Specifications

Cable for Nuclear Power Station
1good manufacturer with 30 years' experience
2 top qualiy&best price
3 on time delivery
 

Cable for Nuclear Power Station

  Product standard

Enterprise standard (Refer to the regulated requirement specified in RCC-E nuclear island electric equipment and building rule, France)

Application

This product is suitable for power configuration, control, detection, communication and compensated 1E class loop of meters and instruments of nuclear island factory building of nuclear power station.

Product characteristics

  1. Rated voltage (U0/U): 0.6/1kV;
  2. Max.permissible continuous operating temperature of conductor is 90℃, for short circuit (4s) max. conductor temperature is 250℃;
  3. The ambient temperature under installation -10℃~40℃;
  4. The bending radius of cables are recommend as follows at installaton:

Not less than 6 times the diameter of unscreened cable;

Not less than 8 times the diameter of screened cable,

  1. The lowest temperature as installationed:-40℃;
  2. Used time of cable: 50 years;
  3. Especial property of cable:

(1)       The cable can undergo bundling combustion test specified in GB/T18380.3 (IEC332-3);

(2)       The insulation wire core of cable can undergo vertical combustion test specified in GB/T18380.1 (IEC332-1)

(3)       The low smoke property of cable should conforms to the regulations specified in GB/T17651 (IEC61034): light transmittance≥60;

(4)       The low halogen property of cable should conform to the regulations specified in GB/T17650.2(IEC60754-2):pH≥4.3,electrical conductivity<10μs/mm;

  1. Electric property of cable:

(1)       Cable withstand the test of AC 3500V/5min without breakdown,

(2)       Insulation resistance of cable conductor: p20 not more than 0.0172410Ω·mm2/m

(3)       Constant of insulation resistance for cable: K20 not less than 367MΩ·km, K60 not less than 367MΩ·km, K90 not less than 36MΩ·km.

Specifications and Names

1. Power cable of 6kV used for nuclear power station

Type

Designation

Copper core

Aluminum core

WDZA—YJWJ—K3

WDZA—YJS—K3

WDZA—YJLWJ—K3

WDZA —YJLS— K3

XLPE insulated PO sheathed low fume no halogen A class flame retardant for nuclear power station of K3 kind

XLPE insulated PO sheathed low fume no halogen A class flame retardant for nuclear power station of K3 kind

 

Type

Rated Voltage kV

No. of Core

Nom. area Cross—Section area mm2

WDZA—YJWJ—K3

6/10kV

1

120~630

WDZA—YJLWJ—K3

3

35~95

WDZA—YJS—K3

WDZA—YJLS—K3

Note: The cable in above list A kind fire retardant. For B kind or C kind, use B or C to replace A only.

 

2. Power cable of 1000V used for nuclear power station

Type

Designation

WDZA-YJWJ-K3

Copper conductor XLPE insulated PO sheathed low fume no halogen A class flame retardant for nuclear power station of K3 kind

WDZA-YJLS-K3

Al conductor XLPE insulated PO sheathed low fume no halogen A class flame retardant for nuclear power station of K3 kind

WDZA-WJWJ-K3

Copper conductor low fume no halogen flame retardant XLPE insulated PO sheathed low fume no halogen A class flame retardant for nuclear power station of K3 kind

 

Type

Rated Voltage kV

No. of Core

Nom. area Cross-Section area mm2

WDZA-YJWJ-K3,WDZA-YJLWJ-K3

WDZA-WJWJ-K3,WDZA-WJLWJ-K3

WDZA-EWJ-K3,WDZA-ELWJ-K3

WDZA-ES-K3,WDZA-ELS-K3

WDZA-WJS-K3,WDZA-WJLS-K3

WDZA-YJS-K3,WDZA-YJLS-K3

WDZA-SS-K3,WDZA-SLS-K3

0.6/1

1

50~400

2

2.5~70

3

2.5~150

4

2.5~150

3+1

3×35+1×16~3×150+1×70

6

2×16+4×10 2×10+4×6

Note: The cable in above list is A kind fire retardant. For B kind or C kind, use B or C to replace A only.

