Home > Products > Electronics & Electricity > Power Supply & Distribution > Power Distribution Cabinet

WMNS Low-voltage Drawable Type Switch Cabinet 1
  • WMNS Low-voltage Drawable Type Switch Cabinet 1

WMNS Low-voltage Drawable Type Switch Cabinet

Model:WMNS
Brand:WORLDSURE
Origin:Made In China
Category:Electronics & Electricity / Power Supply & Distribution / Power Distribution Cabinet
Label:Low-voltage Drawable , Power Distribution , Power Switchgear
Price: US $3000 / pc
Min. Order:1 pc
Inquire Now Add to Basket

Member Information

Detail

Worldwide Electric Stock Co., Ltd

Free MemberHu Bei - China
Live Chat:Last Online:26 Nov, 2014

Product Description

WMNS AC Low Voltage Withdrawable Switchgear

 

General 

  • WMNS is modularized, multi-functional low voltage distribution switchgear, which is applicable to metallurgy, petroleum, chemical industrial, industrial and mining enterprises and all the situations high reliable low voltage system, distribution system and motor control system are needed. 
  • The structure of the cabinet body of WMNS has high flexibility.

The elements of many types and specifications can be installed in the cabinet according to your requirements or different using situations.

The polytype feeder units can be installed in the same list of the cabinet or in the same cabinet according to different electricity equipments. E.g.: the feeding loop and the motor control loop can be wired together.

  • WMNS series low voltage switchgear can meet your need completely. It is applicable to all low voltage systems of the current 4000A or below.
  • WMNS can supply you high level reliability and safety. Its humanized design enhances the protection both for the human body and for the equipments.
  • WMNS is full assembly structure, whose special sectional material and the connection mode as well as the compatibility with the elements can meet the requirements from the working period and the continuity of the power supply.
  • Execution standardIEC60439-1GB7251.1.

 

Type meanings

 W    M    N    S  

                                   

Auxiliary loop scheme no.

                                   Main loop scheme no

                                   Distribution element

                                   Low voltage

Modular 

                                   Worldwide Group

 

. Main technical parameters

3.1 environmental temperature-5~40℃;

3.2 relative humidity 50% when the highest temperature is 40A higher humidity is allowable if the temperature is lower, e.g.: 90% when 20;

3.3 height above sea level2000m

3.4 Inlet and outlet: cables/bus bar bridge;

3.5 cable inlet and outlet: roof/bottom;

3.6 wiring mode: front/back;

3.7 protection degree of the shell: IP30

3.8 Functional unit isolating mode: completely or partly;  

3.9 cabinet height2200

3.10 cabinet width6008001000

3.11 cabinet depth8001000

3.12 rated working voltageto AC660V                                                                  

3.13 rated insulating voltageto AC1000V                                                                  

3.14 over voltage kind ;                                                                    

3.15 pollution degree 3;  

3.16 rated frequency50/60Hz;                                                              

3.17 auxiliary loop rated voltageAC380220V/DC220V;

3.18 rated current4000A;

3.19 rated current of the horizontal bus bar4000A;

3.20 rated current of the vertical bus bar20001000A;

3.21 rated short time tolerance current of the horizontal bus bar50/80kA

3.22 rated peak tolerance current of the horizontal bus bar105/176kA;

3.23 rated short time tolerance current of the vertical bus bar50kA;

3.24 rated peak tolerance current of the vertical bus bar105kA;   

3.25 grounding systemTTITTN-STN-C-S                

 

The main features

4.1 For good installation and onsite construction for the equipments, special cable channels with attached corresponding cable fixing units are set in the distribution cabinet.

4.2 Each position of the drawer unit is with accurate location and clear indication. Besides, each position is respectively locked by 3 locks at the most.

4.3 The drawer unit is connected to L type vertical bus bar flexibly, which is easy and reliable. 

4.4 The special sectional material and the connection mode ensure the strength of the cabinet body.

 

Structure and features

5. Area division of the distribution cabinet

According to different function of the area, the distribution cabinet can be divided into 4 separated isolating rooms. 

