GD-510D ASTM D2500 Cloud Point Analyzer&ASTM D97 Pour Point Analyzer
Packaging & Delivery
Packaging Details | Standard wooden case for GD-510D ASTM D2500 Cloud Point Analyzer&ASTM D97 Pour Point Analyzer |
---|---|
Delivery Time | 7 business days |
Introduction:
» GD-510D Pour Point&Cloud Point Tester is designed and made as per national standards of People's Republic of China GB/T3535 Test Method for Pour Point of Petroleum Oils and GB/T6986 Test Method for Cloud Point of Petroleum Oils.
» GD-510D Pour Point&Cloud Point Tester is suitable to determine pour point and cloud point of petroleum oils.
I. Main Technical Features
» The working table is made of stainless steel material. It has two cold chambers(chamber I and chamber II) .Each chamber is equipped with two baths.The temperature of two baths are equal. All the baths can do determination for pour point and cloud point.
» It is no need to use coolant in the trough. The cooling speed is fast and cooling efficiency is high. The temperature controller I controls the temperature of chamber I and temperature controller II controls the temperature of chamer II. The minimum temperature of chamber II can reach -70℃ and temperature control accuracy can reach ±1℃.
» The instrument adopts desktop structure, concise design and easy to use.
II. Main Technical Specs
1 |
Power supply |
AC 220 V±10%, 50 Hz; |
2 |
Temperature control range of cold chambers |
Cold chamber I: room temperature~-51 ℃, ±1 ℃, the temperatures of two baths are equal. |
Cold chamber II: room temperature~-70 ℃, ±1 ℃, the temperatures of two baths are equal. |
||
3 |
Refrigeration system |
a refrigeration compressor of new type |
4 |
Ambient temperature |
≤30 ℃ |
5 |
Relative humidity |
≤85% |
6 |
Maximum power consumption |
1500 W |
7 |
Dimension |
800mm×580mm×400mm |
III. GD-510 Series Low Temperature Flowability Tester
Model |
GD-510 |
GD-510G |
GD-510G-II |
GD-510E |
GD-510D |
GD-510F1 |
Purpose |
Solidifying point |
Solidifying point |
Solidifying point |
Solidifying point, Cold filter pl ing point |
Pour point, Cloud point |
Solidifying point, Pour point, Cloud point, Cold filter pl ing point |
Full scale |
ambient~-50℃(Room temperature) |
ambient~-70℃(Room temperature) |
-20℃~+80℃ |
ambient~-70℃(Room temperature) |
ambient~-70℃(Room temperature) |
ambient~-80℃(Room temperature) |
Temperature controlling accuracy |
±1℃ |
±0.5℃ |
±0.5℃ |
±1℃ |
±1℃ |
±0.5℃ |
Structure |
Single trough two baths |
Single trough two baths |
Single trough two baths |
Two trough four baths |
Two trough four baths |
Four trough eight baths |
Refrigeration |
semiconductor |
compressor |
compressor |
compressor |
compressor |
compressor |