia District

Phone:
+86-0531-88876213
Fax:
Contact:
Ella Ren (Foreign trade operat)
Mobile:
17362290807

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Other Industrial Supplies Made In China Products

,  

Other Industrial Supplies China Suppliers and China Manufacturers