Model: | 500V300A |
---|---|
Brand: | Neware |
Origin: | Made In China |
Category: | Industrial Supplies / Electrical & Electronic Product Equipment |
Label: | battery analyzer , battery tester , battery testing equi |
Price: |
-
|
Min. Order: | 1 pc |
Live Chat: | Last Online:30 Oct, 2014 |
Description |
Product Specification |
|||
AC Input |
AC 380V±10% 50Hz |
|||
Single-phase Power |
65 |
KW |
||
Single-phase Current |
296 |
A |
||
Input Power |
195 |
KW |
||
Resolution |
1s |
|||
Voltage |
Range |
Charge: 25V~500V Discharge: 25V~500V |
||
Accuracy |
± 1% of FS |
|||
Stability |
± 1% of FS |
|||
Current |
Range |
Charge: 15A~300A Discharge: 15A~300A |
||
Accuracy |
± 1% of FS |
|||
Stability |
± 1% of FS |
|||
Power |
Output Power Per Channel |
150KW |
||
Stability |
±2% of FS |
|||
Time |
Rise Time |
1s (0~Full Range) |
||
Step Time |
≤ (365*24) hours/step |
Time Format 00:00:00 (h:min:s) |
||
Aux
|
Aux Input |
Temperature、Voltage |
||
Temperature Range |
﹣25℃~110℃ |
|||
Temperature Accuracy |
±(1% of reading + 1℃) |
|||
Temperature Resolution |
0.1℃ |
|||
Voltage Range |
10mV~5V |
|||
Voltage Accuracy |
± 0.1% of FS |
|||
Data Acquisition |
Intervals |
Time Interval Δt: (1s~60000s) |
||
Voltage Interval ΔU: (25V~500V) |
||||
Current Interval ΔI: (15A~300A) |
||||
Frequency |
1Hz |
|||
Charge |
Modes of Operation |
CCC, CVC, CC&CVC |
||
End Conditions |
Main Channel: Voltage, Current, Test Time, Capacity |
|||
Aux Channels: Temperature、Voltage |
||||
Discharge |
Modes of Operation |
CCD, CPD |
||
End Conditions |
Main Channel: Voltage, Current, Test Time, Capacity |
|||
Aux Channels: Temperature、Voltage |
||||
Cycle |
Cycles |
1~65535 |
||
Steps |
254 |
|||
Nested Function |
Max three levels of loops |
|||
Protective Function |
Software |
● Power-off data protection |
||
● Off-line Operating |
||||
● Main Channels: user-defined safety (upper and lower) tolerance of current, voltage and delay time |
||||
● User-defined safety (upper and lower) tolerance of temperature and voltage |
||||
Channel Features |
Independent pairs of closed loop for constant current source and constant voltage source |
|||
Energy Regeneration |
Regenerative Discharge Energy to Power Grid |
|||
Channels |
Independent control |
|||
Noise Density |
<;85dB |
|||
Data Management |
MYSQL Database |
|||
Communication Protocol |
TCP/IP |
|||
Export Formats |
EXCEL, TXT, Graph |
|||
Communication Interface |
Ethernet port |
|||
|
||||
Description |
Product Specification |
|||
Number of Channels Per Cabinet |
1 |
|||
Assignable Aux Voltage Per Channel |
Max 248 |
|||
Assignable Aux Voltage Per Channel |
Max 248 |
|||
Dimensions W*D*H (mm) |
1350*733*1800 |