 

3. Control cable of 1000V used for nuclear power station

Type

Designation

WDZA-KYJWJP-K3

XLPE insulated braid screened PO sheathed low fume no halogen A class flame retardant for nuclear control station of K3 kind

WDZA-KYJSP-K3

XLPE insulated braid screened PO sheathed low fume no halogen A class flame retardant for nuclear control station of K3 kind

 

Type

Rated Voltage kV

No. of Core

Nom. area Cross-Section area mm2

WDZA-KYJWJ-K3,WDZA-KYJWJP-K3

WDZA-KYJWJP2-K3,WDZA-KYJWJP3-K3

WDZA-KYJS-K3,WDZA-KYJSP-K3

WDZA-KYJSP2-K3,WDZA-KYJSP3-K3

WDZA-KSS-K3,WDZA-KSSP-K3

WDZA-KSSP2-K3,WDZA-KSSP3-K3

WDZA-KES-K3,WDZA-KESP-K3

WDZA-KESP2-K3,WDZA-KESP3-K3

WDZA-KWJS-K3,WDZA-KWJSP-K3

WDZA-KWJP2-K3,WDZA-KWJSP3-K3

0.6/1

2-61

0.5

2-61

0.75

2-61

1.0

2-61

1.5

2-48

2.5

2-24

4

2-24

6

2-19

10

Note: The cable in above list is A kind fire retardant. For B kind or C kind, use B or C to replace A only.

 

Main performance

No.

Item

Unit

Norm

Test mean

1

DC resistance of conductor

 

Accord GB3956

GB/T3048.4

2

Constant K of insulation resistance is

at 120℃

 at 90℃

MΩ/km

 

 

3670

3.67

GB/T3048.5

3

Work frequency voltage test electric power cable and control cable for 5 min

kV

3.5

GB/T3048.8

4

Long time heat circulation test

Test time

Test voltage

 

h

kV

 

5000

2

HN33-5-28

5

Fire-retardant characteristics

 

 

 

5.1

Vertical combustion test of insulation line core

Time of supply fire

Burn area of indication

 

 

 

%

Supply fire 15s,stop fire 15s, repeat 5 times

<2.5

IPCEAS-19-81

5.2

Combustion test of bundled cable

Kind of test

Burn length of cable

 

 

 

m

 

 

B

≤2.5

GB/T18380.3

IEC60332-3

5.3

Test of cable smoke concentration

Light transmittance

 

 

%

 

 

≥60

GB/T17651.2

IEC61034

5.4

Causticity of combustion gas of covered material

PH value

Electric conductibility

 

 

 

μs/mm

 

 

≥4.3

≤10

IEC60754

GB/T60754

6

Nuclear environment test (for K1,K2 kind of cable only)

 

 

 

6.1

Thermal ageing test

Test temperature

Duration

 

h

 

135±3

950

GB/T2951.1

6.2

Damp heat test

Damp

Temperature

Duration

 

%

h

 

95

60±2

48

NFC20-504

6.3

Radiation ageing time

Temperature

Accumulated measure

Dosing rate

 

KGY

GY/S

 

70±3

250

0.28±0.14

IEC60544

6.4

Earthquake test

Temperature

D≤40mm

t;40mm

 

 

20

8D

12D

NFC32-021

6.5

Radiation test under LOCA accident (for K1 kind of cable only)

Temperature

Accumulated measure

Dosing rate

 

 

 

KGY

GY/S

 

 

 

70±3

600

0.28±0.14

IEC60544-2

6.6

LOCA test (for K kind of cable only)

 

pass

RCC-E


Product Image

Cable for Nuclear Power Station  1
Img 1

Send Inquiry to this Member

Hebei New Baofeng Wire & Cable Co.,Ltd

Jinan lixia district industrial south road no. 59 fe smartfortune center 3 floor, room 501

Phone:
86-0531-58617867
Fax:
86
Contact:
Yin (foreign trade manage)
Mobile:
58617867

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Power Cable Made In China Products

,  

Power Cable China Suppliers and China Manufacturers