Home > Products > Electronics & Electricity > Electronic Instrument > Quantitative Apparatus

SY8125E Single Phase Energy Meter Test BenchEnergy Meter Test Bench auto connect metersenergy meter test bench multi functions
1
  • SY8125E Single Phase Energy Meter Test Bench
  • Energy Meter Test Bench auto connect meters
  • energy meter test bench multi functions

Single Phase Double Channel Energy Meter Test Equipment

Model:SY8126
Brand:SONGYANG
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Quantitative Apparatus
Label:test equipment , energy meter test , meter test equipment
Price: -
Min. Order:1 pc
Inquire Now

Member Information

Detail

HONG KONG SONG YANG INDUSTRIAL LTD.

Biz MemberZhe Jiang - China
Last Online:18 Oct, 2024

Product Description

Introduction  

SY8126 single phase Energy Meter Test Equipment is a new generation, high precision, energy meter calibration equipment. It uses the international’s most advanced technology and components available in 90 decade. The equipment works under the control of keyboard or remote computer.

2 Function

  • Warm up
  • Basic error test
  • Standard deviation (S) in error test
  • Repeatable error test
  • Latent test (no load test)/automatic/manual operation with seek mark automatically
  • Initial test (starting test)/automatic/manual operation with seek mark automatically
  • Voltage influence test
  • Frequency influence test
  • Deviation test for 24 hours
  • Harmonic test
  • Phase circuit testing with close link
  • Neutral circuit testing with close link
  • Neutral missing testing

Technical Specification

  • Accuracy class: 0.02 / 0.05 / 0.1
Accuracy 0.02 Class 0.05 Class   0.1 Class
UPF + 0.02 + 0.05 + 0.10

0.5(lag)

0.8(lead)

+ 0.03 + 0.07 + 0.15
0.5(lead) + 0.04 + 0.10 + 0.20

 

 

       
  • Standard equipment:

 SY3803: Wide current reference standard energy meter,

 Accuracy: Class 0.02 / 0.05 / 0.1

  • Multi secondary voltage transformer (MSVT):

        Primary & Secondary Voltage Ratio: 1:1

        No of secondary outputs: 60 / 48 / 24 / 12 / 6

        Range of secondary burden: 30VA per winding

        Error: < + 0.01%, + 0.3 min, when each secondary load is the same

        Insulation performance:  AC voltage 3kV for 1 minute (between primary and secondary)

  • Output voltage: 

        Voltage range:             30V ~ 300V (Phase – Neutral)

        Measurement error:      0.02% / 0.05%RG  (when connect reference standard)

        Drift per year:             0.05%

          Stability:                                     50ppm/h / 100ppm/h (with integration time of 60seconds)

          Capacity:                           2000VA / 1500VA / 750VA / 250VA

  • Output current::

        Current range:             10mA ~ 120A (Option 20mA ~ 200A)

        Measurement error:      0.02% / 0.05%RD (50mA~120A)  

                                         0.02% / 0.05%RG (10mA~50mA (when connect reference standard)

        Drift per year:               0.05%

          Stability:                                     50ppm/h / 100ppm/h (with integration time of 60seconds)

          Capacity:                           2500VA / 2000VA / 1000VA / 500VA

  • Power factor:

        Power factor range:      -1.000 - 0 - 1.000

        Measurement error:       0.05%RG, PF 0.5-1  (when connect reference standard)

         Drift per year:                 0.05%

  • Frequency range:

        Frequency range:          45 ~ 65Hz (40Hz to 70Hz is optional)

        Measurement error:       0.02%

        Drift per year:                 0.005%

  • Distortion factor: Sinusoidal voltage & current  0.5% (linear load)
  • Harmonic wave output

           2-21 harmonic wave, Contents of Harmonic Wave (Voltage &Current< 40%)

  • Control mode:
    • Keyboard control: LCD menu, fully automatic, manual calibration.
    • Software control: Under Windows 98/2000/XP system, fully automatic, self-definition calibration.
  • Number of meters calibrated: 60 / 48 / 24 / 12 / 6 positions
  • Mains supply voltage : 220V/240V±15% (option 120V), 50/60Hz

                                The maximum power consumption: 3x 5000VA

  • Ambient temperature:

          Storage range:    -200C ~ 550C

          Operating range:  50C ~ 400C

          Specified range:  100C ~ 300C

          Temperature co-efficient:  0.01% / 0C

          Relative Humidity: ≤85%

 

[Details]

 

 

 

 

 


Product Image

SY8125E Single Phase Energy Meter Test Bench
Img 1
Energy Meter Test Bench auto connect meters
Img 2
energy meter test bench multi functions
Img 3

Send Inquiry to this Member

HONG KONG SONG YANG INDUSTRIAL LTD.

Head Office: Room 1507, 15/F., Emperor Group Centre, 288 Hennessy Road, Wanchai, Hong Kong. China Office: 8F, Sunshine Plaza, No.186 Southern Hushu Road, Hangzhou Tel: 0086-571-85391965

Phone:
852-21218691
Fax:
852-21218692
Contact:
David Zhang (Sales manager)
Mobile:
96813088

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Quantitative Apparatus Made In China Products

,  

Quantitative Apparatus China Suppliers and China Manufacturers