Home > Products > Electronics & Electricity > Transducer

RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor 1RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor 2RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor 3RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor 4
  • RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor 1
  • RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor 2
  • RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor 3
  • RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor 4

RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor

Model:RS-CO-*-2
Brand:RENKE
Origin:Made In China
Category:Electronics & Electricity / Transducer
Label:carbon monoxide sens , RS485 4 to20 ma gas , RS485 4 to20 ma gas
Price: US $43.5 / pc
Min. Order:1 pc
Inquire Now Add to Basket

Member Information

Detail

Shandong Renke Control Technology Co., Ltd.

Free MemberShan Dong - China
Live Chat:Last Online:19 Aug, 2020

Product Description

RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor

Product Description

Our Carbon monoxide detector uses electrochemical technology to measure CO concentration, and the reaction is rapid and sensitive. The transmitter is widely used in air quality testing, smart home and other occasions where CO detection is required. Analog signal output, 4-20mA, 0-10V, 0-5V optional. The equipment is 10-30V wide-voltage power supply, and the enclosure has a high degree of protection, which can adapt to various harsh conditions on site.

RS485 OUTPUT

ANALOG OUTPUT

Power supply

10-30VDC

Power supply

10-30VDC

Power consumption

0.18W

Power consumption

0.18W

Measure range

0~2000ppm

Measure range

0~1000ppm

Accuracy

±10%FS

Accuracy

±10%FS

Operating temperature

-20℃~+50℃

Operating temperature

-20℃~+50℃

Operating humidity

15%RH~90%RH

Operating humidity

15%RH~90%RH

Data update time

2s

Data update time

2s

Stability

<10%

Stability

<10%

Resolution

0.1ppm

Resolution

0.5ppm

Output signal

RS485

Output signal

4~20mA/0~5V/0~10V

Details Images

■The high-sensitivity gas detection probe has stable signal and can accurately measure the PPM CO concentration with high accuracy. ■Wide measuring range, default 0-1000ppm. ■4-20mA, 0-10V, 0-5V multiple analog signal outputs are available. ■The product adopts a wall-mounted waterproof shell, which is easy to install and has a high degree of protection.

Electrical Wiring

 

Line color

Description

 

 

power

brown

Power supply(10 ~ 30V DC)

black

Power supply negative

 

Communication

yellow

485-A

blue

485-B

Range 10V-30V of wide voltage is available in power input, the A wire and B wire can not be connected contrary when connecting to 485 signal, and the address among several devices on the total wire can not be conflicted.

 

Line color

Description

 

 

power

brown

Power supply (10~30V DC)

black

Negative power supply

 

 

output

blue

Positive CO signal

green

CO signal negative

NOTE:  Two types wire methods

             

             1.Four-wire connection diagram

             

             2.Three-wire connection diagram

Calculation Method

Analog Calculation method

1.Current output signal conversion calculation 

For example, the range is 0~1000ppm, 4~20mA output, when the output signal is 12mA, the current CO concentration value is calculated. The CO range span is 1000ppm and is expressed by a 16mA current signal.
1000ppm/16mA=62.5ppm/mA, that is, the current 1mA represents a CO concentration change of 62.5ppm, and the measured value is 12mA-4mA=8mA, 8mA*62.5ppm/mA=500ppm. The current CO concentration is 500 ppm. 

2. Voltage type output signal conversion calculation
For example, the range is 0~1000ppm, 0-10V output, when the output signal is 5V, the current CO concentration value is calculated. The span of this CO range is 1000ppm, expressed by a 10V voltage signal, 1000ppm/10V=100ppm/V, that is, the voltage 1V represents a change in CO concentration of 100ppm, the measured value is 5V-0V=5V, 5V*100ppm/V=500ppm, current CO The concentration is 500ppm.
3.CO measurement unit ppm and ug/m3 conversion relationship 

At standard atmospheric pressure, the conversion is based on the following conversion formula, which is only applicable to the calculation of CO: 1ppm = 28/22.4=1.25mg/m3=1250ug/m3 1ppb =28/22.4=1.25ug/m3

 

Why choose us?

Before-sale service:

1.OEM price,delivery sensors in 3 days.
2.Offer CE, ISO, FCC, ROHS Certificats.
3.24 hours service online.
4.Welcome to visit our factory.
5.Sample is avaliable.

After-sale service:
1.2 years warranty for our sensors.
2.Offer 24 hours free technical support
3.Free cloud server

Application

Company Introduction

Shangdong Renke Control Technology Co.,Ltd. is a leading environmental monitoring high technology enterprise in China. Renke is engaged in industrial sensor, communication gateway, industrial data platform, cloud computing service,and measurement control technology solution. We have won good reputation for high quality products and sincere service.Renke insists on the policy that"technology first, exquisite design, customer satisfied" we are careful with every detail. Every drawing has to be considered and revised repeatedly. Every products is the thought of designer.

FAQ

Q: Are you manufacturer?
A: Yes, We are Tranmitter manufacturer and exporter in china over 10 years experience with CE, ROHS, FCC, ISO and 11patents.
RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor
Q: Do you offer the OEM service?
A: Yes, we can offer OEM service and design the shell and logo for you.

Q: Do you offer free samples?
A: Sorry , we do not offer free samples. After you bulk order, we will deduct the sample fee from second order.
RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor
Q: What payment ways do you accept?
A: You can pay us by T/T , PayPal , and West Union .
RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor
Q: What is your delivery time?
A: It is in 3-5 working days since the payment confirmed. If your order is over 3000pcs, we need 10 days.
RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor
Q: How is your quality assurance service?
A: 24 months quality guarantee.
RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor
Q: Could we make a visit to your factory?
A: Yes, you are welcomed .


Product Image

RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor 1
Img 1
RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor 2
Img 2
RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor 3
Img 3
RS485 4 to20 ma gas detector co sensor 0-10v carbon monoxide sensor 4
Img 4

Send Inquiry to this Member

Shandong Renke Control Technology Co., Ltd.

Shun Tai Plaza, High - tech Development Zone, Licheng District, Jinan, Shandong

Phone:
86-0531-15628902298
Fax:
Contact:
helen (Sales Manager)
Mobile:
15628902298

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Transducer Made In China Products

,  

Transducer China Suppliers and China Manufacturers