Product Description

Main Features 

·6 Standard parameters: ECG, RESP, NIBP, SPO2, 2-TEMP, PR/HR.
·12.1"high resolution color TFT LCD display.

·Multilanguage operation softwares,Chinese,English,Turkey,Spain,Russian,French

·Multichannel display 

·Big font interface

·ST and arrhythmia analysis

·Drug dose calculation and titration table

·OxyCRG dynamic view display

·Respiration monitoring with apnea alarms

·Alarm review, arrhythmia review 

·Patient info. Input 

·Antidefibrillation design

·NIBP over pressure protection

·Plugin rechargeable battery, AC/DC available.

·Real time S-T segment analysis, pace-maker detection.
·Indication of Incorrect manipulation and malfunction 
analysis.

·Patient info input management function
·Multi-lead ECG waveforms display in phase.
·Large volume of tabular and graphic trends information 
storage and easy to recall.

·Capture dynamic waveforms.
·Efficient resistance to interference of defibrillator and 
HF knife.

·UP to 2 hours working capacity of built-in rechargeable battery.

·Unique accessory management cabinet.
·Networking capacity.
· Option: 
 Nellcor SpO2, EtCO 2, IBP, Thermal Recorder


Standard configuration


SPO2,PR,NIBP,ECG,RESP,TEMP

Optional configuration

Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
 

Technical Specifications

 

ECG

Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 

Lead selection                     I, II, III, avR, avL, avF, V

Wavef orm                          2 ch

Lead mode                          3 Leads ( R, L, F or RA, LA, LL) 

Lead selection                     I, II, III,

Wave form                          1 ch

Gain                                    2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

 

HR and Alarm Range                 Adult    15 ~ 300 bpm

                                   Neo/Ped    15 ~ 350 bpm

Accuracy                           ±1% or±1bpm, which is greater

Resolution                         1 bpm 

Sensitivity                        > 200 (uVp-p) 

Differential Input Impedance       > 5 MΩ

 

CMRR                   Monitor > 105 dB 

                                   Operation > 105 dB 

                                   Diagnosis > 85 dB

Electrode offset potential         ±300mV 

Leakage Current                    < 10 uA

Baseline Recovery                  < 3 S After Defi. 

ECG Signal Range                   ±8 m V ( Vp-p ) 

 

Bandwidth                           Surgery    1 ~ 20 Hz

                                              Monitor     0.5 ~ 40 Hz

                                               Diagnostic  0.05 ~ 130 Hz

Calibration Signal                  1 (mVp-p),  Accuracy:5%

ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV

 

ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,

                                          PNP, PNC,Alarm Available,Review Available

    

Respiration

Method                           Impedance between R-F(RA-LL)

Differential Input Impedance       > 2.5 MΩ

Measuring Impedance Range          0.3~3 Ω

Base line Impedance Range           200~4 KΩ

Bandwidth                          0.1~2.5Hz

Resp. Rate                         Measuring and Alarm Range

                                    Adult 0 ~ 120 Brpm 

                                    Neo/Ped 0 ~ 150 Brpm 

                                    Resolution 1 Brpm 

                                    Accuracy ±2 Brpm

 

Apnea Alarm                        10 ~ 40 S

 

NIBP 

Method                            Oscillometric

Mode                              Manual, Auto, STAT                        

Measuring Interval in AUTO Mode  1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode     5 Min

Pulse Rate Range          40 ~ 240 bpm

Alarm Type                 SYS, DIA, MEAN

 

Measuring and alarm range        Adult Mode

                                    SYS 40 ~ 270 mmHg 

                                    DIA 10 ~ 215 mmHg 

                                    MEAN 20 ~ 235 mmHg

                                Pediatric Mode

                                    SYS 40 ~ 200 mmHg 

                                    DIA 10 ~ 150 mmHg 

                                    MEAN 20 ~ 165 mmHg

                                Neonatal Mode

                                    SYS 40 ~ 135 mmHg 

                                    DIA 10 ~ 100 mmHg 

                                    MEAN 20 ~ 110 mmHg

Resolution                      1mmHg

 

Accuracy                        Maximum Mean error ±5mmHg

                                Maximum Standard deviation ±8mmHg

Overpressure Protection          Adult Mode 297±3 mmHg 

                                 Pediatric Mode 240±3 mmHg 

                                 Neonatal Mode 147±3 mmHg

 

SpO2

Measuring Range                  0 ~ 100 % 

Alarm Range                      0 ~ 100 % 

Resolution                       1 %

Accuracy                         70% ~ 100%  2 %

                                 0%  ~  69% unspecified

Actualization intervalabout      1 Sec. 

Alarm Delay                      10 Sec.

Pulse Rate                       Measuring and Alarm Range 20~300 bpm

                                 Resolution       1bpm

                                 Accuracy ±3bpm

                                   

TEMP

Channel                          2

Measuring and Alarm Range 0 ~ 50 ºC

Resolution                      0.1 ºC

Accuracy                ±0.1 ºC

Actualization intervalabout     1 Sec.

Average Time Constant           < 10 Sec.

 

 

IBP

Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range       ART 0 ~ 300 mmHg 

                                PA -6 ~ 120 mmHg

                                CVP/RAP/LAP/ICP-10 ~ 40 mmHg

                                P1 / P2-10 ~ 300 mmHg 

    

Press Sensor                    Sensitivity 5  uV/V/mmHg

                                Impedance 300-3000Ω

 

Resolution                      1 mmHg

Accuracy                        ±2% or 1mmHg which is greater

Actualization interval        about 1 secretary

 

Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder

 

Parameters Sheet:

NIBP   Method:Oscillometry
Modes:Manual/Auto/Comtinuous  
Auto measure time:Adjustable
Measurement range:10-300mmHg  
 
ECG  
 
 
 
 
Lead mode: 3-lead or 5-lead
Lead selection: I;II;III,avR;avF;V  
Heart rate range: Adult:15-300bpm;
Pediatric/Neonatal:15-300bpm  
ECG waveform: 2 channals  
Accuracy: ±1 bpm or ±1%,which is greater  
S-T segment detection;measurement range: -2.0mv~+2.0mv  
Alarm:Yes,audible and  visual alarm,alarm events review 
 SPO2 Measurement range:0-100%  
Accuracy:70-100%,±2%,0-69%,upspecified  
Auto measure time:Adjustable  
 
Pulse Rate  
Range:20-254bpm  
Accuracy: ±3bpm  
 
Respiration  
Method:RA-LL impedance  
Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm  
 Apnca alarm:Yes
Temperature   Range:0-500
Accuracy: ± 0.10  
Channal:Dual-channel
 Main unit ECG cable
Spo2 probe
TEM Probe
NIBP Tube
Adult cuff
Power cable
Battery
User manual

 

Product Image

Portable Multi-Parameter Veterinary Monitor Ysd16L-Vet 1
Img 1

Send Inquiry to this Member

Chengdu Yushengda Technology Co.,Ltd

No.39 Jiancai Road Chenghua District,

Phone:
86-028-84193018
Fax:
86-028-84193058
Contact:
Thelma (Export Sales)
Mobile:
84193018

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Personal Care Appliance Made In China Products

,  

Personal Care Appliance China Suppliers and China Manufacturers