Product Description

Portable Three Phase Reference Meter MCST01C

 

Features

  • With large LCD display which can display all test parameters, vector, harmonics distortion and set parameters, it can test energy meter error by no switching interface.
  • With optical sensor (scanner) to sense energy recorded automatically from calibration LED/LCD,  also sensor with snap switch
  • In-built electronic book can help operation, MMI interface.
  • Can directly test voltage, current, power, phase, frequency and error at the same time, and voltage and current range can auto-switch.
  • Can do real-burden test of 3 phase 4 wire, 3 phase 3 wire and various reactive energy meter (Q90,Q60)
  • With basic wave test mode, can do test of basic wave meter
  • With two energy pulse input port, can test two meters at the same time, also can do test of active and reactive meter at the same time.
  • Can set energy constant
  • With automatically rounding error function according to accuracy class of energy meter.
  • Can test CT ratio, ratio error, angle error and polarity.
  • CT/PT Ratio can be multiplied with meter constant while doing pulse test when necessary
  • Can test temperature and humidity of working conditions
  • Can analyze 0-51st harmonic wave and can test harmonic content, amplitude value and phase, displayed by histogram.
  • Display waveform, with zoom function.
  • Automatically indentify current in-connection mode and no need to set by user
  • Can do energy accumulation (dial test)
  • Colorful vector graphics display to meet customers user habit
  • Can indentify incorrect connection of 3 phase 3 wire, 3 phase 4 wire at worksite.
  • Optional with mini printer for printing test datum at worksite.
  • Can save 1000pcs test records and can upload to PC.  Support RS232 /USB communication.  Also can receive the test plan from PC.
  • Can extend the test:  PT secondary pressure drop, PT secondary load and CT secondary load (optional)
  • Power supply: 240V+/-15%, 50HZ.  Also can choose battery with continuous working 8 hours

 

Display & Resolution

Parameter Displayed:

  • Instantaneous per phase voltage for 4 wire and line voltage for 3 wire
  • Instantaneous phase current
  • Individual and total active (Fundamental+Harmonics) Power/Reactive and Apparent power
  • Instantaneous per phase power factor in lag/lead
  • Instantaneous total three phase power factor lag/lead
  • Instantaneous per phase and total active, reactive, and apparent energy
  • Instantaneous Frequency
  • Phase sequence of voltage and current
  • Time & Date

Resolution:

  • Voltage: 0.00  V 
  • Current:  0.0001(1A), 0.001(5A), 0.01 (100A), 0.1 (1000A)
  • Power factor: 0.001
  • Energy: 00.0000 (can be better)
  • Frequency: 0.001
  • Inst.Load: 0.000(kW/kVAr/Kva)
  • % error resolution: 0.001

 

Technical Index:

  • Accuracy class of voltage, current, active power, active energy(in-built ct): 0.05
  • Accuracy class of reactive & apparent power and energy: 0.1
  • Voltage input:  30V-560V,  automatically switch in 60V、120V、240V、480V
  • Current input: 1mA~120A, automatically switch
  • Phase test range:0.000°~360°(or 0.000°~±180°), resolution:0.001°。

Accuracy:±0.05°(current input>10%Ib)

  • Frequency test:45-65Hz,  resolution: 0.001HZ, 

Accuracy:±0.01Hz。

  • Input energy pulse:TTL, highest frequency≤2MHz。
  • Power factor range: -1.000 to 0 to +1.000
  • Output energy pulse: Rated range is 60KHz when automatic constant; Can set between 1-250000 when manually constant
  • Temperature coefficient:5ppm。
  • Low voltage input resistance:>750KΩ;
  • Current input resistance:<0.05Ω;
  • Input signal frequency:45~65Hz;
  • Accuracy of PT secondary pressure drop PT(90%~110%Un)

Angle error 0.2´;ratio error 0.02%;

  • Accuracy of PT&CT secondary load test: 1.0

                 Test range:

Admittance:1.0~99.99(ms);

                  Resistance:0.1~8(Ω);

  • Power consumption:≤13VA;
  • Working conditions:-10~40℃ , 30~80%RH;
  • Weight:3Kg。

Product Image

Portabel Three Phase Reference Standard Meter  1
Img 1

Send Inquiry to this Member

Zhengzhou Great Electric Co.,Ltd

No.7, YinPing Road, High Tech Development Zone, Zhengzhou, CHINA 450000

Phone:
86-0371-55016101
Fax:
86-0371-55692730
Contact:
tina (sales manager)
Mobile:
18137888995

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Other Electrical & Electronic Made In China Products

,  

Other Electrical & Electronic China Suppliers and China Manufacturers