SNV-308 Overhead Line Earth And Short-circuit Fault Indicator

Model:SNV-308
Brand:SNOVA
Origin:Made In China
Category:Electronics & Electricity / Power Supply & Distribution / Power Distribution Cabinet
Label:Overhead Indicator , Fault Indicator , Cable Faults
Price: US $1 / pc
Min. Order:100 pc
Inquire Now Add to Basket

Member Information

Detail

Zhuhai SNOVA Electric Technolagy(HongKong)CO.,LTD

Free MemberGuang Dong - China
Live Chat:
点击这里给我发消息Last Online:22 May, 2024

Product Description

Overhead Line Short Circuit and Earth Fault Indicator ( SNV-308 )

 

Specifications

SNV fault indicators can quickly and easily indicate fault and identify fault locations, used in cable and overhead power lines.www.snovatech.com or www.snovaglobal.com.

 

Function and Benefit

  • Indicate the fault line and fault point quickly, lessen the blackout area;
  • Shorten troubleshooting time,improving electricity and power supply reliability;
  • Accurately indicate the instant fault, which is conducive to rule out the power supply problems;
  • Providing technical means for find the hidden permanent fault point;
  • Shorten the search time to find the fault point, reduce the labor intensity of line patrol person;
  • Defining the responsibility of the fault area and responsible people;
  • Avoiding traditional multiple switch out,switch on,line patrol to the effects of power equipment.

 

Technical Parameters

  • Applicable voltage grade: U≥6-35KV
  • Applicable wire current: I≤1200A
  • Applicable wire diameter: 16mm sq≤D≤240mm sq
  • Action response time: 0.06s≤t≤3s
  • Reset time: 6,12,24,48H (Selectable, Default 24H)
  • Ambient temperature: -35℃≤T≤+70℃
  • Operation times: ≥5000Times
  • Static power loss: ≤10μW

Action principle
Short circuit detection principle: According to the phenomenon of short circuit,the current break when
Short circuit happen, the action on the basis of the protection movement power outages.


Used to judge the short circuit fault indicator diagram:

As line 2# B phase 2,5,8 indicator and line 2# C phase 3,6,9 indicator turn red, but the 11,12 indicator still
Show white, that judged the point D happen short circuit

 

Used to judge the grounding fault indicator diagram:


as line 2# C phase 3,6,9 indicator turn red,but the 12 indicator still show white, that judged the point D
Happen grounding fault.


the experimental technical requirements:

  • In normal line steady current running after more than 20 seconds then mutation 1 second current back to
  • Zero that the indicator show alarm indication.
  • Indicator alarm reset in a steady line current is greater than 20A,it will automatic reset within 20 seconds;
  • When the line current is less than 20A, the indicator will automatic reset within 48H.
  • Running time: ≥20S                                    the action response time: ≤1S
  • Mutation current: ≥150A                               Reset time: 6,12,24,48H (Selectable, Default 24H)
  • Automatic reset current and response time: ≥20A,20S

If you are interested in our products ,please contact with us .

Contact:Andrew Mao

Email:@163.com or 626387134@qq.com

Mobile:0086-13570657698

Wechat :13570657698  QQ:626387134

Hot Sales of SNV308 Overhead Type Earthing and Short Circuit Fault Indicator Four Remote Type

Characteristic:

  • Support for the judgement of the coincidence gate 
  • Accurate synthesis of zero sequence current
  • Intelligent motor control card
  • Ultra low power consumptinon in real time sampling
  • A wave of 64 point difference sampling
  • Support remote serve upgrade and parameter settings
  • Accurate judgement of the grounding fault by the change of zero sequence current
  • Time synchronization between the sensor and the sensor
  • Optional threshold,incremental,percentage of multiple fault judgement
  • Calibration of each sensor is carried out to ensure consistency of sampling
  • The accurancy of the current sampling is less than 10A ±0.3A,10-2000A ± 2%
  • Temperature sampling precision  ± 0.5℃,Voltage precision of ground electric filed ± 10%
  • Can accurantely determine the temporary fault,transient fault,permanent fault,grounding fault
  • A current greater than or equal to 5A,no external power supply
  • Solar electric,CT electric,a built-in 3.2V lithium iron phosphate battery and a main 3.6V liyhium battery bottom and a super capacitor

Product Image

SNV-308 Overhead Line Earth And Short-circuit Fault Indicator 1
Img 1
SNV-308 Overhead Line Earth And Short-circuit Fault Indicator 2
Img 2
SNV-308 Overhead Line Earth And Short-circuit Fault Indicator 3
Img 3
SNV-308 Overhead Line Earth And Short-circuit Fault Indicator 4
Img 4

Send Inquiry to this Member

Zhuhai SNOVA Electric Technolagy(HongKong)CO.,LTD

Zhuzhou industrial park, Nanping, Xiangzhou District

Phone:
86-0756-8621065
Fax:
86-756-8618303
Contact:
BettyLucy (Sales manager)
Mobile:
13672655807

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Power Distribution Cabinet Made In China Products

,  

Power Distribution Cabinet China Suppliers and China Manufacturers