Home > Products > Industrial Supplies > Industrial Supplies Stocks

Suncenter gas booster system for industrial gas cylinder transfer and filling 1
  • Suncenter gas booster system for industrial gas cylinder transfer and filling 1

Suncenter gas booster system for industrial gas cylinder transfer and filling

Model:DGA series
Brand:SUNCENTER
Origin:Made In China
Category:Industrial Supplies / Industrial Supplies Stocks
Label:gas booster system , Air driven compress
Price: US $1000 / pc
Min. Order:1 pc
Inquire Now Add to Basket

Member Information

Detail

SUNCENTER FLUID CONTROL EQUIPMENT CO.,LTD

Free MemberGuang Dong - China
Live Chat:Last Online:05 Jun, 2018

Product Description

Product Details

Suncenter Gas Booster System For Industrial Gas Cylinder Transfer And Filling

Pneumatic (Air compressor driven) gas booster system

图片37.jpg

 

Suncenter - Gas booster system are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet. 

To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. 

The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. 

Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor). 

Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option. 

 

Applications

·Pressure test with gas

·Gas transfer and filling

(Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)

·Charging of gas cylinder and accumulator with nitrogen

·Supply for isolating gas systems

·Gas assisted injection molding

·Transfer of oxygen cylinders

·Charging of breathing air bottles

·Leak test 

·Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components

·Safety valve adjusting

 

Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System

gas booster

gas booster manufacturer

gas booster system

nitrogen booster pump

nitrogen gas booster

nitrogen gas booster system

oxygen gas booster


 

图片38.jpg

 

DGS booster system = booster pump+ following valves, gages, and parts

 

The hottest selling- model A and model C cabinet picture

图片40.jpg图片41.jpg

 

The standard gas booster pumps system including following parts:

Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

Stainless steel (carbon steel) material cabinet (Three models for choosing)

F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

Driven air switch (Pump starting switch), driven air pressure gauge

Gas inlet switch, Gas inlet pressure gauge

Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

And we could also customize it according to clients’ special requirement.

 

Technical specification for DGS-DGA series

 

Model

Pressure 

boost ratio

Min. gas 
Inlet 

pressure 
PA (bar)

Max.gas 
Inlet 

pressure 
PA (bar)

Max. gas 
outlet pressure 

PB (bar)

 

Driven air pressure  PL

Formula to 
calculate gas outlet pressure PB

Connection: 
Gas Inlet / 
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

3-8 bar

2XPL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

1.5 

40

40

3-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

3-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0 

200

200

3-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

3-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20 

480

480

3-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

3-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

3-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )

Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  

In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar

 

 

 

Technical specification for DGS-DGD series

Model

Pressure 

boost ratio

Min. gas 
Inlet 

pressure 
 PA (bar)

Max.gas 
Inlet 

pressure 
PA (bar)

Max. gas 
outlet pressure 

PB (bar)

 

Driven air pressure  PL

Formula to 
calculate gas outlet pressure PB

Connection: 
Gas Inlet / 
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

3-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

3-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

3-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

3-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

3-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  

In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar

 

 


Technical specification for DGS-DGT series

Model

Pressure 

boost ratio

Min. gas 
Inlet 

pressure 
 PA (bar)

Max.gas 
Inlet 

pressure 
PA (bar)

Max. gas 
outlet pressure 

PB (bar)

 

Driven air pressure  PL

Formula to 
calculate gas outlet pressure PB

Connection: 
Gas Inlet / 
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

1

10

200

3-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

1

10

320

 

3-8 bar

40XPL+ 6XPA

 

1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

1

10

480

3-8 bar

60XPL+6X PA

 

1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

 

3-8 bar

60XPL+2.5XPA

 

1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

1

10

800

3-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )

 

Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  

In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar

Should the gas booster system caters to your requirement, welcome to buy the equipment with our factory. Well-known as one of the professional manufacturers and suppliers, we're equipped with a productive factory to produce the best quality equipment for you.

gas booster,gas booster manufacturer,gas booster system,nitrogen booster pump,nitrogen gas booster

nitrogen gas booster system,oxygen gas booster


Product Image

Suncenter gas booster system for industrial gas cylinder transfer and filling 1
Img 1

Send Inquiry to this Member

SUNCENTER FLUID CONTROL EQUIPMENT CO.,LTD

NO.285,Guantai Road, Yuanwubian, Nancheng District, Dongguan city, Guangdong province, China

Phone:
0769-35219490
Fax:
Contact:
Rose Zhang (overseas sales)
Mobile:
15812870862

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Industrial Supplies Stocks Made In China Products

,  

Industrial Supplies Stocks China Suppliers and China Manufacturers