Home > Products > Security & Protection > Fire Fighting

4 zones conventional Fire fighting panel with fire alarm and gas extinguishing controllingFire alarm panel diagram for fire engineer4 zones fire alarm panel front view Wire conventional fire alarm conventional fire fighting systemComplete fire alarm system
  • 4 zones conventional Fire fighting panel with fire alarm and gas extinguishing controlling
  • Fire alarm panel diagram for fire engineer
  • 4 zones fire alarm panel front view
  • Wire conventional fire alarm conventional fire fighting system
  • Complete fire alarm system

FIRE ALARM AND GAS EXTINGUISHMENT PANEL

Model:CM1004
Brand:Vedard
Origin:Made In China
Category:Security & Protection / Fire Fighting
Label:Fire fighting panel , Fire alarm panel , Gas extinguish alarm
Price: US $268 / pc
Min. Order:1 pc
Inquire Now Add to Basket

Member Information

Detail

Vedard Tech Co.,Ltd.

Free MemberFu Jian - China
Live Chat:
Last Online:18 Oct, 2020

Product Description

CM1004 is 4 zones conventional Fire fighting panel with fire alarm and gas extinguishing controlling.
The automatic fire extinguish panel is designed in accordance with EN54-2, EN54-4 and EN12094. 
It is a combined fire alarm control panel and extinguishing system with 4 detection zones. 
It can automatically release fire extinguishing and activate solenoid electric valve, extract fan and igniting actuator.
It is with extinguishing release button on alarm panel for manual activate gas extinguishing. 
Panel operation can be enabled or disabled. 
It is with gas leakage pressure detection switch and extinguishing released upon pressure switch operated. 
There are evacuate, silence, Test, reset and extract fan button on panel for operation. 
Two NAC circuits for sounders output and can be enabled and disabled on panel. 
There are relay contacts of fault relay, fire relay, 1st stage alarm, 2nd stage alarm, extract relay. 
Fire fighting gas extinguishing alarm panel
Technical specification:
Size: 383mm W*295mm H *87mm D metal enclosure
Main power supply: 90-270VAC 50Hz/60Hz
Power supply current: 3Amps total including battery charge 28V +/-2V
Battery type: Two 12 volt sealed lead acid in series.
Current draw in post discharge condition with solenoid output active: 0.31Amps
NAC outputs(sounder and bell circuit): 26 -28V DC fused at 500mA with electronic fuse
Number of detectors per zone: <=30 pcs conventional detectors
Number of sounders per circuit: Dependent on type and current consumption
Extinguishing release output: 21V to 28V DC. Maximum load 2Amp
Extinguishing release delay time: Adjustable 0 to 75 seconds
Status unit/ancillary board connection: two wire RS485 connection with electronic fuse 
Max. of 32 units-RS485 data cable


Product Image

4 zones conventional Fire fighting panel with fire alarm and gas extinguishing controlling
Img 1
Fire alarm panel diagram for fire engineer
Img 2
4 zones fire alarm panel front view
Img 3
Wire conventional fire alarm conventional fire fighting system
Img 4
Complete fire alarm system
Img 5

Send Inquiry to this Member

Vedard Tech Co.,Ltd.

No.301, South Yinan, Yiquan St.

Phone:
86-595-22725581
Fax:
86
Contact:
Sarah Huang (Manager)
Mobile:
18650901698

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Fire Fighting Made In China Products

,  

Fire Fighting China Suppliers and China Manufacturers