5.1.1 Horizontal bus room (on the roof or at the bottom of the cabinet).

5.1.2 Vertical bus room (left side at the cabinet back). It is a L type bus bar which is in a totally-enclosed function board. The dynamic stability of the bus bar is ensured and the protection degree of the hot-line parts can up to IP20 after the drawer is drawn out.

5.1.3 Functional unit room (left side in front of the cabinet). Drawer unit or fixed separated unit

5.1.4 Cable room (light side in front of the cabinet when front outlet; left side in front of the cabinet when back outlet).

5.2 The frame 

5.2.1 The frame of the cabinet selects tee bend connection of special C sectional material (modulus is 25mm), which is assembled after fastened by locking screws and high strength screws. Three are many specifications and dimensions of the sectional materials. Different frame can be assembled according to different cabinet type and actual requirements.

5.2.2 The cabinet body is made of cold rolled steel and import A-zinc alloy plates.

5.3 The shell

Many kinds of protection boards can be added to the frame according to the cabinet structure and the actual requirements.

5.3.1 Cabinet front (transparent glass door, ordinary door plate, withdrawable panel, ventilation door).

5.3.2 Cabinet backback open, sealing board at the back of the cabinet installed by the wall, fixed by the screws directly).

5.3.3 Cabinet side: the side board fixed by the screws.

5.3.4 The roof of the cabinet: roof cover (with ventilation holes, match respective bushing according to the cable size when wiring).

5.3.5 The bottom of the cabinet: bottom covers (match respective bushing according to the cable size).

5.3.6 There are integrated isolating boards among the cabinets.

5.4 assembly type of the cabinets

5.4.1 The drawer cabinetMCC

The drawer cabinet is composed of the drawers, cabinet frame and the relative componentsAll the elements are fixing installed in the drawers. There are five specifications of the drawers: 8E/48E/28E16E24EE=25mmThe drawers with the same specifications can exchange with each other.

The rated current of the drawer is up to 630A. Single equipment can match nine 8E drawers and there are 36 loops (8E/4) at the most.

It is mainly applicable to the control loop of the main motor or used for power distribution.

5.4.2 The fixed cabinet

This kind of cabinet is mainly used for inlet cabinet, contact cabinet, capacity compensator, frequency controller and soft starter.

5.4.3 The mix cabinet

The drawer unit and the fixed unit can be mixed assembled in one cabinet. 8E is a unit according to the module. It is applicable to the situation that the distribution loop and the motor control loop both exist.

5.4.4 The fixed isolating cabinet

Each loop unit are isolating with each other. Plug circuit breaker or withdrawable circuit breaker is adopted for the convenient of the maintenance and inspection. It is mainly applicable to the distribution loop or the control loop of the motor of large power.

5.5 The horizontal bus bar

5.5.1 The horizontal bus bar of the switchgear is arranged in the horizontal bus bar isolating room, which can be arranged at the cabinet back or on the roof.

5.5.2 There can be the upper and lower layer when the horizontal bus bar is arranged at the cabinet back.

5.6 The vertical bus bar

5.6.1 The vertical bus bar is arranged in the vertical bus bar room, which is used for the connection between the functional unit and the main bus bar. It is L shape right-angle copper, which can be installed in the special multi-function board of three-phase or four-phase.

5.6.2 The protection is up to IP20 after the drawer unit is taken out.

5.7 The protection conductor

5.7.1 The protection conductor is used for the equipotential connection of the frame. It is composed of the horizontal and vertical conductor inside the cabinet. The vertical conductor is used for the connection between the cable protective conductor and the earth line.

5.7.2 The section of the protective conductor is made of the standard copper line with the relative specification according to the actual current.

5.8 The small control bus bar

5.8.1 The small control bus bar is used for the power supply of the entire control loop, some communication equipments and the field bus.

5.8.2 The small control bus bar can be arranged in the special isolating room, which can be wired throughout the entire system according to the requirement.

5.9 The cable room

5.9.1 The cable room is the special channel of the wiring of the power cables and the control cables, which is in an isolating room in front of or at the back of the cabinet.

5.9.2 There are special primary and secondary wiring terminals and the relative cable built-in fittings.

5.9.3 There are cable outlet bushing on the bottom cover and the roof cover according to the actual cable size and the inlet and outlet wiring mode.

5.9.4 The cable room can be enlarged or minified as the relative module according to the requirements from the user.

 

The functional unit

6.1 The withdrawable functional unit

6.1.1The drawer is composed of the functional units including some mechanical mechanisms which ensure that the drawers have the positions like connection, test, separating and move out position. Different position can be locked by the padlock. Meanwhile, the monitoring, control and human to machine interface can be integrated on the front panel.

6.1.2 Locate the drawer accurately in connection, test, separating and move out positions by the operation handle or large interlock. Each position has a relative label which is easy and visual on the front panel.

6.1.3 When the circuit breaker switches on, the mechanical interlock prevents the drawer from moving to ensure the safety of the drawer.

6.1.4 In the operation process, the panel of the drawer may be needed to open because of the setting or inspection, and the relative unlocking tools can be used.

6.1.5 Each drawer unit is completely independent; the drawers are completely isolated.

6.1.6 The drawer units of the same specification can exchange flexibly

6.1.7 The outlet side and the fixed patchboard are connected directly. The secondary wiring selects special secondary plug-in board for the connection (the unit of the secondary plug-in board 8E/4 is 16-cord for the most and 32-cord for 8E/2 or above).  

6.1.8 Each drawer unit of each specification has a relative inlet/outlet guide track and a roller wheel which guides the inlet/outlet and the location. The roller wheel can save operation strength.

6.1.9 The special three-sectional guide track can not only make the drawer move flexibly, but also make the inspection and maintenance allowable when the drawer is in the frame. 

6.1.10 A pushing mechanism can be added to the drawer of one unit or above according to the height of the unit or the loop current.

6.1.11 The drawer unit is applicable especially to the control loop of the motor. It is optional according to the function and the actual need for the distribution loop.

6.2 The fixed separate functional unit

6.2.1 This kind functional unit not only keeps the advantage of easy operation of the fixed unit, but also has the features of clear separation and reliable isolation of the drawer unit. It is applicable to the distribution loop and the control loop of the motor.

6.2.2 The plug-in elements can be taken out for maintenance. It is unnecessary to power off when replace it. When inspect the equipment, take out the relative loop unit and the entire distribution system and other loops will not be effected.

6.2.3 The interlocks between the operation mechanism and the rolling handle on the panel make the door cannot open when the circuit breaker switched on, which ensure the safety of the equipment.

6.2.4 When the equipment is operating, if the setting or inspection of the inner elements is necessary, open the panel by the relative unlocking tools.

6.3 The isolating withdrawable unit 

6.3.1 The equipment is installed on a drawer basis which has operation, test, open and taken out positions. There are relative state label in each position which can be located.

6.3.2 There are relative position changed indicating in front of the switch when the position changes. The protection degree of each position keeps IP20.

6.3.3 This scheme simplifies the maintenance of the equipment of large power, which is applicable to inlet, contact and distribution loops.

 

Installation dimension

7.1 The fixed cabinet:

width600mm800mm1000mm

depth600mm800mm1000mm

7.2 The withdrawable cabinet:

width600mm800mm900mm1000mm600mm not s ested

depth600mm800mm1000mm600mm not s ested

7.3 The fixed isolating cabinet

width600mm900mm1000mm

depth600mm800mm1000mm


Product Image

WMNS Low-voltage Drawable Type Switch Cabinet 1
Img 1

Send Inquiry to this Member

Worldwide Electric Stock Co., Ltd

No.58, Changzheng Road, Xiangyang City, Hubei Province, China

Phone:
86-710-3400567
Fax:
86-710-3401656
Contact:
Purple (Foreign Trade Manage)
Mobile:
3400567

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Power Distribution Cabinet Made In China Products

,  

Power Distribution Cabinet China Suppliers and China Manufacturers